Cargando…

Initial evidence of a 50% reduction of contrast media using digital variance angiography in endovascular carotid interventions

PURPOSE: In previous clinical studies Digital Variance Angiography (DVA) provided higher signal-to-noise ratio (SNR) and better image quality than Digital Subtraction Angiography (DSA). Our aim was to investigate whether this quality reserve of DVA provides an opportunity for the reduction of iodina...

Descripción completa

Detalles Bibliográficos
Autores principales: Óriás, Viktor I., Szöllősi, Dávid, Gyánó, Marcell, Veres, Dániel S., Nardai, Sándor, Csobay-Novák, Csaba, Nemes, Balázs, Kiss, János P, Szigeti, Krisztián, Osváth, Szabolcs, Sótonyi, Péter, Ruzsa, Zoltán
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7683322/
https://www.ncbi.nlm.nih.gov/pubmed/33294499
http://dx.doi.org/10.1016/j.ejro.2020.100288
_version_ 1783612856704434176
author Óriás, Viktor I.
Szöllősi, Dávid
Gyánó, Marcell
Veres, Dániel S.
Nardai, Sándor
Csobay-Novák, Csaba
Nemes, Balázs
Kiss, János P
Szigeti, Krisztián
Osváth, Szabolcs
Sótonyi, Péter
Ruzsa, Zoltán
author_facet Óriás, Viktor I.
Szöllősi, Dávid
Gyánó, Marcell
Veres, Dániel S.
Nardai, Sándor
Csobay-Novák, Csaba
Nemes, Balázs
Kiss, János P
Szigeti, Krisztián
Osváth, Szabolcs
Sótonyi, Péter
Ruzsa, Zoltán
author_sort Óriás, Viktor I.
collection PubMed
description PURPOSE: In previous clinical studies Digital Variance Angiography (DVA) provided higher signal-to-noise ratio (SNR) and better image quality than Digital Subtraction Angiography (DSA). Our aim was to investigate whether this quality reserve of DVA provides an opportunity for the reduction of iodinated contrast media (ICM) in carotid X-ray angiography (CXA). METHOD: Our prospective study enrolled 26 patients (67.0 ± 8.1 years) undergoing carotid percutaneous transluminal angioplasty. The SNR of DSA and DVA image pairs obtained by a standard (100 %, 6 mL ICM) or a low-dose (50 %, 3 mL ICM) protocol were compared. Visual evaluation of all images was performed by five specialists using a 5-grade rating scale. The quality of DSA(100) and DVA(50) videos was also compared. RESULTS: DVA provided more than two-fold SNR, the median SNR(DVA)/SNR(DSA) ratio was 2.06 (100 %) and 2.25 (50 %). In the visual evaluation, the DVA(100) score (3.73 ± 0.06) was significantly higher than the DSA(100) score (3.52 ± 0.07, Wilcoxon p < 0.001), and the DVA(50) score (3.64 ± 0.13) was also significantly higher than the DSA(50) score (3.01 ± 0.17, Wilcoxon p < 0.001). While the low-dose protocol significantly decreased the DSA score (Mann-Whitney p < 0.01, DSA(100) vs DSA(50)), it had no effect on the DVA score (DVA(100) vs DVA(50)). There was no statistical difference between the DSA(100) and DVA(50) scores. Evaluators preferred the diagnostic value of DVA(50) to DSA(100) videos in 61% of comparisons, the interrater agreement was 69 % (Fleiss’ kappa 0.35, p < 0.001) CONCLUSIONS: Our data show that DVA allows a substantial (50 %) ICM reduction in CXA without affecting the quality and diagnostic value of angiograms.
format Online
Article
Text
id pubmed-7683322
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-76833222020-12-07 Initial evidence of a 50% reduction of contrast media using digital variance angiography in endovascular carotid interventions Óriás, Viktor I. Szöllősi, Dávid Gyánó, Marcell Veres, Dániel S. Nardai, Sándor Csobay-Novák, Csaba Nemes, Balázs Kiss, János P Szigeti, Krisztián Osváth, Szabolcs Sótonyi, Péter Ruzsa, Zoltán Eur J Radiol Open Article PURPOSE: In previous clinical studies Digital Variance Angiography (DVA) provided higher signal-to-noise ratio (SNR) and better image quality than Digital Subtraction Angiography (DSA). Our aim was to investigate whether this quality reserve of DVA provides an opportunity for the reduction of iodinated contrast media (ICM) in carotid X-ray angiography (CXA). METHOD: Our prospective study enrolled 26 patients (67.0 ± 8.1 years) undergoing carotid percutaneous transluminal angioplasty. The SNR of DSA and DVA image pairs obtained by a standard (100 %, 6 mL ICM) or a low-dose (50 %, 3 mL ICM) protocol were compared. Visual evaluation of all images was performed by five specialists using a 5-grade rating scale. The quality of DSA(100) and DVA(50) videos was also compared. RESULTS: DVA provided more than two-fold SNR, the median SNR(DVA)/SNR(DSA) ratio was 2.06 (100 %) and 2.25 (50 %). In the visual evaluation, the DVA(100) score (3.73 ± 0.06) was significantly higher than the DSA(100) score (3.52 ± 0.07, Wilcoxon p < 0.001), and the DVA(50) score (3.64 ± 0.13) was also significantly higher than the DSA(50) score (3.01 ± 0.17, Wilcoxon p < 0.001). While the low-dose protocol significantly decreased the DSA score (Mann-Whitney p < 0.01, DSA(100) vs DSA(50)), it had no effect on the DVA score (DVA(100) vs DVA(50)). There was no statistical difference between the DSA(100) and DVA(50) scores. Evaluators preferred the diagnostic value of DVA(50) to DSA(100) videos in 61% of comparisons, the interrater agreement was 69 % (Fleiss’ kappa 0.35, p < 0.001) CONCLUSIONS: Our data show that DVA allows a substantial (50 %) ICM reduction in CXA without affecting the quality and diagnostic value of angiograms. Elsevier 2020-11-17 /pmc/articles/PMC7683322/ /pubmed/33294499 http://dx.doi.org/10.1016/j.ejro.2020.100288 Text en © 2020 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Óriás, Viktor I.
Szöllősi, Dávid
Gyánó, Marcell
Veres, Dániel S.
Nardai, Sándor
Csobay-Novák, Csaba
Nemes, Balázs
Kiss, János P
Szigeti, Krisztián
Osváth, Szabolcs
Sótonyi, Péter
Ruzsa, Zoltán
Initial evidence of a 50% reduction of contrast media using digital variance angiography in endovascular carotid interventions
title Initial evidence of a 50% reduction of contrast media using digital variance angiography in endovascular carotid interventions
title_full Initial evidence of a 50% reduction of contrast media using digital variance angiography in endovascular carotid interventions
title_fullStr Initial evidence of a 50% reduction of contrast media using digital variance angiography in endovascular carotid interventions
title_full_unstemmed Initial evidence of a 50% reduction of contrast media using digital variance angiography in endovascular carotid interventions
title_short Initial evidence of a 50% reduction of contrast media using digital variance angiography in endovascular carotid interventions
title_sort initial evidence of a 50% reduction of contrast media using digital variance angiography in endovascular carotid interventions
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7683322/
https://www.ncbi.nlm.nih.gov/pubmed/33294499
http://dx.doi.org/10.1016/j.ejro.2020.100288
work_keys_str_mv AT oriasviktori initialevidenceofa50reductionofcontrastmediausingdigitalvarianceangiographyinendovascularcarotidinterventions
AT szollosidavid initialevidenceofa50reductionofcontrastmediausingdigitalvarianceangiographyinendovascularcarotidinterventions
AT gyanomarcell initialevidenceofa50reductionofcontrastmediausingdigitalvarianceangiographyinendovascularcarotidinterventions
AT veresdaniels initialevidenceofa50reductionofcontrastmediausingdigitalvarianceangiographyinendovascularcarotidinterventions
AT nardaisandor initialevidenceofa50reductionofcontrastmediausingdigitalvarianceangiographyinendovascularcarotidinterventions
AT csobaynovakcsaba initialevidenceofa50reductionofcontrastmediausingdigitalvarianceangiographyinendovascularcarotidinterventions
AT nemesbalazs initialevidenceofa50reductionofcontrastmediausingdigitalvarianceangiographyinendovascularcarotidinterventions
AT kissjanosp initialevidenceofa50reductionofcontrastmediausingdigitalvarianceangiographyinendovascularcarotidinterventions
AT szigetikrisztian initialevidenceofa50reductionofcontrastmediausingdigitalvarianceangiographyinendovascularcarotidinterventions
AT osvathszabolcs initialevidenceofa50reductionofcontrastmediausingdigitalvarianceangiographyinendovascularcarotidinterventions
AT sotonyipeter initialevidenceofa50reductionofcontrastmediausingdigitalvarianceangiographyinendovascularcarotidinterventions
AT ruzsazoltan initialevidenceofa50reductionofcontrastmediausingdigitalvarianceangiographyinendovascularcarotidinterventions