Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study
OBJECTIVE: The purpose of the study is to assess the method of implant insertion in D3 and D4 bones and influence of insertion torque for achieving better primary implant stability. MATERIALS AND METHODS: A total of 32 specimens (wood blocks) simulating D4 and D3 bone were grouped into 1, 2, 3, and...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7685276/ https://www.ncbi.nlm.nih.gov/pubmed/33282772 http://dx.doi.org/10.4103/jispcd.JISPCD_160_20 |
_version_ | 1783613154869116928 |
---|---|
author | Bandela, Vinod Munagapati, Bharathi Komala, Jayashree Basany, Ram B Patil, Santosh R Kanaparthi, Saraswathi |
author_facet | Bandela, Vinod Munagapati, Bharathi Komala, Jayashree Basany, Ram B Patil, Santosh R Kanaparthi, Saraswathi |
author_sort | Bandela, Vinod |
collection | PubMed |
description | OBJECTIVE: The purpose of the study is to assess the method of implant insertion in D3 and D4 bones and influence of insertion torque for achieving better primary implant stability. MATERIALS AND METHODS: A total of 32 specimens (wood blocks) simulating D4 and D3 bone were grouped into 1, 2, 3, and 4. In groups 1 and 3, the implant and abutment were placed by manual method while in groups 2 and 4 by motor-driven method. The osteotomy site was prepared as per the protocol for soft bone, and implants were placed till the implant platform was in flush with the surface of the block. After achieving a standard insertion torque of 40 N.cm, pullout test was carried out with a universal testing machine and results were analyzed by one-way analysis of variance. RESULTS: An intergroup comparison of peak loads revealed an overall statistically significant difference (P < 0.0001) with a mean of 442.638 N, maximum in group 4 and least (202.963 N) in group 1. The mean elongation break was found to be maximum in group 3 samples (81.67600%) and less in group 4 (37.15113%). Intergroup comparison of Young’s modulus was statistically significant (P < 0.0001) with a mean value found to be minimum among group 1 samples (597.54750 MPa) and maximum in group 2 (1056.76463 MPa). An intergroup comparison of yield points was found to be maximum among group 4 samples (16.17238MPa) and least in group 1 (5.77438MPa). CONCLUSION: The D3 bone sample provided greater primary stability of implant than D4 bone samples, and the motor-driven implant seemed to have improved stability than that placed manually. |
format | Online Article Text |
id | pubmed-7685276 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-76852762020-12-03 Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study Bandela, Vinod Munagapati, Bharathi Komala, Jayashree Basany, Ram B Patil, Santosh R Kanaparthi, Saraswathi J Int Soc Prev Community Dent Original Article OBJECTIVE: The purpose of the study is to assess the method of implant insertion in D3 and D4 bones and influence of insertion torque for achieving better primary implant stability. MATERIALS AND METHODS: A total of 32 specimens (wood blocks) simulating D4 and D3 bone were grouped into 1, 2, 3, and 4. In groups 1 and 3, the implant and abutment were placed by manual method while in groups 2 and 4 by motor-driven method. The osteotomy site was prepared as per the protocol for soft bone, and implants were placed till the implant platform was in flush with the surface of the block. After achieving a standard insertion torque of 40 N.cm, pullout test was carried out with a universal testing machine and results were analyzed by one-way analysis of variance. RESULTS: An intergroup comparison of peak loads revealed an overall statistically significant difference (P < 0.0001) with a mean of 442.638 N, maximum in group 4 and least (202.963 N) in group 1. The mean elongation break was found to be maximum in group 3 samples (81.67600%) and less in group 4 (37.15113%). Intergroup comparison of Young’s modulus was statistically significant (P < 0.0001) with a mean value found to be minimum among group 1 samples (597.54750 MPa) and maximum in group 2 (1056.76463 MPa). An intergroup comparison of yield points was found to be maximum among group 4 samples (16.17238MPa) and least in group 1 (5.77438MPa). CONCLUSION: The D3 bone sample provided greater primary stability of implant than D4 bone samples, and the motor-driven implant seemed to have improved stability than that placed manually. Wolters Kluwer - Medknow 2020-09-28 /pmc/articles/PMC7685276/ /pubmed/33282772 http://dx.doi.org/10.4103/jispcd.JISPCD_160_20 Text en Copyright: © 2020 Journal of International Society of Preventive and Community Dentistry http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Bandela, Vinod Munagapati, Bharathi Komala, Jayashree Basany, Ram B Patil, Santosh R Kanaparthi, Saraswathi Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study |
title | Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study |
title_full | Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study |
title_fullStr | Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study |
title_full_unstemmed | Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study |
title_short | Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study |
title_sort | comparison of primary stability of implants installed by two different methods in d3 and d4 bone types: an in vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7685276/ https://www.ncbi.nlm.nih.gov/pubmed/33282772 http://dx.doi.org/10.4103/jispcd.JISPCD_160_20 |
work_keys_str_mv | AT bandelavinod comparisonofprimarystabilityofimplantsinstalledbytwodifferentmethodsind3andd4bonetypesaninvitrostudy AT munagapatibharathi comparisonofprimarystabilityofimplantsinstalledbytwodifferentmethodsind3andd4bonetypesaninvitrostudy AT komalajayashree comparisonofprimarystabilityofimplantsinstalledbytwodifferentmethodsind3andd4bonetypesaninvitrostudy AT basanyramb comparisonofprimarystabilityofimplantsinstalledbytwodifferentmethodsind3andd4bonetypesaninvitrostudy AT patilsantoshr comparisonofprimarystabilityofimplantsinstalledbytwodifferentmethodsind3andd4bonetypesaninvitrostudy AT kanaparthisaraswathi comparisonofprimarystabilityofimplantsinstalledbytwodifferentmethodsind3andd4bonetypesaninvitrostudy |