Refractive Lens Exchange in Hyperopic Presbyopes with the Acrysof IQ Panoptix Intraocular Lens: One-Year Results and Analysis of the Literature

PURPOSE: To assess the functional and refractive outcomes in hyperopia and presbyopia correction by clear lens exchange with the intraocular trifocal artificial lens (IOL) Acrysof IQ Panoptix implant at 1 year. MATERIALS AND METHODS: A number of 128 eyes (64 patients) underwent clear lens exchange w...

Descripción completa

Detalles Bibliográficos
Autores principales: Nicula, Cristina Ariadna, Popescu, Raluca, Rednik, Anca Maria, Nicula, Dorin, Bulboaca, Adriana Elena, Stanescu, Ioana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7682609/
https://www.ncbi.nlm.nih.gov/pubmed/33239878
http://dx.doi.org/10.2147/TCRM.S279065
_version_ 1783612716957564928
author Nicula, Cristina Ariadna
Popescu, Raluca
Rednik, Anca Maria
Nicula, Dorin
Bulboaca, Adriana Elena
Stanescu, Ioana
author_facet Nicula, Cristina Ariadna
Popescu, Raluca
Rednik, Anca Maria
Nicula, Dorin
Bulboaca, Adriana Elena
Stanescu, Ioana
author_sort Nicula, Cristina Ariadna
collection PubMed
description PURPOSE: To assess the functional and refractive outcomes in hyperopia and presbyopia correction by clear lens exchange with the intraocular trifocal artificial lens (IOL) Acrysof IQ Panoptix implant at 1 year. MATERIALS AND METHODS: A number of 128 eyes (64 patients) underwent clear lens exchange with placement of the trifocal IOL Acrysof IQ Panoptix implant for hyperopia and presbyopia. Prior to the surgery the patients had a complete ocular examination. In all cases the artificial lens was implanted in the bag without any intraoperative complications. Visual acuity (VA) at distance, intermediate and near and ocular refraction were evaluated at 4 weeks, 6 and 12 months postoperatively. RESULTS: The mean age was 53.49 ±7.377 years old (range 40–73 years). As high as 51.57% of the patients were males and 48.43% were females. The mean achieved refraction was 0.26 ± 0.73D. Almost 60.93% of patients were within ±0.25D of the target refraction, with 82.03% eyes within ±0.50D of the planned correction. At 1 year after surgery, 96.45% of eyes had a stable refraction (p >0.05). At 1 year, a total of 92.25%, 89.92% and 91.47% achieved a monocular uncorrected distance, intermediate and near visual acuity of 0.2 logarithm of the minimum angle of resolution or better, respectively. At the same time point, a total of 95.35%, 91.47% and 93.80% achieved a binocular uncorrected distance, intermediate and near visual acuity of 0.2 logarithm of the minimum angle of resolution or better, respectively. There was no statistically significant difference (p>0.05) between the postoperative uncorrected and best corrected VA (distance, intermediate, near) at 6 months and postoperative uncorrected and best corrected VA (distance, intermediate, near) at 12 months. None of our patients had any intraoperative complications. Two cases (1.56%) developed posterior capsule opacification. Twelve patients (18.75%) complained about photic phenomena such as glare and haloes, but this symptom disappeared after 6 months postoperatively. As high as93.56% of patients had a high satisfaction with the outcomes of the surgery. Spectacle independence was obtained in 97.65% eyes. CONCLUSION: The Acrysof Panoptix trifocal artificial lens offers a good vision at distance, intermediate and near, with a good quality of vision and refraction.
format Online
Article
Text
id pubmed-7682609
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-76826092020-11-24 Refractive Lens Exchange in Hyperopic Presbyopes with the Acrysof IQ Panoptix Intraocular Lens: One-Year Results and Analysis of the Literature Nicula, Cristina Ariadna Popescu, Raluca Rednik, Anca Maria Nicula, Dorin Bulboaca, Adriana Elena Stanescu, Ioana Ther Clin Risk Manag Original Research PURPOSE: To assess the functional and refractive outcomes in hyperopia and presbyopia correction by clear lens exchange with the intraocular trifocal artificial lens (IOL) Acrysof IQ Panoptix implant at 1 year. MATERIALS AND METHODS: A number of 128 eyes (64 patients) underwent clear lens exchange with placement of the trifocal IOL Acrysof IQ Panoptix implant for hyperopia and presbyopia. Prior to the surgery the patients had a complete ocular examination. In all cases the artificial lens was implanted in the bag without any intraoperative complications. Visual acuity (VA) at distance, intermediate and near and ocular refraction were evaluated at 4 weeks, 6 and 12 months postoperatively. RESULTS: The mean age was 53.49 ±7.377 years old (range 40–73 years). As high as 51.57% of the patients were males and 48.43% were females. The mean achieved refraction was 0.26 ± 0.73D. Almost 60.93% of patients were within ±0.25D of the target refraction, with 82.03% eyes within ±0.50D of the planned correction. At 1 year after surgery, 96.45% of eyes had a stable refraction (p >0.05). At 1 year, a total of 92.25%, 89.92% and 91.47% achieved a monocular uncorrected distance, intermediate and near visual acuity of 0.2 logarithm of the minimum angle of resolution or better, respectively. At the same time point, a total of 95.35%, 91.47% and 93.80% achieved a binocular uncorrected distance, intermediate and near visual acuity of 0.2 logarithm of the minimum angle of resolution or better, respectively. There was no statistically significant difference (p>0.05) between the postoperative uncorrected and best corrected VA (distance, intermediate, near) at 6 months and postoperative uncorrected and best corrected VA (distance, intermediate, near) at 12 months. None of our patients had any intraoperative complications. Two cases (1.56%) developed posterior capsule opacification. Twelve patients (18.75%) complained about photic phenomena such as glare and haloes, but this symptom disappeared after 6 months postoperatively. As high as93.56% of patients had a high satisfaction with the outcomes of the surgery. Spectacle independence was obtained in 97.65% eyes. CONCLUSION: The Acrysof Panoptix trifocal artificial lens offers a good vision at distance, intermediate and near, with a good quality of vision and refraction. Dove 2020-11-19 /pmc/articles/PMC7682609/ /pubmed/33239878 http://dx.doi.org/10.2147/TCRM.S279065 Text en © 2020 Nicula et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Nicula, Cristina Ariadna
Popescu, Raluca
Rednik, Anca Maria
Nicula, Dorin
Bulboaca, Adriana Elena
Stanescu, Ioana
Refractive Lens Exchange in Hyperopic Presbyopes with the Acrysof IQ Panoptix Intraocular Lens: One-Year Results and Analysis of the Literature
title Refractive Lens Exchange in Hyperopic Presbyopes with the Acrysof IQ Panoptix Intraocular Lens: One-Year Results and Analysis of the Literature
title_full Refractive Lens Exchange in Hyperopic Presbyopes with the Acrysof IQ Panoptix Intraocular Lens: One-Year Results and Analysis of the Literature
title_fullStr Refractive Lens Exchange in Hyperopic Presbyopes with the Acrysof IQ Panoptix Intraocular Lens: One-Year Results and Analysis of the Literature
title_full_unstemmed Refractive Lens Exchange in Hyperopic Presbyopes with the Acrysof IQ Panoptix Intraocular Lens: One-Year Results and Analysis of the Literature
title_short Refractive Lens Exchange in Hyperopic Presbyopes with the Acrysof IQ Panoptix Intraocular Lens: One-Year Results and Analysis of the Literature
title_sort refractive lens exchange in hyperopic presbyopes with the acrysof iq panoptix intraocular lens: one-year results and analysis of the literature
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7682609/
https://www.ncbi.nlm.nih.gov/pubmed/33239878
http://dx.doi.org/10.2147/TCRM.S279065
work_keys_str_mv AT niculacristinaariadna refractivelensexchangeinhyperopicpresbyopeswiththeacrysofiqpanoptixintraocularlensoneyearresultsandanalysisoftheliterature
AT popescuraluca refractivelensexchangeinhyperopicpresbyopeswiththeacrysofiqpanoptixintraocularlensoneyearresultsandanalysisoftheliterature
AT rednikancamaria refractivelensexchangeinhyperopicpresbyopeswiththeacrysofiqpanoptixintraocularlensoneyearresultsandanalysisoftheliterature
AT niculadorin refractivelensexchangeinhyperopicpresbyopeswiththeacrysofiqpanoptixintraocularlensoneyearresultsandanalysisoftheliterature
AT bulboacaadrianaelena refractivelensexchangeinhyperopicpresbyopeswiththeacrysofiqpanoptixintraocularlensoneyearresultsandanalysisoftheliterature
AT stanescuioana refractivelensexchangeinhyperopicpresbyopeswiththeacrysofiqpanoptixintraocularlensoneyearresultsandanalysisoftheliterature