OBJECTIVES: The present study aims to evaluate the efficacy and safety of the MANTA vascular closure device (VCD) (Teleflex, Morrisville, NC, USA) in transfemoral transcatheter aortic valve replacement (TF-TAVR). BACKGROUND: To close the femoral artery in TF-TAVR a VCD is the treatment of choice. Da...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bohn Stafleu van Loghum
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7683762/ https://www.ncbi.nlm.nih.gov/pubmed/32720122 http://dx.doi.org/10.1007/s12471-020-01465-3 |
_version_ | 1783612947906428928 |
---|---|
author | Halim, J. Missault, L. Lycke, M. Van der Heyden, J. |
author_facet | Halim, J. Missault, L. Lycke, M. Van der Heyden, J. |
author_sort | Halim, J. |
collection | PubMed |
description | OBJECTIVES: The present study aims to evaluate the efficacy and safety of the MANTA vascular closure device (VCD) (Teleflex, Morrisville, NC, USA) in transfemoral transcatheter aortic valve replacement (TF-TAVR). BACKGROUND: To close the femoral artery in TF-TAVR a VCD is the treatment of choice. Data involving suture-based VCDs have been extensive. Although scarce, results on the MANTA device are promising. There is no consensus yet as to whether the MANTA device is associated with fewer access-site-related vascular/bleeding complications when compared to suture-based VCDs. METHODS: In this prospective single-arm study, performed at a single centre, a total of 73 patients eligible for TF-TAVR were included and consecutively treated with the MANTA device. RESULTS: Access-site-related vascular complications were seen in 13.7% of patients treated with the MANTA device. In this group of patients only minor vascular complications were observed. Access-site-related bleeding complications were rare (6.8%), and device failure was seen in 13.7% of the patients. CONCLUSIONS: This single-centre study confirms that use of the MANTA device in TF-TAVR is feasible with an acceptable rate of access-site-related complications and no major vascular complications. |
format | Online Article Text |
id | pubmed-7683762 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Bohn Stafleu van Loghum |
record_format | MEDLINE/PubMed |
spelling | pubmed-76837622020-11-30 Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study Halim, J. Missault, L. Lycke, M. Van der Heyden, J. Neth Heart J Original Article OBJECTIVES: The present study aims to evaluate the efficacy and safety of the MANTA vascular closure device (VCD) (Teleflex, Morrisville, NC, USA) in transfemoral transcatheter aortic valve replacement (TF-TAVR). BACKGROUND: To close the femoral artery in TF-TAVR a VCD is the treatment of choice. Data involving suture-based VCDs have been extensive. Although scarce, results on the MANTA device are promising. There is no consensus yet as to whether the MANTA device is associated with fewer access-site-related vascular/bleeding complications when compared to suture-based VCDs. METHODS: In this prospective single-arm study, performed at a single centre, a total of 73 patients eligible for TF-TAVR were included and consecutively treated with the MANTA device. RESULTS: Access-site-related vascular complications were seen in 13.7% of patients treated with the MANTA device. In this group of patients only minor vascular complications were observed. Access-site-related bleeding complications were rare (6.8%), and device failure was seen in 13.7% of the patients. CONCLUSIONS: This single-centre study confirms that use of the MANTA device in TF-TAVR is feasible with an acceptable rate of access-site-related complications and no major vascular complications. Bohn Stafleu van Loghum 2020-07-27 2020-12 /pmc/articles/PMC7683762/ /pubmed/32720122 http://dx.doi.org/10.1007/s12471-020-01465-3 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Original Article Halim, J. Missault, L. Lycke, M. Van der Heyden, J. Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study |
title | Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study |
title_full | Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study |
title_fullStr | Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study |
title_full_unstemmed | Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study |
title_short | Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study |
title_sort | assessment of the manta closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7683762/ https://www.ncbi.nlm.nih.gov/pubmed/32720122 http://dx.doi.org/10.1007/s12471-020-01465-3 |
work_keys_str_mv | AT halimj assessmentofthemantaclosuredeviceintransfemoraltranscatheteraorticvalvereplacementasinglecentreobservationalstudy AT missaultl assessmentofthemantaclosuredeviceintransfemoraltranscatheteraorticvalvereplacementasinglecentreobservationalstudy AT lyckem assessmentofthemantaclosuredeviceintransfemoraltranscatheteraorticvalvereplacementasinglecentreobservationalstudy AT vanderheydenj assessmentofthemantaclosuredeviceintransfemoraltranscatheteraorticvalvereplacementasinglecentreobservationalstudy |