Cargando…
Effect of Different Bond Parameters on the Mechanical Properties of FRP and Concrete Interface
This paper presents double shear tests performed to investigate factors influencing the bond behavior between basalt fiber-reinforced polymer (BFRP), glass fiber-reinforced polymer (GFRP) laminate, and concrete blocks. In detail, thirty-six twin concrete blocks strengthened with the aforementioned F...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7690919/ https://www.ncbi.nlm.nih.gov/pubmed/33114349 http://dx.doi.org/10.3390/polym12112466 |
_version_ | 1783614178874884096 |
---|---|
author | Mensah, Comfort Wang, Zhenqing Bonsu, Alex Osei Liang, Wenyan |
author_facet | Mensah, Comfort Wang, Zhenqing Bonsu, Alex Osei Liang, Wenyan |
author_sort | Mensah, Comfort |
collection | PubMed |
description | This paper presents double shear tests performed to investigate factors influencing the bond behavior between basalt fiber-reinforced polymer (BFRP), glass fiber-reinforced polymer (GFRP) laminate, and concrete blocks. In detail, thirty-six twin concrete blocks strengthened with the aforementioned FRP types were tested to evaluate the influence of FRP length, width, and thickness, and their bonding behavior. The 2D-DIC (digital image correlation) technique and several strain gauges bonded along the laminate were used to measure the strain distributions of the FRP-to-concrete interface. The failure mode, ultimate load, load–slip, strain distribution, and bond–slip relationships between the laminates and concrete were analyzed. Furthermore, bond–slip curves were compared with some other existing literature models. The results from the experiment showed that the ultimate load, peak bond stress, and slip increased with the increase in the BFRP and GFRP laminates length, width, and thickness. The values of peak shear stress and the corresponding maximum shear slip were significantly different because of the above-mentioned factors’ influence on them. The bond interface that contributes to the bearing of the shear load may grow to an extent and later shift from the loaded end when debonding progresses. Finally, the fractured surfaces of the failed FRP laminates were examined using scanning electron microscope (SEM), revealing that FRP rupture, debonding in concrete, and debonding in an adhesive–concrete interface were the main failure types. |
format | Online Article Text |
id | pubmed-7690919 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-76909192020-11-27 Effect of Different Bond Parameters on the Mechanical Properties of FRP and Concrete Interface Mensah, Comfort Wang, Zhenqing Bonsu, Alex Osei Liang, Wenyan Polymers (Basel) Article This paper presents double shear tests performed to investigate factors influencing the bond behavior between basalt fiber-reinforced polymer (BFRP), glass fiber-reinforced polymer (GFRP) laminate, and concrete blocks. In detail, thirty-six twin concrete blocks strengthened with the aforementioned FRP types were tested to evaluate the influence of FRP length, width, and thickness, and their bonding behavior. The 2D-DIC (digital image correlation) technique and several strain gauges bonded along the laminate were used to measure the strain distributions of the FRP-to-concrete interface. The failure mode, ultimate load, load–slip, strain distribution, and bond–slip relationships between the laminates and concrete were analyzed. Furthermore, bond–slip curves were compared with some other existing literature models. The results from the experiment showed that the ultimate load, peak bond stress, and slip increased with the increase in the BFRP and GFRP laminates length, width, and thickness. The values of peak shear stress and the corresponding maximum shear slip were significantly different because of the above-mentioned factors’ influence on them. The bond interface that contributes to the bearing of the shear load may grow to an extent and later shift from the loaded end when debonding progresses. Finally, the fractured surfaces of the failed FRP laminates were examined using scanning electron microscope (SEM), revealing that FRP rupture, debonding in concrete, and debonding in an adhesive–concrete interface were the main failure types. MDPI 2020-10-24 /pmc/articles/PMC7690919/ /pubmed/33114349 http://dx.doi.org/10.3390/polym12112466 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Mensah, Comfort Wang, Zhenqing Bonsu, Alex Osei Liang, Wenyan Effect of Different Bond Parameters on the Mechanical Properties of FRP and Concrete Interface |
title | Effect of Different Bond Parameters on the Mechanical Properties of FRP and Concrete Interface |
title_full | Effect of Different Bond Parameters on the Mechanical Properties of FRP and Concrete Interface |
title_fullStr | Effect of Different Bond Parameters on the Mechanical Properties of FRP and Concrete Interface |
title_full_unstemmed | Effect of Different Bond Parameters on the Mechanical Properties of FRP and Concrete Interface |
title_short | Effect of Different Bond Parameters on the Mechanical Properties of FRP and Concrete Interface |
title_sort | effect of different bond parameters on the mechanical properties of frp and concrete interface |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7690919/ https://www.ncbi.nlm.nih.gov/pubmed/33114349 http://dx.doi.org/10.3390/polym12112466 |
work_keys_str_mv | AT mensahcomfort effectofdifferentbondparametersonthemechanicalpropertiesoffrpandconcreteinterface AT wangzhenqing effectofdifferentbondparametersonthemechanicalpropertiesoffrpandconcreteinterface AT bonsualexosei effectofdifferentbondparametersonthemechanicalpropertiesoffrpandconcreteinterface AT liangwenyan effectofdifferentbondparametersonthemechanicalpropertiesoffrpandconcreteinterface |