Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study

OBJECTIVE: The purpose of the study is to assess the method of implant insertion in D3 and D4 bones and influence of insertion torque for achieving better primary implant stability. MATERIALS AND METHODS: A total of 32 specimens (wood blocks) simulating D4 and D3 bone were grouped into 1, 2, 3, and...

Descripción completa

Detalles Bibliográficos
Autores principales: Bandela, Vinod, Munagapati, Bharathi, Komala, Jayashree, Basany, Ram B, Patil, Santosh R, Kanaparthi, Saraswathi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7685276/
https://www.ncbi.nlm.nih.gov/pubmed/33282772
http://dx.doi.org/10.4103/jispcd.JISPCD_160_20
_version_ 1783613154869116928
author Bandela, Vinod
Munagapati, Bharathi
Komala, Jayashree
Basany, Ram B
Patil, Santosh R
Kanaparthi, Saraswathi
author_facet Bandela, Vinod
Munagapati, Bharathi
Komala, Jayashree
Basany, Ram B
Patil, Santosh R
Kanaparthi, Saraswathi
author_sort Bandela, Vinod
collection PubMed
description OBJECTIVE: The purpose of the study is to assess the method of implant insertion in D3 and D4 bones and influence of insertion torque for achieving better primary implant stability. MATERIALS AND METHODS: A total of 32 specimens (wood blocks) simulating D4 and D3 bone were grouped into 1, 2, 3, and 4. In groups 1 and 3, the implant and abutment were placed by manual method while in groups 2 and 4 by motor-driven method. The osteotomy site was prepared as per the protocol for soft bone, and implants were placed till the implant platform was in flush with the surface of the block. After achieving a standard insertion torque of 40 N.cm, pullout test was carried out with a universal testing machine and results were analyzed by one-way analysis of variance. RESULTS: An intergroup comparison of peak loads revealed an overall statistically significant difference (P < 0.0001) with a mean of 442.638 N, maximum in group 4 and least (202.963 N) in group 1. The mean elongation break was found to be maximum in group 3 samples (81.67600%) and less in group 4 (37.15113%). Intergroup comparison of Young’s modulus was statistically significant (P < 0.0001) with a mean value found to be minimum among group 1 samples (597.54750 MPa) and maximum in group 2 (1056.76463 MPa). An intergroup comparison of yield points was found to be maximum among group 4 samples (16.17238MPa) and least in group 1 (5.77438MPa). CONCLUSION: The D3 bone sample provided greater primary stability of implant than D4 bone samples, and the motor-driven implant seemed to have improved stability than that placed manually.
format Online
Article
Text
id pubmed-7685276
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-76852762020-12-03 Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study Bandela, Vinod Munagapati, Bharathi Komala, Jayashree Basany, Ram B Patil, Santosh R Kanaparthi, Saraswathi J Int Soc Prev Community Dent Original Article OBJECTIVE: The purpose of the study is to assess the method of implant insertion in D3 and D4 bones and influence of insertion torque for achieving better primary implant stability. MATERIALS AND METHODS: A total of 32 specimens (wood blocks) simulating D4 and D3 bone were grouped into 1, 2, 3, and 4. In groups 1 and 3, the implant and abutment were placed by manual method while in groups 2 and 4 by motor-driven method. The osteotomy site was prepared as per the protocol for soft bone, and implants were placed till the implant platform was in flush with the surface of the block. After achieving a standard insertion torque of 40 N.cm, pullout test was carried out with a universal testing machine and results were analyzed by one-way analysis of variance. RESULTS: An intergroup comparison of peak loads revealed an overall statistically significant difference (P < 0.0001) with a mean of 442.638 N, maximum in group 4 and least (202.963 N) in group 1. The mean elongation break was found to be maximum in group 3 samples (81.67600%) and less in group 4 (37.15113%). Intergroup comparison of Young’s modulus was statistically significant (P < 0.0001) with a mean value found to be minimum among group 1 samples (597.54750 MPa) and maximum in group 2 (1056.76463 MPa). An intergroup comparison of yield points was found to be maximum among group 4 samples (16.17238MPa) and least in group 1 (5.77438MPa). CONCLUSION: The D3 bone sample provided greater primary stability of implant than D4 bone samples, and the motor-driven implant seemed to have improved stability than that placed manually. Wolters Kluwer - Medknow 2020-09-28 /pmc/articles/PMC7685276/ /pubmed/33282772 http://dx.doi.org/10.4103/jispcd.JISPCD_160_20 Text en Copyright: © 2020 Journal of International Society of Preventive and Community Dentistry http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Bandela, Vinod
Munagapati, Bharathi
Komala, Jayashree
Basany, Ram B
Patil, Santosh R
Kanaparthi, Saraswathi
Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study
title Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study
title_full Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study
title_fullStr Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study
title_full_unstemmed Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study
title_short Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An In Vitro Study
title_sort comparison of primary stability of implants installed by two different methods in d3 and d4 bone types: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7685276/
https://www.ncbi.nlm.nih.gov/pubmed/33282772
http://dx.doi.org/10.4103/jispcd.JISPCD_160_20
work_keys_str_mv AT bandelavinod comparisonofprimarystabilityofimplantsinstalledbytwodifferentmethodsind3andd4bonetypesaninvitrostudy
AT munagapatibharathi comparisonofprimarystabilityofimplantsinstalledbytwodifferentmethodsind3andd4bonetypesaninvitrostudy
AT komalajayashree comparisonofprimarystabilityofimplantsinstalledbytwodifferentmethodsind3andd4bonetypesaninvitrostudy
AT basanyramb comparisonofprimarystabilityofimplantsinstalledbytwodifferentmethodsind3andd4bonetypesaninvitrostudy
AT patilsantoshr comparisonofprimarystabilityofimplantsinstalledbytwodifferentmethodsind3andd4bonetypesaninvitrostudy
AT kanaparthisaraswathi comparisonofprimarystabilityofimplantsinstalledbytwodifferentmethodsind3andd4bonetypesaninvitrostudy