Cargando…

Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study

OBJECTIVES: The present study aims to evaluate the efficacy and safety of the MANTA vascular closure device (VCD) (Teleflex, Morrisville, NC, USA) in transfemoral transcatheter aortic valve replacement (TF-TAVR). BACKGROUND: To close the femoral artery in TF-TAVR a VCD is the treatment of choice. Da...

Descripción completa

Detalles Bibliográficos
Autores principales: Halim, J., Missault, L., Lycke, M., Van der Heyden, J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bohn Stafleu van Loghum 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7683762/
https://www.ncbi.nlm.nih.gov/pubmed/32720122
http://dx.doi.org/10.1007/s12471-020-01465-3
_version_ 1783612947906428928
author Halim, J.
Missault, L.
Lycke, M.
Van der Heyden, J.
author_facet Halim, J.
Missault, L.
Lycke, M.
Van der Heyden, J.
author_sort Halim, J.
collection PubMed
description OBJECTIVES: The present study aims to evaluate the efficacy and safety of the MANTA vascular closure device (VCD) (Teleflex, Morrisville, NC, USA) in transfemoral transcatheter aortic valve replacement (TF-TAVR). BACKGROUND: To close the femoral artery in TF-TAVR a VCD is the treatment of choice. Data involving suture-based VCDs have been extensive. Although scarce, results on the MANTA device are promising. There is no consensus yet as to whether the MANTA device is associated with fewer access-site-related vascular/bleeding complications when compared to suture-based VCDs. METHODS: In this prospective single-arm study, performed at a single centre, a total of 73 patients eligible for TF-TAVR were included and consecutively treated with the MANTA device. RESULTS: Access-site-related vascular complications were seen in 13.7% of patients treated with the MANTA device. In this group of patients only minor vascular complications were observed. Access-site-related bleeding complications were rare (6.8%), and device failure was seen in 13.7% of the patients. CONCLUSIONS: This single-centre study confirms that use of the MANTA device in TF-TAVR is feasible with an acceptable rate of access-site-related complications and no major vascular complications.
format Online
Article
Text
id pubmed-7683762
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Bohn Stafleu van Loghum
record_format MEDLINE/PubMed
spelling pubmed-76837622020-11-30 Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study Halim, J. Missault, L. Lycke, M. Van der Heyden, J. Neth Heart J Original Article OBJECTIVES: The present study aims to evaluate the efficacy and safety of the MANTA vascular closure device (VCD) (Teleflex, Morrisville, NC, USA) in transfemoral transcatheter aortic valve replacement (TF-TAVR). BACKGROUND: To close the femoral artery in TF-TAVR a VCD is the treatment of choice. Data involving suture-based VCDs have been extensive. Although scarce, results on the MANTA device are promising. There is no consensus yet as to whether the MANTA device is associated with fewer access-site-related vascular/bleeding complications when compared to suture-based VCDs. METHODS: In this prospective single-arm study, performed at a single centre, a total of 73 patients eligible for TF-TAVR were included and consecutively treated with the MANTA device. RESULTS: Access-site-related vascular complications were seen in 13.7% of patients treated with the MANTA device. In this group of patients only minor vascular complications were observed. Access-site-related bleeding complications were rare (6.8%), and device failure was seen in 13.7% of the patients. CONCLUSIONS: This single-centre study confirms that use of the MANTA device in TF-TAVR is feasible with an acceptable rate of access-site-related complications and no major vascular complications. Bohn Stafleu van Loghum 2020-07-27 2020-12 /pmc/articles/PMC7683762/ /pubmed/32720122 http://dx.doi.org/10.1007/s12471-020-01465-3 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Original Article
Halim, J.
Missault, L.
Lycke, M.
Van der Heyden, J.
Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study
title Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study
title_full Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study
title_fullStr Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study
title_full_unstemmed Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study
title_short Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study
title_sort assessment of the manta closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7683762/
https://www.ncbi.nlm.nih.gov/pubmed/32720122
http://dx.doi.org/10.1007/s12471-020-01465-3
work_keys_str_mv AT halimj assessmentofthemantaclosuredeviceintransfemoraltranscatheteraorticvalvereplacementasinglecentreobservationalstudy
AT missaultl assessmentofthemantaclosuredeviceintransfemoraltranscatheteraorticvalvereplacementasinglecentreobservationalstudy
AT lyckem assessmentofthemantaclosuredeviceintransfemoraltranscatheteraorticvalvereplacementasinglecentreobservationalstudy
AT vanderheydenj assessmentofthemantaclosuredeviceintransfemoraltranscatheteraorticvalvereplacementasinglecentreobservationalstudy