Cargando…

Reference values for 2‐dimensional and M‐mode echocardiography in Friesian and Warmblood horses

BACKGROUND: Echocardiographic reference intervals for Friesian horses are poorly described. OBJECTIVES: To obtain reference intervals for echocardiographic measurements in Friesians and compare these with Warmbloods. ANIMALS: One hundred healthy adult Friesians and 100 healthy adult Warmblood horses...

Descripción completa

Detalles Bibliográficos
Autores principales: Vernemmen, Ingrid, Vera, Lisse, Van Steenkiste, Glenn, van Loon, Gunther, Decloedt, Annelies
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7694853/
https://www.ncbi.nlm.nih.gov/pubmed/33098342
http://dx.doi.org/10.1111/jvim.15938
_version_ 1783615070925750272
author Vernemmen, Ingrid
Vera, Lisse
Van Steenkiste, Glenn
van Loon, Gunther
Decloedt, Annelies
author_facet Vernemmen, Ingrid
Vera, Lisse
Van Steenkiste, Glenn
van Loon, Gunther
Decloedt, Annelies
author_sort Vernemmen, Ingrid
collection PubMed
description BACKGROUND: Echocardiographic reference intervals for Friesian horses are poorly described. OBJECTIVES: To obtain reference intervals for echocardiographic measurements in Friesians and compare these with Warmbloods. ANIMALS: One hundred healthy adult Friesians and 100 healthy adult Warmblood horses. METHODS: Cross‐sectional study. Two‐dimensional and M‐mode echocardiographic images were obtained. Echocardiographic measurements, including size, area, and volumetric measurements of left atrium, left and right ventricle, aorta, and pulmonary artery, were performed. Measurements were compared between the 2 breeds using an independent samples t test with Bonferroni correction for multiple comparisons. RESULTS: Reference ranges for standard echocardiographic measurements in Friesians were obtained. Several left ventricular measurements were significantly smaller in Friesians compared to Warmbloods, such as the left ventricular end‐diastolic volume using the 4‐chamber modified Simpsons' method (99.85% confidence interval for the difference [CI] = −245 to −63). Also the right ventricular end‐diastolic and peak‐systolic internal diameter were smaller in Friesians (99.85% CI = −1.33 to −0.6 and 99.85% CI = −1.54 to −0.76, respectively). Fractional shortening (99.85% CI = 0.61‐6) and ejection fraction (99.85% CI = 0.21‐4.6) were significantly larger. No structural effects of systemic hypertension, such as concentric hypertrophy, were detected. CONCLUSIONS AND CLINICAL IMPORTANCE: Our study provides reference intervals for echocardiographic measurements in Friesians useful in a clinical setting. In general, the left ventricular dimensions in Friesians were significantly smaller compared to Warmbloods, emphasizing the need for breed‐specific reference intervals.
format Online
Article
Text
id pubmed-7694853
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-76948532020-12-07 Reference values for 2‐dimensional and M‐mode echocardiography in Friesian and Warmblood horses Vernemmen, Ingrid Vera, Lisse Van Steenkiste, Glenn van Loon, Gunther Decloedt, Annelies J Vet Intern Med EQUINE BACKGROUND: Echocardiographic reference intervals for Friesian horses are poorly described. OBJECTIVES: To obtain reference intervals for echocardiographic measurements in Friesians and compare these with Warmbloods. ANIMALS: One hundred healthy adult Friesians and 100 healthy adult Warmblood horses. METHODS: Cross‐sectional study. Two‐dimensional and M‐mode echocardiographic images were obtained. Echocardiographic measurements, including size, area, and volumetric measurements of left atrium, left and right ventricle, aorta, and pulmonary artery, were performed. Measurements were compared between the 2 breeds using an independent samples t test with Bonferroni correction for multiple comparisons. RESULTS: Reference ranges for standard echocardiographic measurements in Friesians were obtained. Several left ventricular measurements were significantly smaller in Friesians compared to Warmbloods, such as the left ventricular end‐diastolic volume using the 4‐chamber modified Simpsons' method (99.85% confidence interval for the difference [CI] = −245 to −63). Also the right ventricular end‐diastolic and peak‐systolic internal diameter were smaller in Friesians (99.85% CI = −1.33 to −0.6 and 99.85% CI = −1.54 to −0.76, respectively). Fractional shortening (99.85% CI = 0.61‐6) and ejection fraction (99.85% CI = 0.21‐4.6) were significantly larger. No structural effects of systemic hypertension, such as concentric hypertrophy, were detected. CONCLUSIONS AND CLINICAL IMPORTANCE: Our study provides reference intervals for echocardiographic measurements in Friesians useful in a clinical setting. In general, the left ventricular dimensions in Friesians were significantly smaller compared to Warmbloods, emphasizing the need for breed‐specific reference intervals. John Wiley & Sons, Inc. 2020-10-24 2020 /pmc/articles/PMC7694853/ /pubmed/33098342 http://dx.doi.org/10.1111/jvim.15938 Text en © 2020 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals LLC on behalf of American College of Veterinary Internal Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle EQUINE
Vernemmen, Ingrid
Vera, Lisse
Van Steenkiste, Glenn
van Loon, Gunther
Decloedt, Annelies
Reference values for 2‐dimensional and M‐mode echocardiography in Friesian and Warmblood horses
title Reference values for 2‐dimensional and M‐mode echocardiography in Friesian and Warmblood horses
title_full Reference values for 2‐dimensional and M‐mode echocardiography in Friesian and Warmblood horses
title_fullStr Reference values for 2‐dimensional and M‐mode echocardiography in Friesian and Warmblood horses
title_full_unstemmed Reference values for 2‐dimensional and M‐mode echocardiography in Friesian and Warmblood horses
title_short Reference values for 2‐dimensional and M‐mode echocardiography in Friesian and Warmblood horses
title_sort reference values for 2‐dimensional and m‐mode echocardiography in friesian and warmblood horses
topic EQUINE
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7694853/
https://www.ncbi.nlm.nih.gov/pubmed/33098342
http://dx.doi.org/10.1111/jvim.15938
work_keys_str_mv AT vernemmeningrid referencevaluesfor2dimensionalandmmodeechocardiographyinfriesianandwarmbloodhorses
AT veralisse referencevaluesfor2dimensionalandmmodeechocardiographyinfriesianandwarmbloodhorses
AT vansteenkisteglenn referencevaluesfor2dimensionalandmmodeechocardiographyinfriesianandwarmbloodhorses
AT vanloongunther referencevaluesfor2dimensionalandmmodeechocardiographyinfriesianandwarmbloodhorses
AT decloedtannelies referencevaluesfor2dimensionalandmmodeechocardiographyinfriesianandwarmbloodhorses