Cargando…

An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication

The combination of extreme miniaturization with a high sensitivity and the potential to be integrated in an array form on a chip has made silicon-based photonic microring resonators a very attractive research topic. As biosensors are approaching the nanoscale, analyte mass transfer and bonding kinet...

Descripción completa

Detalles Bibliográficos
Autores principales: Henriksson, Anders, Kasper, Laura, Jäger, Matthias, Neubauer, Peter, Birkholz, Mario
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7690605/
https://www.ncbi.nlm.nih.gov/pubmed/33105846
http://dx.doi.org/10.3390/mi11110954
_version_ 1783614106124681216
author Henriksson, Anders
Kasper, Laura
Jäger, Matthias
Neubauer, Peter
Birkholz, Mario
author_facet Henriksson, Anders
Kasper, Laura
Jäger, Matthias
Neubauer, Peter
Birkholz, Mario
author_sort Henriksson, Anders
collection PubMed
description The combination of extreme miniaturization with a high sensitivity and the potential to be integrated in an array form on a chip has made silicon-based photonic microring resonators a very attractive research topic. As biosensors are approaching the nanoscale, analyte mass transfer and bonding kinetics have been ascribed as crucial factors that limit their performance. One solution may be a system that applies dielectrophoretic forces, in addition to microfluidics, to overcome the diffusion limits of conventional biosensors. Dielectrophoresis, which involves the migration of polarized dielectric particles in a non-uniform alternating electric field, has previously been successfully applied to achieve a 1000-fold improved detection efficiency in nanopore sensing and may significantly increase the sensitivity in microring resonator biosensing. In the current work, we designed microring resonators with integrated electrodes next to the sensor surface that may be used to explore the effect of dielectrophoresis. The chip design, including two different electrode configurations, electric field gradient simulations, and the fabrication process flow of a dielectrohoresis-enhanced microring resonator-based sensor, is presented in this paper. Finite element method (FEM) simulations calculated for both electrode configurations revealed ∇E(2) values above 10(17) V(2)m(−3) around the sensing areas. This is comparable to electric field gradients previously reported for successful interactions with larger molecules, such as proteins and antibodies.
format Online
Article
Text
id pubmed-7690605
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76906052020-11-27 An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication Henriksson, Anders Kasper, Laura Jäger, Matthias Neubauer, Peter Birkholz, Mario Micromachines (Basel) Article The combination of extreme miniaturization with a high sensitivity and the potential to be integrated in an array form on a chip has made silicon-based photonic microring resonators a very attractive research topic. As biosensors are approaching the nanoscale, analyte mass transfer and bonding kinetics have been ascribed as crucial factors that limit their performance. One solution may be a system that applies dielectrophoretic forces, in addition to microfluidics, to overcome the diffusion limits of conventional biosensors. Dielectrophoresis, which involves the migration of polarized dielectric particles in a non-uniform alternating electric field, has previously been successfully applied to achieve a 1000-fold improved detection efficiency in nanopore sensing and may significantly increase the sensitivity in microring resonator biosensing. In the current work, we designed microring resonators with integrated electrodes next to the sensor surface that may be used to explore the effect of dielectrophoresis. The chip design, including two different electrode configurations, electric field gradient simulations, and the fabrication process flow of a dielectrohoresis-enhanced microring resonator-based sensor, is presented in this paper. Finite element method (FEM) simulations calculated for both electrode configurations revealed ∇E(2) values above 10(17) V(2)m(−3) around the sensing areas. This is comparable to electric field gradients previously reported for successful interactions with larger molecules, such as proteins and antibodies. MDPI 2020-10-22 /pmc/articles/PMC7690605/ /pubmed/33105846 http://dx.doi.org/10.3390/mi11110954 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Henriksson, Anders
Kasper, Laura
Jäger, Matthias
Neubauer, Peter
Birkholz, Mario
An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication
title An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication
title_full An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication
title_fullStr An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication
title_full_unstemmed An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication
title_short An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication
title_sort approach to ring resonator biosensing assisted by dielectrophoresis: design, simulation and fabrication
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7690605/
https://www.ncbi.nlm.nih.gov/pubmed/33105846
http://dx.doi.org/10.3390/mi11110954
work_keys_str_mv AT henrikssonanders anapproachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication
AT kasperlaura anapproachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication
AT jagermatthias anapproachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication
AT neubauerpeter anapproachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication
AT birkholzmario anapproachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication
AT henrikssonanders approachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication
AT kasperlaura approachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication
AT jagermatthias approachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication
AT neubauerpeter approachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication
AT birkholzmario approachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication