Cargando…
An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication
The combination of extreme miniaturization with a high sensitivity and the potential to be integrated in an array form on a chip has made silicon-based photonic microring resonators a very attractive research topic. As biosensors are approaching the nanoscale, analyte mass transfer and bonding kinet...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7690605/ https://www.ncbi.nlm.nih.gov/pubmed/33105846 http://dx.doi.org/10.3390/mi11110954 |
_version_ | 1783614106124681216 |
---|---|
author | Henriksson, Anders Kasper, Laura Jäger, Matthias Neubauer, Peter Birkholz, Mario |
author_facet | Henriksson, Anders Kasper, Laura Jäger, Matthias Neubauer, Peter Birkholz, Mario |
author_sort | Henriksson, Anders |
collection | PubMed |
description | The combination of extreme miniaturization with a high sensitivity and the potential to be integrated in an array form on a chip has made silicon-based photonic microring resonators a very attractive research topic. As biosensors are approaching the nanoscale, analyte mass transfer and bonding kinetics have been ascribed as crucial factors that limit their performance. One solution may be a system that applies dielectrophoretic forces, in addition to microfluidics, to overcome the diffusion limits of conventional biosensors. Dielectrophoresis, which involves the migration of polarized dielectric particles in a non-uniform alternating electric field, has previously been successfully applied to achieve a 1000-fold improved detection efficiency in nanopore sensing and may significantly increase the sensitivity in microring resonator biosensing. In the current work, we designed microring resonators with integrated electrodes next to the sensor surface that may be used to explore the effect of dielectrophoresis. The chip design, including two different electrode configurations, electric field gradient simulations, and the fabrication process flow of a dielectrohoresis-enhanced microring resonator-based sensor, is presented in this paper. Finite element method (FEM) simulations calculated for both electrode configurations revealed ∇E(2) values above 10(17) V(2)m(−3) around the sensing areas. This is comparable to electric field gradients previously reported for successful interactions with larger molecules, such as proteins and antibodies. |
format | Online Article Text |
id | pubmed-7690605 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-76906052020-11-27 An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication Henriksson, Anders Kasper, Laura Jäger, Matthias Neubauer, Peter Birkholz, Mario Micromachines (Basel) Article The combination of extreme miniaturization with a high sensitivity and the potential to be integrated in an array form on a chip has made silicon-based photonic microring resonators a very attractive research topic. As biosensors are approaching the nanoscale, analyte mass transfer and bonding kinetics have been ascribed as crucial factors that limit their performance. One solution may be a system that applies dielectrophoretic forces, in addition to microfluidics, to overcome the diffusion limits of conventional biosensors. Dielectrophoresis, which involves the migration of polarized dielectric particles in a non-uniform alternating electric field, has previously been successfully applied to achieve a 1000-fold improved detection efficiency in nanopore sensing and may significantly increase the sensitivity in microring resonator biosensing. In the current work, we designed microring resonators with integrated electrodes next to the sensor surface that may be used to explore the effect of dielectrophoresis. The chip design, including two different electrode configurations, electric field gradient simulations, and the fabrication process flow of a dielectrohoresis-enhanced microring resonator-based sensor, is presented in this paper. Finite element method (FEM) simulations calculated for both electrode configurations revealed ∇E(2) values above 10(17) V(2)m(−3) around the sensing areas. This is comparable to electric field gradients previously reported for successful interactions with larger molecules, such as proteins and antibodies. MDPI 2020-10-22 /pmc/articles/PMC7690605/ /pubmed/33105846 http://dx.doi.org/10.3390/mi11110954 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Henriksson, Anders Kasper, Laura Jäger, Matthias Neubauer, Peter Birkholz, Mario An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication |
title | An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication |
title_full | An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication |
title_fullStr | An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication |
title_full_unstemmed | An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication |
title_short | An Approach to Ring Resonator Biosensing Assisted by Dielectrophoresis: Design, Simulation and Fabrication |
title_sort | approach to ring resonator biosensing assisted by dielectrophoresis: design, simulation and fabrication |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7690605/ https://www.ncbi.nlm.nih.gov/pubmed/33105846 http://dx.doi.org/10.3390/mi11110954 |
work_keys_str_mv | AT henrikssonanders anapproachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication AT kasperlaura anapproachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication AT jagermatthias anapproachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication AT neubauerpeter anapproachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication AT birkholzmario anapproachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication AT henrikssonanders approachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication AT kasperlaura approachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication AT jagermatthias approachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication AT neubauerpeter approachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication AT birkholzmario approachtoringresonatorbiosensingassistedbydielectrophoresisdesignsimulationandfabrication |