Cargando…

Iodine-125 seed implantation treatment of lung metastases < 2.5 cm using 5-ml syringe as a guide

PURPOSE: Small lung metastases change their location with respiration, making difficult to localize, therefore, increasing the number of punctures. Accurate puncture can reduce trauma to lung tissue and accelerate patient’s recovery. The aim of the study was to present our experience with the techni...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Jie, Zhang, Lijuan, Sun, Zongqiong, Ge, Yuxi, Zhou, Jialiang, Xie, Qigen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7690223/
https://www.ncbi.nlm.nih.gov/pubmed/33293972
http://dx.doi.org/10.5114/jcb.2020.98112
_version_ 1783614025578315776
author Li, Jie
Zhang, Lijuan
Sun, Zongqiong
Ge, Yuxi
Zhou, Jialiang
Xie, Qigen
author_facet Li, Jie
Zhang, Lijuan
Sun, Zongqiong
Ge, Yuxi
Zhou, Jialiang
Xie, Qigen
author_sort Li, Jie
collection PubMed
description PURPOSE: Small lung metastases change their location with respiration, making difficult to localize, therefore, increasing the number of punctures. Accurate puncture can reduce trauma to lung tissue and accelerate patient’s recovery. The aim of the study was to present our experience with the technique of using local anesthesia 5-ml syringe as a guide for computerized tomography-guided iodine-125 seed implantation (CT-ISI). MATERIAL AND METHODS: This was a retrospective study, including patients with small metastatic tumors in the lung, treated with CT-ISI between December 2013 and March 2018 at the Affiliated Hospital of the University. The patients were divided according to whether a 5-ml syringe was used as a guide during CT-ISI or not. The final follow-up was on March 31(st), 2018. Implantation success and complications were examined. RESULTS: Nineteen patients were included. A total of 840 seeds were used, with 44.2 ±33.6 (range, 10-160) seeds per patient. The mean D(90) for CT-ISI was 134.5 ±7.5 Gy. Treatment intervention for eleven patients was performed using a 5-ml syringe as a guide during CT-ISI. There were no differences in total dose and number of implanted seeds between the two groups, but the number of punctures per lesion was lower in the syringe group than in the no-syringe group (1.9 ±0.5 vs. 2.9 ±0.6, p < 0.001), suggesting a higher puncture accuracy. The total number of SMTIL was 50 (median, 2; range, 1-10), and the median size was 1.9 cm (range, 0.8-2.4 cm). All SMTIL were well-controlled at 6-months follow-up (response rate [RR] = 100%). One patient in the no-syringe group experienced grade 2 chest tightness, chest pain, intraoperative needle tract bleeding, and post-operative blood in sputum. CONCLUSIONS: Puncture with a 5-ml syringe as a guide during CT-ISI seems to be a more accurate option for patients with small (< 2.5 cm) lung metastasis.
format Online
Article
Text
id pubmed-7690223
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-76902232020-12-07 Iodine-125 seed implantation treatment of lung metastases < 2.5 cm using 5-ml syringe as a guide Li, Jie Zhang, Lijuan Sun, Zongqiong Ge, Yuxi Zhou, Jialiang Xie, Qigen J Contemp Brachytherapy Original Paper PURPOSE: Small lung metastases change their location with respiration, making difficult to localize, therefore, increasing the number of punctures. Accurate puncture can reduce trauma to lung tissue and accelerate patient’s recovery. The aim of the study was to present our experience with the technique of using local anesthesia 5-ml syringe as a guide for computerized tomography-guided iodine-125 seed implantation (CT-ISI). MATERIAL AND METHODS: This was a retrospective study, including patients with small metastatic tumors in the lung, treated with CT-ISI between December 2013 and March 2018 at the Affiliated Hospital of the University. The patients were divided according to whether a 5-ml syringe was used as a guide during CT-ISI or not. The final follow-up was on March 31(st), 2018. Implantation success and complications were examined. RESULTS: Nineteen patients were included. A total of 840 seeds were used, with 44.2 ±33.6 (range, 10-160) seeds per patient. The mean D(90) for CT-ISI was 134.5 ±7.5 Gy. Treatment intervention for eleven patients was performed using a 5-ml syringe as a guide during CT-ISI. There were no differences in total dose and number of implanted seeds between the two groups, but the number of punctures per lesion was lower in the syringe group than in the no-syringe group (1.9 ±0.5 vs. 2.9 ±0.6, p < 0.001), suggesting a higher puncture accuracy. The total number of SMTIL was 50 (median, 2; range, 1-10), and the median size was 1.9 cm (range, 0.8-2.4 cm). All SMTIL were well-controlled at 6-months follow-up (response rate [RR] = 100%). One patient in the no-syringe group experienced grade 2 chest tightness, chest pain, intraoperative needle tract bleeding, and post-operative blood in sputum. CONCLUSIONS: Puncture with a 5-ml syringe as a guide during CT-ISI seems to be a more accurate option for patients with small (< 2.5 cm) lung metastasis. Termedia Publishing House 2020-08-21 2020-08 /pmc/articles/PMC7690223/ /pubmed/33293972 http://dx.doi.org/10.5114/jcb.2020.98112 Text en Copyright © 2020 Termedia http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/)
spellingShingle Original Paper
Li, Jie
Zhang, Lijuan
Sun, Zongqiong
Ge, Yuxi
Zhou, Jialiang
Xie, Qigen
Iodine-125 seed implantation treatment of lung metastases < 2.5 cm using 5-ml syringe as a guide
title Iodine-125 seed implantation treatment of lung metastases < 2.5 cm using 5-ml syringe as a guide
title_full Iodine-125 seed implantation treatment of lung metastases < 2.5 cm using 5-ml syringe as a guide
title_fullStr Iodine-125 seed implantation treatment of lung metastases < 2.5 cm using 5-ml syringe as a guide
title_full_unstemmed Iodine-125 seed implantation treatment of lung metastases < 2.5 cm using 5-ml syringe as a guide
title_short Iodine-125 seed implantation treatment of lung metastases < 2.5 cm using 5-ml syringe as a guide
title_sort iodine-125 seed implantation treatment of lung metastases < 2.5 cm using 5-ml syringe as a guide
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7690223/
https://www.ncbi.nlm.nih.gov/pubmed/33293972
http://dx.doi.org/10.5114/jcb.2020.98112
work_keys_str_mv AT lijie iodine125seedimplantationtreatmentoflungmetastases25cmusing5mlsyringeasaguide
AT zhanglijuan iodine125seedimplantationtreatmentoflungmetastases25cmusing5mlsyringeasaguide
AT sunzongqiong iodine125seedimplantationtreatmentoflungmetastases25cmusing5mlsyringeasaguide
AT geyuxi iodine125seedimplantationtreatmentoflungmetastases25cmusing5mlsyringeasaguide
AT zhoujialiang iodine125seedimplantationtreatmentoflungmetastases25cmusing5mlsyringeasaguide
AT xieqigen iodine125seedimplantationtreatmentoflungmetastases25cmusing5mlsyringeasaguide