External Cardioversion-Defibrillation with Pushing Down on the Chest Wall to Increase the Success Rate in Obese Patients

Case series Patients: Female, 17-year-old • Male, 63-year-old • Male, 65-year-old Final Diagnosis: Atrial fibrillation Symptoms: Palpitations Medication: — Clinical Procedure: Cardioversion Specialty: Cardiology • Pediatrics and Neonatology OBJECTIVE: Unusual clinical course BACKGROUND: The energy d...

Descripción completa

Detalles Bibliográficos
Autores principales: Young, Ming-Lon, Exelbert, Eric J., Roth, Todd, Cohen, Lance, Cogan, John
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7680710/
https://www.ncbi.nlm.nih.gov/pubmed/33196633
http://dx.doi.org/10.12659/AJCR.927009
_version_ 1783612488027209728
author Young, Ming-Lon
Exelbert, Eric J.
Roth, Todd
Cohen, Lance
Cogan, John
author_facet Young, Ming-Lon
Exelbert, Eric J.
Roth, Todd
Cohen, Lance
Cogan, John
author_sort Young, Ming-Lon
collection PubMed
description Case series Patients: Female, 17-year-old • Male, 63-year-old • Male, 65-year-old Final Diagnosis: Atrial fibrillation Symptoms: Palpitations Medication: — Clinical Procedure: Cardioversion Specialty: Cardiology • Pediatrics and Neonatology OBJECTIVE: Unusual clinical course BACKGROUND: The energy delivered by a defibrillator is expressed in joules (J). However, current is what actually defibrillates the heart and is related to the voltage-to-impedance ratio. With the same energy, the lower the transthoracic impedance, the higher the current delivered. In obese patients, pushing the chest wall toward the heart during electric shock can result in an improved outcome. CASE REPORTS: We report the cases of 3 obese patients with previously failed cardioversion/defibrillation who had an eventual shock success. (1) A 17-year-old girl failed multiple defibrillation efforts for her recurrent ventricular fibrillation. After ECMO, with the physician pushing down the chest wall, a 200-J defibrillation converted her VF. (2) A 63-year-old man with recurrent atrial fibrillation (AF) had an unsuccessful 150-J shock followed by a successful 200-J cardioversion. His AF recurred. After amiodarone bolus, a 200-J shock converted it to sinus. Another recurrent AF failed 150-J cardioversion. With chest pushing down, a 150-J cardioversion was successful. (3) A 65-year-old man underwent elective cardioversion for AF. A 200-J shock was unsuccessful. A 200-J shock with pressure on the chest successfully converted it. CONCLUSIONS: We performed successful electrical cardioversion/defibrillation with this “pushing down the chest while shocking” method. Many clinicians are still unaware of this method, especially in obese patients. With the increasing prevalence of obesity, it is urgent to perform a randomized study to confirm the efficacy and safety of this method, and integrate it into advanced cardiac life support protocols.
format Online
Article
Text
id pubmed-7680710
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-76807102021-01-07 External Cardioversion-Defibrillation with Pushing Down on the Chest Wall to Increase the Success Rate in Obese Patients Young, Ming-Lon Exelbert, Eric J. Roth, Todd Cohen, Lance Cogan, John Am J Case Rep Articles Case series Patients: Female, 17-year-old • Male, 63-year-old • Male, 65-year-old Final Diagnosis: Atrial fibrillation Symptoms: Palpitations Medication: — Clinical Procedure: Cardioversion Specialty: Cardiology • Pediatrics and Neonatology OBJECTIVE: Unusual clinical course BACKGROUND: The energy delivered by a defibrillator is expressed in joules (J). However, current is what actually defibrillates the heart and is related to the voltage-to-impedance ratio. With the same energy, the lower the transthoracic impedance, the higher the current delivered. In obese patients, pushing the chest wall toward the heart during electric shock can result in an improved outcome. CASE REPORTS: We report the cases of 3 obese patients with previously failed cardioversion/defibrillation who had an eventual shock success. (1) A 17-year-old girl failed multiple defibrillation efforts for her recurrent ventricular fibrillation. After ECMO, with the physician pushing down the chest wall, a 200-J defibrillation converted her VF. (2) A 63-year-old man with recurrent atrial fibrillation (AF) had an unsuccessful 150-J shock followed by a successful 200-J cardioversion. His AF recurred. After amiodarone bolus, a 200-J shock converted it to sinus. Another recurrent AF failed 150-J cardioversion. With chest pushing down, a 150-J cardioversion was successful. (3) A 65-year-old man underwent elective cardioversion for AF. A 200-J shock was unsuccessful. A 200-J shock with pressure on the chest successfully converted it. CONCLUSIONS: We performed successful electrical cardioversion/defibrillation with this “pushing down the chest while shocking” method. Many clinicians are still unaware of this method, especially in obese patients. With the increasing prevalence of obesity, it is urgent to perform a randomized study to confirm the efficacy and safety of this method, and integrate it into advanced cardiac life support protocols. International Scientific Literature, Inc. 2020-11-16 /pmc/articles/PMC7680710/ /pubmed/33196633 http://dx.doi.org/10.12659/AJCR.927009 Text en © Am J Case Rep, 2020 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Articles
Young, Ming-Lon
Exelbert, Eric J.
Roth, Todd
Cohen, Lance
Cogan, John
External Cardioversion-Defibrillation with Pushing Down on the Chest Wall to Increase the Success Rate in Obese Patients
title External Cardioversion-Defibrillation with Pushing Down on the Chest Wall to Increase the Success Rate in Obese Patients
title_full External Cardioversion-Defibrillation with Pushing Down on the Chest Wall to Increase the Success Rate in Obese Patients
title_fullStr External Cardioversion-Defibrillation with Pushing Down on the Chest Wall to Increase the Success Rate in Obese Patients
title_full_unstemmed External Cardioversion-Defibrillation with Pushing Down on the Chest Wall to Increase the Success Rate in Obese Patients
title_short External Cardioversion-Defibrillation with Pushing Down on the Chest Wall to Increase the Success Rate in Obese Patients
title_sort external cardioversion-defibrillation with pushing down on the chest wall to increase the success rate in obese patients
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7680710/
https://www.ncbi.nlm.nih.gov/pubmed/33196633
http://dx.doi.org/10.12659/AJCR.927009
work_keys_str_mv AT youngminglon externalcardioversiondefibrillationwithpushingdownonthechestwalltoincreasethesuccessrateinobesepatients
AT exelbertericj externalcardioversiondefibrillationwithpushingdownonthechestwalltoincreasethesuccessrateinobesepatients
AT rothtodd externalcardioversiondefibrillationwithpushingdownonthechestwalltoincreasethesuccessrateinobesepatients
AT cohenlance externalcardioversiondefibrillationwithpushingdownonthechestwalltoincreasethesuccessrateinobesepatients
AT coganjohn externalcardioversiondefibrillationwithpushingdownonthechestwalltoincreasethesuccessrateinobesepatients