Cargando…

Mold-Face Heating Mechanism, Overflow-Well Design, and Their Effect on Surface Weldline and Tensile Strength of Long-Glass-Fiber-Reinforced Polypropylene Injection Molding

Long-fiber polymers offer the advantage of a lower production cost because specific tool designs are required for conventional injection molding equipment to produce long-fiber polymer parts. The use of long fibers allows relatively high fiber aspect ratios to be obtained, thereby enhancing composit...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Po-Wei, Peng, Hsin-Shu, Choong, Wei-Huang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7692597/
https://www.ncbi.nlm.nih.gov/pubmed/33113821
http://dx.doi.org/10.3390/polym12112474
_version_ 1783614549133361152
author Huang, Po-Wei
Peng, Hsin-Shu
Choong, Wei-Huang
author_facet Huang, Po-Wei
Peng, Hsin-Shu
Choong, Wei-Huang
author_sort Huang, Po-Wei
collection PubMed
description Long-fiber polymers offer the advantage of a lower production cost because specific tool designs are required for conventional injection molding equipment to produce long-fiber polymer parts. The use of long fibers allows relatively high fiber aspect ratios to be obtained, thereby enhancing composite stiffness, strength, creep endurance, and fatigue endurance. However, the multigate design of the injection-molded part can result in weldline formation during the molding process, which reduces the structural strength of the molded part. Therefore, in this study, the surface quality, fiber compatibility, and structural strength of long-glass-fiber-reinforced polypropylene (PP/LGF) injection-molded samples were compared in the use versus nonuse of a mold-cavity overflow-well area and the mold-face infrared heating method. The experimental results indicate that the mold-cavity overflow-well area more greatly improved the surface roughness of the PP/LGF molded samples. Moreover, the infrared heating of the mold-face decreased the weldline depth of the samples. Optical-microscopy images and mold-cavity pressure distributions indicated that the weldline tensile strength and the interface compatibility between fibers and melts at the weldline region during the molding stage were higher in the use than in the nonuse of the mold-cavity overflow-well and mold-face infrared heating method.
format Online
Article
Text
id pubmed-7692597
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76925972020-11-28 Mold-Face Heating Mechanism, Overflow-Well Design, and Their Effect on Surface Weldline and Tensile Strength of Long-Glass-Fiber-Reinforced Polypropylene Injection Molding Huang, Po-Wei Peng, Hsin-Shu Choong, Wei-Huang Polymers (Basel) Article Long-fiber polymers offer the advantage of a lower production cost because specific tool designs are required for conventional injection molding equipment to produce long-fiber polymer parts. The use of long fibers allows relatively high fiber aspect ratios to be obtained, thereby enhancing composite stiffness, strength, creep endurance, and fatigue endurance. However, the multigate design of the injection-molded part can result in weldline formation during the molding process, which reduces the structural strength of the molded part. Therefore, in this study, the surface quality, fiber compatibility, and structural strength of long-glass-fiber-reinforced polypropylene (PP/LGF) injection-molded samples were compared in the use versus nonuse of a mold-cavity overflow-well area and the mold-face infrared heating method. The experimental results indicate that the mold-cavity overflow-well area more greatly improved the surface roughness of the PP/LGF molded samples. Moreover, the infrared heating of the mold-face decreased the weldline depth of the samples. Optical-microscopy images and mold-cavity pressure distributions indicated that the weldline tensile strength and the interface compatibility between fibers and melts at the weldline region during the molding stage were higher in the use than in the nonuse of the mold-cavity overflow-well and mold-face infrared heating method. MDPI 2020-10-25 /pmc/articles/PMC7692597/ /pubmed/33113821 http://dx.doi.org/10.3390/polym12112474 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Huang, Po-Wei
Peng, Hsin-Shu
Choong, Wei-Huang
Mold-Face Heating Mechanism, Overflow-Well Design, and Their Effect on Surface Weldline and Tensile Strength of Long-Glass-Fiber-Reinforced Polypropylene Injection Molding
title Mold-Face Heating Mechanism, Overflow-Well Design, and Their Effect on Surface Weldline and Tensile Strength of Long-Glass-Fiber-Reinforced Polypropylene Injection Molding
title_full Mold-Face Heating Mechanism, Overflow-Well Design, and Their Effect on Surface Weldline and Tensile Strength of Long-Glass-Fiber-Reinforced Polypropylene Injection Molding
title_fullStr Mold-Face Heating Mechanism, Overflow-Well Design, and Their Effect on Surface Weldline and Tensile Strength of Long-Glass-Fiber-Reinforced Polypropylene Injection Molding
title_full_unstemmed Mold-Face Heating Mechanism, Overflow-Well Design, and Their Effect on Surface Weldline and Tensile Strength of Long-Glass-Fiber-Reinforced Polypropylene Injection Molding
title_short Mold-Face Heating Mechanism, Overflow-Well Design, and Their Effect on Surface Weldline and Tensile Strength of Long-Glass-Fiber-Reinforced Polypropylene Injection Molding
title_sort mold-face heating mechanism, overflow-well design, and their effect on surface weldline and tensile strength of long-glass-fiber-reinforced polypropylene injection molding
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7692597/
https://www.ncbi.nlm.nih.gov/pubmed/33113821
http://dx.doi.org/10.3390/polym12112474
work_keys_str_mv AT huangpowei moldfaceheatingmechanismoverflowwelldesignandtheireffectonsurfaceweldlineandtensilestrengthoflongglassfiberreinforcedpolypropyleneinjectionmolding
AT penghsinshu moldfaceheatingmechanismoverflowwelldesignandtheireffectonsurfaceweldlineandtensilestrengthoflongglassfiberreinforcedpolypropyleneinjectionmolding
AT choongweihuang moldfaceheatingmechanismoverflowwelldesignandtheireffectonsurfaceweldlineandtensilestrengthoflongglassfiberreinforcedpolypropyleneinjectionmolding