Cargando…
Central Macular Thickness in a Healthy Mexican Population Using Huvitz Optical Coherence Tomography
OBJECTIVE: To determine normal macular thickness values in a healthy Mexican population and its variation by age and gender using Huvitz spectral-domain optical coherence tomography (HOCT-1F). METHODS: This cross-sectional study included 211 consecutive eyes from clinically normal subjects (66 men,...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7680185/ https://www.ncbi.nlm.nih.gov/pubmed/33235432 http://dx.doi.org/10.2147/OPTH.S272431 |
_version_ | 1783612416153616384 |
---|---|
author | García-Franco, Renata Méndez-Marín, Dalia García-Roa, Marlon Ramirez-Neria, Paulina Valera-Cornejo, Diego Lansingh, Van Charles |
author_facet | García-Franco, Renata Méndez-Marín, Dalia García-Roa, Marlon Ramirez-Neria, Paulina Valera-Cornejo, Diego Lansingh, Van Charles |
author_sort | García-Franco, Renata |
collection | PubMed |
description | OBJECTIVE: To determine normal macular thickness values in a healthy Mexican population and its variation by age and gender using Huvitz spectral-domain optical coherence tomography (HOCT-1F). METHODS: This cross-sectional study included 211 consecutive eyes from clinically normal subjects (66 men, 145 women) between October 2018 and December 2018, with best-corrected visual acuities better than 20/30. One eye was selected for the macular scan using the Huvitz OCT (Huvitz OCT-1F, HOCT-1F, Huvitz Co., Ltd., Republic of Korea) with an automated segmentation algorithm. Three vertical and horizontal scans, centered on the fovea with an area of 9 mm, and a color 45° fundus photograph were obtained using Huvitz OCT-1F. Macular measurements were presented as means with standard deviations values for each of the nine regions defined by the Early Treatment Diabetic Retinopathy Study (ETDRS). RESULTS: The mean age was 34.3±11.9 years. Using the ETDRS map, the mean central subfield thickness (CST) was 227.4±18.9 µm. Male gender was associated with greater CST (P<0.001) compared to females. There was no association between mean macular CST (r(2)=0.011; P=0.11) and age. Macular thickness was thicker in the inner ring than in the outer ring, and there were no significant differences in mean CST among age groups (P=0.70). CONCLUSION: Normal macular thickness values using the Huvitz OCT in a Mexican healthy population aged from 18–70 years were thinner in the foveal macular region than values reported in other populations. Female patients had a thinner CST, and age was not correlated with macular thickness. |
format | Online Article Text |
id | pubmed-7680185 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-76801852020-11-23 Central Macular Thickness in a Healthy Mexican Population Using Huvitz Optical Coherence Tomography García-Franco, Renata Méndez-Marín, Dalia García-Roa, Marlon Ramirez-Neria, Paulina Valera-Cornejo, Diego Lansingh, Van Charles Clin Ophthalmol Original Research OBJECTIVE: To determine normal macular thickness values in a healthy Mexican population and its variation by age and gender using Huvitz spectral-domain optical coherence tomography (HOCT-1F). METHODS: This cross-sectional study included 211 consecutive eyes from clinically normal subjects (66 men, 145 women) between October 2018 and December 2018, with best-corrected visual acuities better than 20/30. One eye was selected for the macular scan using the Huvitz OCT (Huvitz OCT-1F, HOCT-1F, Huvitz Co., Ltd., Republic of Korea) with an automated segmentation algorithm. Three vertical and horizontal scans, centered on the fovea with an area of 9 mm, and a color 45° fundus photograph were obtained using Huvitz OCT-1F. Macular measurements were presented as means with standard deviations values for each of the nine regions defined by the Early Treatment Diabetic Retinopathy Study (ETDRS). RESULTS: The mean age was 34.3±11.9 years. Using the ETDRS map, the mean central subfield thickness (CST) was 227.4±18.9 µm. Male gender was associated with greater CST (P<0.001) compared to females. There was no association between mean macular CST (r(2)=0.011; P=0.11) and age. Macular thickness was thicker in the inner ring than in the outer ring, and there were no significant differences in mean CST among age groups (P=0.70). CONCLUSION: Normal macular thickness values using the Huvitz OCT in a Mexican healthy population aged from 18–70 years were thinner in the foveal macular region than values reported in other populations. Female patients had a thinner CST, and age was not correlated with macular thickness. Dove 2020-11-17 /pmc/articles/PMC7680185/ /pubmed/33235432 http://dx.doi.org/10.2147/OPTH.S272431 Text en © 2020 García-Franco et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research García-Franco, Renata Méndez-Marín, Dalia García-Roa, Marlon Ramirez-Neria, Paulina Valera-Cornejo, Diego Lansingh, Van Charles Central Macular Thickness in a Healthy Mexican Population Using Huvitz Optical Coherence Tomography |
title | Central Macular Thickness in a Healthy Mexican Population Using Huvitz Optical Coherence Tomography |
title_full | Central Macular Thickness in a Healthy Mexican Population Using Huvitz Optical Coherence Tomography |
title_fullStr | Central Macular Thickness in a Healthy Mexican Population Using Huvitz Optical Coherence Tomography |
title_full_unstemmed | Central Macular Thickness in a Healthy Mexican Population Using Huvitz Optical Coherence Tomography |
title_short | Central Macular Thickness in a Healthy Mexican Population Using Huvitz Optical Coherence Tomography |
title_sort | central macular thickness in a healthy mexican population using huvitz optical coherence tomography |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7680185/ https://www.ncbi.nlm.nih.gov/pubmed/33235432 http://dx.doi.org/10.2147/OPTH.S272431 |
work_keys_str_mv | AT garciafrancorenata centralmacularthicknessinahealthymexicanpopulationusinghuvitzopticalcoherencetomography AT mendezmarindalia centralmacularthicknessinahealthymexicanpopulationusinghuvitzopticalcoherencetomography AT garciaroamarlon centralmacularthicknessinahealthymexicanpopulationusinghuvitzopticalcoherencetomography AT ramirezneriapaulina centralmacularthicknessinahealthymexicanpopulationusinghuvitzopticalcoherencetomography AT valeracornejodiego centralmacularthicknessinahealthymexicanpopulationusinghuvitzopticalcoherencetomography AT lansinghvancharles centralmacularthicknessinahealthymexicanpopulationusinghuvitzopticalcoherencetomography |