Validity of Three-Dimensional Tortuous Pore Structure and Fouling of Hemoconcentration Capillary Membrane Using the Tortuous Pore Diffusion Model and Scanning Probe Microscopy

Hemoconcentration membranes used in cardiopulmonary bypass require a pore structure design with high pure water permeability, which does not allow excessive protein adsorption and useful protein loss. However, studies on hemoconcentration membranes have not been conducted yet. The purpose of this st...

Descripción completa

Detalles Bibliográficos
Autores principales: Fukuda, Makoto, Yoshimoto, Hiroki, Saomoto, Hitoshi, Sakai, Kiyotaka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7692505/
https://www.ncbi.nlm.nih.gov/pubmed/33138163
http://dx.doi.org/10.3390/membranes10110315
_version_ 1783614527434129408
author Fukuda, Makoto
Yoshimoto, Hiroki
Saomoto, Hitoshi
Sakai, Kiyotaka
author_facet Fukuda, Makoto
Yoshimoto, Hiroki
Saomoto, Hitoshi
Sakai, Kiyotaka
author_sort Fukuda, Makoto
collection PubMed
description Hemoconcentration membranes used in cardiopulmonary bypass require a pore structure design with high pure water permeability, which does not allow excessive protein adsorption and useful protein loss. However, studies on hemoconcentration membranes have not been conducted yet. The purpose of this study was to analyze three-dimensional pore structures and protein fouling before and after blood contact with capillary membranes using the tortuous pore diffusion model and a scanning probe microscope system. We examined two commercially available capillary membranes of similar polymer composition that are successfully used in hemoconcentration clinically. Assuming the conditions of actual use in cardiopulmonary bypass, bovine blood was perfused inside the lumens of these membranes. Pure water permeability before and after bovine blood perfusion was measured using dead-end filtration. The scanning probe microscopy system was used for analysis. High-resolution three-dimensional pore structures on the inner surface of the membranes were observed before blood contact. On the other hand, many pore structures after blood contact could not be observed due to protein fouling. The pore diameters calculated by the tortuous pore diffusion model and scanning probe microscopy were mostly similar and could be validated reciprocally. Achievable pure water permeabilities showed no difference, despite protein fouling on the pore inlets (membrane surface). In addition, low values of albumin sieving coefficient are attributable to protein fouling that occurs on the membrane surface. Therefore, it is essential to design the membrane structure that provides the appropriate control of fouling. The characteristics of the hemoconcentration membranes examined in this study are suitable for clinical use.
format Online
Article
Text
id pubmed-7692505
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76925052020-11-28 Validity of Three-Dimensional Tortuous Pore Structure and Fouling of Hemoconcentration Capillary Membrane Using the Tortuous Pore Diffusion Model and Scanning Probe Microscopy Fukuda, Makoto Yoshimoto, Hiroki Saomoto, Hitoshi Sakai, Kiyotaka Membranes (Basel) Article Hemoconcentration membranes used in cardiopulmonary bypass require a pore structure design with high pure water permeability, which does not allow excessive protein adsorption and useful protein loss. However, studies on hemoconcentration membranes have not been conducted yet. The purpose of this study was to analyze three-dimensional pore structures and protein fouling before and after blood contact with capillary membranes using the tortuous pore diffusion model and a scanning probe microscope system. We examined two commercially available capillary membranes of similar polymer composition that are successfully used in hemoconcentration clinically. Assuming the conditions of actual use in cardiopulmonary bypass, bovine blood was perfused inside the lumens of these membranes. Pure water permeability before and after bovine blood perfusion was measured using dead-end filtration. The scanning probe microscopy system was used for analysis. High-resolution three-dimensional pore structures on the inner surface of the membranes were observed before blood contact. On the other hand, many pore structures after blood contact could not be observed due to protein fouling. The pore diameters calculated by the tortuous pore diffusion model and scanning probe microscopy were mostly similar and could be validated reciprocally. Achievable pure water permeabilities showed no difference, despite protein fouling on the pore inlets (membrane surface). In addition, low values of albumin sieving coefficient are attributable to protein fouling that occurs on the membrane surface. Therefore, it is essential to design the membrane structure that provides the appropriate control of fouling. The characteristics of the hemoconcentration membranes examined in this study are suitable for clinical use. MDPI 2020-10-29 /pmc/articles/PMC7692505/ /pubmed/33138163 http://dx.doi.org/10.3390/membranes10110315 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Fukuda, Makoto
Yoshimoto, Hiroki
Saomoto, Hitoshi
Sakai, Kiyotaka
Validity of Three-Dimensional Tortuous Pore Structure and Fouling of Hemoconcentration Capillary Membrane Using the Tortuous Pore Diffusion Model and Scanning Probe Microscopy
title Validity of Three-Dimensional Tortuous Pore Structure and Fouling of Hemoconcentration Capillary Membrane Using the Tortuous Pore Diffusion Model and Scanning Probe Microscopy
title_full Validity of Three-Dimensional Tortuous Pore Structure and Fouling of Hemoconcentration Capillary Membrane Using the Tortuous Pore Diffusion Model and Scanning Probe Microscopy
title_fullStr Validity of Three-Dimensional Tortuous Pore Structure and Fouling of Hemoconcentration Capillary Membrane Using the Tortuous Pore Diffusion Model and Scanning Probe Microscopy
title_full_unstemmed Validity of Three-Dimensional Tortuous Pore Structure and Fouling of Hemoconcentration Capillary Membrane Using the Tortuous Pore Diffusion Model and Scanning Probe Microscopy
title_short Validity of Three-Dimensional Tortuous Pore Structure and Fouling of Hemoconcentration Capillary Membrane Using the Tortuous Pore Diffusion Model and Scanning Probe Microscopy
title_sort validity of three-dimensional tortuous pore structure and fouling of hemoconcentration capillary membrane using the tortuous pore diffusion model and scanning probe microscopy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7692505/
https://www.ncbi.nlm.nih.gov/pubmed/33138163
http://dx.doi.org/10.3390/membranes10110315
work_keys_str_mv AT fukudamakoto validityofthreedimensionaltortuousporestructureandfoulingofhemoconcentrationcapillarymembraneusingthetortuousporediffusionmodelandscanningprobemicroscopy
AT yoshimotohiroki validityofthreedimensionaltortuousporestructureandfoulingofhemoconcentrationcapillarymembraneusingthetortuousporediffusionmodelandscanningprobemicroscopy
AT saomotohitoshi validityofthreedimensionaltortuousporestructureandfoulingofhemoconcentrationcapillarymembraneusingthetortuousporediffusionmodelandscanningprobemicroscopy
AT sakaikiyotaka validityofthreedimensionaltortuousporestructureandfoulingofhemoconcentrationcapillarymembraneusingthetortuousporediffusionmodelandscanningprobemicroscopy