Cargando…

A Novel Plate-Based System (UNIMAX) for Posterior Instrumented Spinal Fusion

Introduction The polyaxial head pedicle screw-rod system is a commonly used spinal instrumentation technique to achieve stabilization, deformity correction, and bony fusion. We present a novel plate-based pedicle screw system (UNIMAX(TM)) that can be used for multi-level instrumentation with potenti...

Descripción completa

Detalles Bibliográficos
Autores principales: Pisharodi, Madhavan, Aljuboori, Zaid, Goel, Vijay K, Nauta, Haring J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7678767/
https://www.ncbi.nlm.nih.gov/pubmed/33224674
http://dx.doi.org/10.7759/cureus.11080
Descripción
Sumario:Introduction The polyaxial head pedicle screw-rod system is a commonly used spinal instrumentation technique to achieve stabilization, deformity correction, and bony fusion. We present a novel plate-based pedicle screw system (UNIMAX(TM)) that can be used for multi-level instrumentation with potential advantages for selected applications. Methods Bilateral titanium monoaxial pedicle screws are linked at each level by robust transversely oriented cross plates forming ring constructs capable of rigid triangulation at each level. The cross plates are then interconnected by sagittally oriented rigid plates situated medial to the screw heads. Biomechanically, the construct was tested for quasi-static torsion and fatigue in axial compression. The system is approved by the Food and Drug Administration (FDA). The system and case examples are presented showing its potential advantages. Results The quasi-static torsion, the mean for the angular displacement, torsional stiffness, and torsional ultimate strength was 2.5 degrees (SD ± 0.8), 5.3 N-m/mm (SD ± 0.7), and 21.6 N-m (SD ± 4.4). For the fatigue in axial compression, the closed ring construct failed when the applied load and bending moment were ≥ 1500 N and ≥ 60 N.m. This system maximizes the construct rigidity, allows easy extension to adjacent levels, and can be incorporated intuitively into practice. The ring construct with triangulation at each level, together with its biomechanical robustness, predicts a high pullout resistance. It requires an open posterior approach incompatible with minimally invasive techniques. Conclusion This system may have advantages over the screw-rod systems in carefully selected situations requiring extra rigidity and high pull-out strength for complex reconstructions, sagittal and/or coronal correction, patients with poor bone quality, revisions, and/or extension to adjacent levels.