Cargando…
Automating checks of plan check automation
While a few physicists have designed new plan check automation solutions for their clinics, fewer, if any, managed to adapt existing solutions. As complex and varied as the systems they check, these programs must gain the full confidence of those who would run them on countless patient plans. The pr...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7678958/ https://www.ncbi.nlm.nih.gov/pubmed/25207420 http://dx.doi.org/10.1120/jacmp.v15i4.4889 |
_version_ | 1783612253641113600 |
---|---|
author | Halabi, Tarek Lu, Hsiao‐Ming |
author_facet | Halabi, Tarek Lu, Hsiao‐Ming |
author_sort | Halabi, Tarek |
collection | PubMed |
description | While a few physicists have designed new plan check automation solutions for their clinics, fewer, if any, managed to adapt existing solutions. As complex and varied as the systems they check, these programs must gain the full confidence of those who would run them on countless patient plans. The present automation effort, planCheck, therefore focuses on versatility and ease of implementation and verification. To demonstrate this, we apply planCheck to proton gantry, stereotactic proton gantry, stereotactic proton fixed beam (STAR), and IMRT treatments. PACS numbers: 87.55.km, 87.55.Qr, 87.55.T‐, 89.20.Bp |
format | Online Article Text |
id | pubmed-7678958 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-76789582021-05-25 Automating checks of plan check automation Halabi, Tarek Lu, Hsiao‐Ming J Appl Clin Med Phys Technical Notes While a few physicists have designed new plan check automation solutions for their clinics, fewer, if any, managed to adapt existing solutions. As complex and varied as the systems they check, these programs must gain the full confidence of those who would run them on countless patient plans. The present automation effort, planCheck, therefore focuses on versatility and ease of implementation and verification. To demonstrate this, we apply planCheck to proton gantry, stereotactic proton gantry, stereotactic proton fixed beam (STAR), and IMRT treatments. PACS numbers: 87.55.km, 87.55.Qr, 87.55.T‐, 89.20.Bp John Wiley and Sons Inc. 2014-07-08 /pmc/articles/PMC7678958/ /pubmed/25207420 http://dx.doi.org/10.1120/jacmp.v15i4.4889 Text en © 2014 The Authors. This is an open access article under the terms of the http://creativecommons.org/licenses/by/3.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Technical Notes Halabi, Tarek Lu, Hsiao‐Ming Automating checks of plan check automation |
title | Automating checks of plan check automation |
title_full | Automating checks of plan check automation |
title_fullStr | Automating checks of plan check automation |
title_full_unstemmed | Automating checks of plan check automation |
title_short | Automating checks of plan check automation |
title_sort | automating checks of plan check automation |
topic | Technical Notes |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7678958/ https://www.ncbi.nlm.nih.gov/pubmed/25207420 http://dx.doi.org/10.1120/jacmp.v15i4.4889 |
work_keys_str_mv | AT halabitarek automatingchecksofplancheckautomation AT luhsiaoming automatingchecksofplancheckautomation |