Cargando…

Comparison of a second-generation trabecular bypass (iStent inject) to ab interno trabeculectomy (Trabectome) by exact matching

PURPOSE: To achieve a highly balanced comparison of trabecular bypass stenting (IS2, iStent inject) with ab interno trabeculectomy (T, Trabectome) by exact matching. METHODS: Fifty-three IS2 eyes were matched to 3446 T eyes. Patients were matched using exact matching by baseline intraocular pressure...

Descripción completa

Detalles Bibliográficos
Autores principales: Al Yousef, Yousef, Strzalkowska, Alicja, Hillenkamp, Jost, Rosentreter, André, Loewen, Nils A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7677264/
https://www.ncbi.nlm.nih.gov/pubmed/32960322
http://dx.doi.org/10.1007/s00417-020-04933-z
_version_ 1783611933110304768
author Al Yousef, Yousef
Strzalkowska, Alicja
Hillenkamp, Jost
Rosentreter, André
Loewen, Nils A.
author_facet Al Yousef, Yousef
Strzalkowska, Alicja
Hillenkamp, Jost
Rosentreter, André
Loewen, Nils A.
author_sort Al Yousef, Yousef
collection PubMed
description PURPOSE: To achieve a highly balanced comparison of trabecular bypass stenting (IS2, iStent inject) with ab interno trabeculectomy (T, Trabectome) by exact matching. METHODS: Fifty-three IS2 eyes were matched to 3446 T eyes. Patients were matched using exact matching by baseline intraocular pressure (IOP), the number of glaucoma medications, and glaucoma type, and using nearest neighbor matching by age. Individuals without a close match were excluded. All surgeries were combined with phacoemulsification. RESULTS: A total of 78 eyes (39 in each group) could be matched as exact pairs with a baseline IOP of 18.3 ± 5.1 mmHg and glaucoma medications of 2.7 ± 1.2 in each. IOP in IS2 was reduced to 14.6 ± 4.2 mmHg at 3 months and in T to a minimum of 13.1 ± 3.2 mmHg at 1 month. In IS2, IOP began to rise again at 6 months, eventually exceeding baseline. At 24 months, IOP in IS2 was 18.8 ± 9.0 mmHg and in T 14.2 ± 3.5 mmHg. IS2 had a higher average IOP than T at all postoperative visits (p < 0.05 at 1, 12, 18 months). Glaucoma medications decreased to 2.0 ± 1.5 in IS2 and to 1.5 ± 1.4 in T. CONCLUSION: T resulted in a larger and sustained IOP reduction compared with IS2 where a rebound occurred after 6 months to slightly above preoperative values. [Image: see text]
format Online
Article
Text
id pubmed-7677264
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-76772642020-11-23 Comparison of a second-generation trabecular bypass (iStent inject) to ab interno trabeculectomy (Trabectome) by exact matching Al Yousef, Yousef Strzalkowska, Alicja Hillenkamp, Jost Rosentreter, André Loewen, Nils A. Graefes Arch Clin Exp Ophthalmol Glaucoma PURPOSE: To achieve a highly balanced comparison of trabecular bypass stenting (IS2, iStent inject) with ab interno trabeculectomy (T, Trabectome) by exact matching. METHODS: Fifty-three IS2 eyes were matched to 3446 T eyes. Patients were matched using exact matching by baseline intraocular pressure (IOP), the number of glaucoma medications, and glaucoma type, and using nearest neighbor matching by age. Individuals without a close match were excluded. All surgeries were combined with phacoemulsification. RESULTS: A total of 78 eyes (39 in each group) could be matched as exact pairs with a baseline IOP of 18.3 ± 5.1 mmHg and glaucoma medications of 2.7 ± 1.2 in each. IOP in IS2 was reduced to 14.6 ± 4.2 mmHg at 3 months and in T to a minimum of 13.1 ± 3.2 mmHg at 1 month. In IS2, IOP began to rise again at 6 months, eventually exceeding baseline. At 24 months, IOP in IS2 was 18.8 ± 9.0 mmHg and in T 14.2 ± 3.5 mmHg. IS2 had a higher average IOP than T at all postoperative visits (p < 0.05 at 1, 12, 18 months). Glaucoma medications decreased to 2.0 ± 1.5 in IS2 and to 1.5 ± 1.4 in T. CONCLUSION: T resulted in a larger and sustained IOP reduction compared with IS2 where a rebound occurred after 6 months to slightly above preoperative values. [Image: see text] Springer Berlin Heidelberg 2020-09-22 2020 /pmc/articles/PMC7677264/ /pubmed/32960322 http://dx.doi.org/10.1007/s00417-020-04933-z Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Glaucoma
Al Yousef, Yousef
Strzalkowska, Alicja
Hillenkamp, Jost
Rosentreter, André
Loewen, Nils A.
Comparison of a second-generation trabecular bypass (iStent inject) to ab interno trabeculectomy (Trabectome) by exact matching
title Comparison of a second-generation trabecular bypass (iStent inject) to ab interno trabeculectomy (Trabectome) by exact matching
title_full Comparison of a second-generation trabecular bypass (iStent inject) to ab interno trabeculectomy (Trabectome) by exact matching
title_fullStr Comparison of a second-generation trabecular bypass (iStent inject) to ab interno trabeculectomy (Trabectome) by exact matching
title_full_unstemmed Comparison of a second-generation trabecular bypass (iStent inject) to ab interno trabeculectomy (Trabectome) by exact matching
title_short Comparison of a second-generation trabecular bypass (iStent inject) to ab interno trabeculectomy (Trabectome) by exact matching
title_sort comparison of a second-generation trabecular bypass (istent inject) to ab interno trabeculectomy (trabectome) by exact matching
topic Glaucoma
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7677264/
https://www.ncbi.nlm.nih.gov/pubmed/32960322
http://dx.doi.org/10.1007/s00417-020-04933-z
work_keys_str_mv AT alyousefyousef comparisonofasecondgenerationtrabecularbypassistentinjecttoabinternotrabeculectomytrabectomebyexactmatching
AT strzalkowskaalicja comparisonofasecondgenerationtrabecularbypassistentinjecttoabinternotrabeculectomytrabectomebyexactmatching
AT hillenkampjost comparisonofasecondgenerationtrabecularbypassistentinjecttoabinternotrabeculectomytrabectomebyexactmatching
AT rosentreterandre comparisonofasecondgenerationtrabecularbypassistentinjecttoabinternotrabeculectomytrabectomebyexactmatching
AT loewennilsa comparisonofasecondgenerationtrabecularbypassistentinjecttoabinternotrabeculectomytrabectomebyexactmatching