Cargando…
Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis
The present study aimed to compare the imaging performance of two ultra-wide-field fluorescein angiography imaging systems, namely the OptosOptomap 200Tx (Optos 200Tx) and the Heidelberg Spectralis (Spectralis). A total of 18 patients (36 eyes) underwent angiography using the two systems at the Depar...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
D.A. Spandidos
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7678619/ https://www.ncbi.nlm.nih.gov/pubmed/33235628 http://dx.doi.org/10.3892/etm.2020.9451 |
_version_ | 1783612194688073728 |
---|---|
author | Li, Shuang Wang, Jing-Jing Li, Hong-Yang Wang, Wei Tian, Meng Lang, Xu-Qiang Wang, Kang |
author_facet | Li, Shuang Wang, Jing-Jing Li, Hong-Yang Wang, Wei Tian, Meng Lang, Xu-Qiang Wang, Kang |
author_sort | Li, Shuang |
collection | PubMed |
description | The present study aimed to compare the imaging performance of two ultra-wide-field fluorescein angiography imaging systems, namely the OptosOptomap 200Tx (Optos 200Tx) and the Heidelberg Spectralis (Spectralis). A total of 18 patients (36 eyes) underwent angiography using the two systems at the Department of Ophthalmology, Beijing Friendship Hospital (Beijing, China) between January and June 2017. The images were obtained as a single shot centered on the macula. The total area and area within each of four visualized quadrants were calculated and compared. The averages of the total and individual quadrant area captured by the Optos 200Tx were all larger than those obtained with the Spectralis (P<0.05). For pair-wise comparison, the circular area centered on the macula (radius of 10 and 15 mm) was displayed: Optos 200Tx 10 mm (295.57 mm(2)) < Spectralis (520.11 mm(2)) < Optos 200Tx 15 mm (596.45 mm(2)) < Optos 200Tx (804.36 mm(2)) (P<0.01). The differences of each of the four quadrant areas were statistically significant between the two systems (P<0.05). The mean size of the areas was in the following order: Inferior < temporal < superior < nasal for the Optos 200Tx, and inferior < temporal < nasal < superior for the Spectralis. Further comparison of the four-quadrant area indicated that the inferior quadrant of the Optos 200Tx was smaller than the other three quadrants (P<0.01) and the inferior quadrant of the Spectralis was smaller than the superior quadrant (P<0.01). The total retinal area and the retinal area of each quadrant captured by the Optos 200Tx were larger than those captured with the Spectralis. The total retinal area captured with the Optos 200Tx was able to cover the mid-peripheral area and part of the far-peripheral area of the retina, whereas the Spectralis only covered the mid-peripheral area. |
format | Online Article Text |
id | pubmed-7678619 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | D.A. Spandidos |
record_format | MEDLINE/PubMed |
spelling | pubmed-76786192020-11-23 Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis Li, Shuang Wang, Jing-Jing Li, Hong-Yang Wang, Wei Tian, Meng Lang, Xu-Qiang Wang, Kang Exp Ther Med Articles The present study aimed to compare the imaging performance of two ultra-wide-field fluorescein angiography imaging systems, namely the OptosOptomap 200Tx (Optos 200Tx) and the Heidelberg Spectralis (Spectralis). A total of 18 patients (36 eyes) underwent angiography using the two systems at the Department of Ophthalmology, Beijing Friendship Hospital (Beijing, China) between January and June 2017. The images were obtained as a single shot centered on the macula. The total area and area within each of four visualized quadrants were calculated and compared. The averages of the total and individual quadrant area captured by the Optos 200Tx were all larger than those obtained with the Spectralis (P<0.05). For pair-wise comparison, the circular area centered on the macula (radius of 10 and 15 mm) was displayed: Optos 200Tx 10 mm (295.57 mm(2)) < Spectralis (520.11 mm(2)) < Optos 200Tx 15 mm (596.45 mm(2)) < Optos 200Tx (804.36 mm(2)) (P<0.01). The differences of each of the four quadrant areas were statistically significant between the two systems (P<0.05). The mean size of the areas was in the following order: Inferior < temporal < superior < nasal for the Optos 200Tx, and inferior < temporal < nasal < superior for the Spectralis. Further comparison of the four-quadrant area indicated that the inferior quadrant of the Optos 200Tx was smaller than the other three quadrants (P<0.01) and the inferior quadrant of the Spectralis was smaller than the superior quadrant (P<0.01). The total retinal area and the retinal area of each quadrant captured by the Optos 200Tx were larger than those captured with the Spectralis. The total retinal area captured with the Optos 200Tx was able to cover the mid-peripheral area and part of the far-peripheral area of the retina, whereas the Spectralis only covered the mid-peripheral area. D.A. Spandidos 2021-01 2020-11-05 /pmc/articles/PMC7678619/ /pubmed/33235628 http://dx.doi.org/10.3892/etm.2020.9451 Text en Copyright: © Li et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. |
spellingShingle | Articles Li, Shuang Wang, Jing-Jing Li, Hong-Yang Wang, Wei Tian, Meng Lang, Xu-Qiang Wang, Kang Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis |
title | Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis |
title_full | Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis |
title_fullStr | Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis |
title_full_unstemmed | Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis |
title_short | Performance evaluation of two fundus oculi angiographic imaging system: Optos 200Tx and Heidelberg Spectralis |
title_sort | performance evaluation of two fundus oculi angiographic imaging system: optos 200tx and heidelberg spectralis |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7678619/ https://www.ncbi.nlm.nih.gov/pubmed/33235628 http://dx.doi.org/10.3892/etm.2020.9451 |
work_keys_str_mv | AT lishuang performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis AT wangjingjing performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis AT lihongyang performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis AT wangwei performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis AT tianmeng performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis AT langxuqiang performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis AT wangkang performanceevaluationoftwofundusoculiangiographicimagingsystemoptos200txandheidelbergspectralis |