Evaluation of negative pressure transfer through tissue in a benchtop cornea and eyelid model

PURPOSE: A new glaucoma treatment device, known as the multi-pressure dial (MPD), has been introduced, which offers a novel approach to IOP reduction by delivering negative pressure to the periocular region. Clinical studies have demonstrated the IOP-lowering effect of the MPD via direct measurement...

Descripción completa

Detalles Bibliográficos
Autores principales: Chu, Nathan, Brambilla, Enrico, Yoo, Paul, Ferguson, Tanner J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7686603/
https://www.ncbi.nlm.nih.gov/pubmed/33283154
http://dx.doi.org/10.1177/2515841420971406
_version_ 1783613361550786560
author Chu, Nathan
Brambilla, Enrico
Yoo, Paul
Ferguson, Tanner J.
author_facet Chu, Nathan
Brambilla, Enrico
Yoo, Paul
Ferguson, Tanner J.
author_sort Chu, Nathan
collection PubMed
description PURPOSE: A new glaucoma treatment device, known as the multi-pressure dial (MPD), has been introduced, which offers a novel approach to IOP reduction by delivering negative pressure to the periocular region. Clinical studies have demonstrated the IOP-lowering effect of the MPD via direct measurements using pneumatonometry. It remains unclear whether the eyelids, when closed, affect the transmission of negative pressure and subsequently affect IOP reduction. This study aimed to evaluate whether the transfer of negative pressure and subsequent decrease in IOP are altered by the presence of synthetic eyelid tissue. METHODS: A model with 13 different configurations controlling for eyelid material type, presence of slit/opening, and eyelid–cornea contact was employed. The slit modification was employed to mimic the physiologic separation that exists between the eyelids. Baseline IOP within an eye model was set at various levels ranging from 10 to 30 mmHg with applied negative pressure settings of 10, 15, and 20 mmHg utilized at each baseline IOP. The percentage of vacuum transfer was calculated by comparing baseline IOP to resultant IOP measurements following application of vacuum to the system. RESULTS: In the open configuration (without eyelid tissue), the mean % vacuum transfer was 98.7%. The sealed, full-contact configurations exhibited values of 97.4%, 98.8%, and 97.2%. The slit configurations, which closely mimic the physiologic eyelid, demonstrated a mean % vacuum transfer of 98.7% across all settings. CONCLUSIONS: The impact of eyelid tissue on transfer of negative pressure can be isolated and evaluated. The presence of eyelid tissue has an insignificant impact on the transfer of negative pressure, and the IOP reduction achievable with the MPD would not be altered with the eyelids closed.
format Online
Article
Text
id pubmed-7686603
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-76866032020-12-03 Evaluation of negative pressure transfer through tissue in a benchtop cornea and eyelid model Chu, Nathan Brambilla, Enrico Yoo, Paul Ferguson, Tanner J. Ther Adv Ophthalmol Original Research PURPOSE: A new glaucoma treatment device, known as the multi-pressure dial (MPD), has been introduced, which offers a novel approach to IOP reduction by delivering negative pressure to the periocular region. Clinical studies have demonstrated the IOP-lowering effect of the MPD via direct measurements using pneumatonometry. It remains unclear whether the eyelids, when closed, affect the transmission of negative pressure and subsequently affect IOP reduction. This study aimed to evaluate whether the transfer of negative pressure and subsequent decrease in IOP are altered by the presence of synthetic eyelid tissue. METHODS: A model with 13 different configurations controlling for eyelid material type, presence of slit/opening, and eyelid–cornea contact was employed. The slit modification was employed to mimic the physiologic separation that exists between the eyelids. Baseline IOP within an eye model was set at various levels ranging from 10 to 30 mmHg with applied negative pressure settings of 10, 15, and 20 mmHg utilized at each baseline IOP. The percentage of vacuum transfer was calculated by comparing baseline IOP to resultant IOP measurements following application of vacuum to the system. RESULTS: In the open configuration (without eyelid tissue), the mean % vacuum transfer was 98.7%. The sealed, full-contact configurations exhibited values of 97.4%, 98.8%, and 97.2%. The slit configurations, which closely mimic the physiologic eyelid, demonstrated a mean % vacuum transfer of 98.7% across all settings. CONCLUSIONS: The impact of eyelid tissue on transfer of negative pressure can be isolated and evaluated. The presence of eyelid tissue has an insignificant impact on the transfer of negative pressure, and the IOP reduction achievable with the MPD would not be altered with the eyelids closed. SAGE Publications 2020-11-18 /pmc/articles/PMC7686603/ /pubmed/33283154 http://dx.doi.org/10.1177/2515841420971406 Text en © The Author(s), 2020 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research
Chu, Nathan
Brambilla, Enrico
Yoo, Paul
Ferguson, Tanner J.
Evaluation of negative pressure transfer through tissue in a benchtop cornea and eyelid model
title Evaluation of negative pressure transfer through tissue in a benchtop cornea and eyelid model
title_full Evaluation of negative pressure transfer through tissue in a benchtop cornea and eyelid model
title_fullStr Evaluation of negative pressure transfer through tissue in a benchtop cornea and eyelid model
title_full_unstemmed Evaluation of negative pressure transfer through tissue in a benchtop cornea and eyelid model
title_short Evaluation of negative pressure transfer through tissue in a benchtop cornea and eyelid model
title_sort evaluation of negative pressure transfer through tissue in a benchtop cornea and eyelid model
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7686603/
https://www.ncbi.nlm.nih.gov/pubmed/33283154
http://dx.doi.org/10.1177/2515841420971406
work_keys_str_mv AT chunathan evaluationofnegativepressuretransferthroughtissueinabenchtopcorneaandeyelidmodel
AT brambillaenrico evaluationofnegativepressuretransferthroughtissueinabenchtopcorneaandeyelidmodel
AT yoopaul evaluationofnegativepressuretransferthroughtissueinabenchtopcorneaandeyelidmodel
AT fergusontannerj evaluationofnegativepressuretransferthroughtissueinabenchtopcorneaandeyelidmodel