Cargando…

Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis

The present study aimed to compare the imaging performance of two ultra-wide-field fluorescein angiography imaging systems, namely the OptosOptomap 200Tx (Optos 200Tx) and the Heidelberg Spectralis (Spectralis). A total of 18 patients (36 eyes) underwent angiography using the two systems at the Depar...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Shuang, Wang, Jing-Jing, Li, Hong-Yang, Wang, Wei, Tian, Meng, Lang, Xu-Qiang, Wang, Kang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7678619/
https://www.ncbi.nlm.nih.gov/pubmed/33235628
http://dx.doi.org/10.3892/etm.2020.9451
_version_ 1783612194688073728
author Li, Shuang
Wang, Jing-Jing
Li, Hong-Yang
Wang, Wei
Tian, Meng
Lang, Xu-Qiang
Wang, Kang
author_facet Li, Shuang
Wang, Jing-Jing
Li, Hong-Yang
Wang, Wei
Tian, Meng
Lang, Xu-Qiang
Wang, Kang
author_sort Li, Shuang
collection PubMed
description The present study aimed to compare the imaging performance of two ultra-wide-field fluorescein angiography imaging systems, namely the OptosOptomap 200Tx (Optos 200Tx) and the Heidelberg Spectralis (Spectralis). A total of 18 patients (36 eyes) underwent angiography using the two systems at the Department of Ophthalmology, Beijing Friendship Hospital (Beijing, China) between January and June 2017. The images were obtained as a single shot centered on the macula. The total area and area within each of four visualized quadrants were calculated and compared. The averages of the total and individual quadrant area captured by the Optos 200Tx were all larger than those obtained with the Spectralis (P<0.05). For pair-wise comparison, the circular area centered on the macula (radius of 10 and 15 mm) was displayed: Optos 200Tx 10 mm (295.57 mm(2)) < Spectralis (520.11 mm(2)) < Optos 200Tx 15 mm (596.45 mm(2)) < Optos 200Tx (804.36 mm(2)) (P<0.01). The differences of each of the four quadrant areas were statistically significant between the two systems (P<0.05). The mean size of the areas was in the following order: Inferior < temporal < superior < nasal for the Optos 200Tx, and inferior < temporal < nasal < superior for the Spectralis. Further comparison of the four-quadrant area indicated that the inferior quadrant of the Optos 200Tx was smaller than the other three quadrants (P<0.01) and the inferior quadrant of the Spectralis was smaller than the superior quadrant (P<0.01). The total retinal area and the retinal area of each quadrant captured by the Optos 200Tx were larger than those captured with the Spectralis. The total retinal area captured with the Optos 200Tx was able to cover the mid-peripheral area and part of the far-peripheral area of the retina, whereas the Spectralis only covered the mid-peripheral area.
format Online
Article
Text
id pubmed-7678619
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-76786192020-11-23 Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis Li, Shuang Wang, Jing-Jing Li, Hong-Yang Wang, Wei Tian, Meng Lang, Xu-Qiang Wang, Kang Exp Ther Med Articles The present study aimed to compare the imaging performance of two ultra-wide-field fluorescein angiography imaging systems, namely the OptosOptomap 200Tx (Optos 200Tx) and the Heidelberg Spectralis (Spectralis). A total of 18 patients (36 eyes) underwent angiography using the two systems at the Department of Ophthalmology, Beijing Friendship Hospital (Beijing, China) between January and June 2017. The images were obtained as a single shot centered on the macula. The total area and area within each of four visualized quadrants were calculated and compared. The averages of the total and individual quadrant area captured by the Optos 200Tx were all larger than those obtained with the Spectralis (P<0.05). For pair-wise comparison, the circular area centered on the macula (radius of 10 and 15 mm) was displayed: Optos 200Tx 10 mm (295.57 mm(2)) < Spectralis (520.11 mm(2)) < Optos 200Tx 15 mm (596.45 mm(2)) < Optos 200Tx (804.36 mm(2)) (P<0.01). The differences of each of the four quadrant areas were statistically significant between the two systems (P<0.05). The mean size of the areas was in the following order: Inferior < temporal < superior < nasal for the Optos 200Tx, and inferior < temporal < nasal < superior for the Spectralis. Further comparison of the four-quadrant area indicated that the inferior quadrant of the Optos 200Tx was smaller than the other three quadrants (P<0.01) and the inferior quadrant of the Spectralis was smaller than the superior quadrant (P<0.01). The total retinal area and the retinal area of each quadrant captured by the Optos 200Tx were larger than those captured with the Spectralis. The total retinal area captured with the Optos 200Tx was able to cover the mid-peripheral area and part of the far-peripheral area of the retina, whereas the Spectralis only covered the mid-peripheral area. D.A. Spandidos 2021-01 2020-11-05 /pmc/articles/PMC7678619/ /pubmed/33235628 http://dx.doi.org/10.3892/etm.2020.9451 Text en Copyright: © Li et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Li, Shuang
Wang, Jing-Jing
Li, Hong-Yang
Wang, Wei
Tian, Meng
Lang, Xu-Qiang
Wang, Kang
Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis
title Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis
title_full Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis
title_fullStr Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis
title_full_unstemmed Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis
title_short Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis
title_sort performance evaluation of two fundus oculi angiographic imaging system: optos 200tx and heidelberg spectralis
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7678619/
https://www.ncbi.nlm.nih.gov/pubmed/33235628
http://dx.doi.org/10.3892/etm.2020.9451
work_keys_str_mv AT lishuang performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis
AT wangjingjing performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis
AT lihongyang performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis
AT wangwei performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis
AT tianmeng performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis
AT langxuqiang performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis
AT wangkang performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis