Comparison of Contrast Enhanced Magnetic Resonance Angiography to Computed Tomography in Detecting Pulmonary Arteriovenous Malformations

Background: Computed tomography (CT) is considered the imaging modality of choice to diagnose pulmonary arteriovenous malformations PAVMs. The drawback of this technique is that it requires ionizing radiation. Magnetic resonance (MR) imaging does not have the limitation, but little is known about th...

Descripción completa

Detalles Bibliográficos
Autores principales: van den Heuvel, Daniel A.F., Post, Marco C., Koot, Ward, Kelder, Johannes C., van Es, Hendrik W., Snijder, Repke J., Vos, Jan-Albert, Mager, Johannes J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7696184/
https://www.ncbi.nlm.nih.gov/pubmed/33202566
http://dx.doi.org/10.3390/jcm9113662
_version_ 1783615351616962560
author van den Heuvel, Daniel A.F.
Post, Marco C.
Koot, Ward
Kelder, Johannes C.
van Es, Hendrik W.
Snijder, Repke J.
Vos, Jan-Albert
Mager, Johannes J.
author_facet van den Heuvel, Daniel A.F.
Post, Marco C.
Koot, Ward
Kelder, Johannes C.
van Es, Hendrik W.
Snijder, Repke J.
Vos, Jan-Albert
Mager, Johannes J.
author_sort van den Heuvel, Daniel A.F.
collection PubMed
description Background: Computed tomography (CT) is considered the imaging modality of choice to diagnose pulmonary arteriovenous malformations PAVMs. The drawback of this technique is that it requires ionizing radiation. Magnetic resonance (MR) imaging does not have the limitation, but little is known about the performance of MR compared to CT for the detection of PAVMs. The aim of this study is to investigate the sensitivity of contrast-enhanced MR angiography (CE-MRA) in the detection of PAVMs with feeding artery diameters (FAD) > 2 mm. Methods: Patients with a grade 2 or 3 shunt on screening transthoracic contrast echocardiography (TTCE) were asked to participate. Included patients underwent chest CT and CE-MRA. CT was considered the reference standard. CT and CE-MRA scans were anonymized and assessed for the presence of PAVMs with FAD > 2 mm by one and two readers respectively. Data analysis was performed on per patient and per PAVM basis. Results: Fifty-three patients were included. 105 PAVMs were detected on CT, 45 with a FAD ≥ 2 mm. In per patient analysis, sensitivity and specificity of CE-MRA were 92% and 97% respectively for reader 1 and 92% and 62% for reader 2. Negative and positive predictive value (NPV/PPV) were 93% and 96% for R1 and 90% and 67% for R2. In per PAVM analysis, sensitivity, specificity, NPV and PPV were 96%, 99%, 100% and 86% for R1 and 93%, 96%, 100% and 56% for R2, respectively. Conclusions: CE-MRA has excellent sensitivity and NPV for detection of PAVMs with FAD ≥ 2 mm and can therefore be used to detect these PAVMs. We are hopeful that future advancements in CE-MRA technology will reduce false positive rates and allow for more broad use of CE-MRA in PAVM diagnosis and management.
format Online
Article
Text
id pubmed-7696184
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76961842020-11-29 Comparison of Contrast Enhanced Magnetic Resonance Angiography to Computed Tomography in Detecting Pulmonary Arteriovenous Malformations van den Heuvel, Daniel A.F. Post, Marco C. Koot, Ward Kelder, Johannes C. van Es, Hendrik W. Snijder, Repke J. Vos, Jan-Albert Mager, Johannes J. J Clin Med Article Background: Computed tomography (CT) is considered the imaging modality of choice to diagnose pulmonary arteriovenous malformations PAVMs. The drawback of this technique is that it requires ionizing radiation. Magnetic resonance (MR) imaging does not have the limitation, but little is known about the performance of MR compared to CT for the detection of PAVMs. The aim of this study is to investigate the sensitivity of contrast-enhanced MR angiography (CE-MRA) in the detection of PAVMs with feeding artery diameters (FAD) > 2 mm. Methods: Patients with a grade 2 or 3 shunt on screening transthoracic contrast echocardiography (TTCE) were asked to participate. Included patients underwent chest CT and CE-MRA. CT was considered the reference standard. CT and CE-MRA scans were anonymized and assessed for the presence of PAVMs with FAD > 2 mm by one and two readers respectively. Data analysis was performed on per patient and per PAVM basis. Results: Fifty-three patients were included. 105 PAVMs were detected on CT, 45 with a FAD ≥ 2 mm. In per patient analysis, sensitivity and specificity of CE-MRA were 92% and 97% respectively for reader 1 and 92% and 62% for reader 2. Negative and positive predictive value (NPV/PPV) were 93% and 96% for R1 and 90% and 67% for R2. In per PAVM analysis, sensitivity, specificity, NPV and PPV were 96%, 99%, 100% and 86% for R1 and 93%, 96%, 100% and 56% for R2, respectively. Conclusions: CE-MRA has excellent sensitivity and NPV for detection of PAVMs with FAD ≥ 2 mm and can therefore be used to detect these PAVMs. We are hopeful that future advancements in CE-MRA technology will reduce false positive rates and allow for more broad use of CE-MRA in PAVM diagnosis and management. MDPI 2020-11-14 /pmc/articles/PMC7696184/ /pubmed/33202566 http://dx.doi.org/10.3390/jcm9113662 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
van den Heuvel, Daniel A.F.
Post, Marco C.
Koot, Ward
Kelder, Johannes C.
van Es, Hendrik W.
Snijder, Repke J.
Vos, Jan-Albert
Mager, Johannes J.
Comparison of Contrast Enhanced Magnetic Resonance Angiography to Computed Tomography in Detecting Pulmonary Arteriovenous Malformations
title Comparison of Contrast Enhanced Magnetic Resonance Angiography to Computed Tomography in Detecting Pulmonary Arteriovenous Malformations
title_full Comparison of Contrast Enhanced Magnetic Resonance Angiography to Computed Tomography in Detecting Pulmonary Arteriovenous Malformations
title_fullStr Comparison of Contrast Enhanced Magnetic Resonance Angiography to Computed Tomography in Detecting Pulmonary Arteriovenous Malformations
title_full_unstemmed Comparison of Contrast Enhanced Magnetic Resonance Angiography to Computed Tomography in Detecting Pulmonary Arteriovenous Malformations
title_short Comparison of Contrast Enhanced Magnetic Resonance Angiography to Computed Tomography in Detecting Pulmonary Arteriovenous Malformations
title_sort comparison of contrast enhanced magnetic resonance angiography to computed tomography in detecting pulmonary arteriovenous malformations
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7696184/
https://www.ncbi.nlm.nih.gov/pubmed/33202566
http://dx.doi.org/10.3390/jcm9113662
work_keys_str_mv AT vandenheuveldanielaf comparisonofcontrastenhancedmagneticresonanceangiographytocomputedtomographyindetectingpulmonaryarteriovenousmalformations
AT postmarcoc comparisonofcontrastenhancedmagneticresonanceangiographytocomputedtomographyindetectingpulmonaryarteriovenousmalformations
AT kootward comparisonofcontrastenhancedmagneticresonanceangiographytocomputedtomographyindetectingpulmonaryarteriovenousmalformations
AT kelderjohannesc comparisonofcontrastenhancedmagneticresonanceangiographytocomputedtomographyindetectingpulmonaryarteriovenousmalformations
AT vaneshendrikw comparisonofcontrastenhancedmagneticresonanceangiographytocomputedtomographyindetectingpulmonaryarteriovenousmalformations
AT snijderrepkej comparisonofcontrastenhancedmagneticresonanceangiographytocomputedtomographyindetectingpulmonaryarteriovenousmalformations
AT vosjanalbert comparisonofcontrastenhancedmagneticresonanceangiographytocomputedtomographyindetectingpulmonaryarteriovenousmalformations
AT magerjohannesj comparisonofcontrastenhancedmagneticresonanceangiographytocomputedtomographyindetectingpulmonaryarteriovenousmalformations