High-Sensitivity Cuboid Interferometric Fiber-Optic Hydrophone Based on Planar Rectangular Film Sensing

Interferometric fiber-optic hydrophones are an important means in the field of underwater acoustic detection. The design of the hydrophone sensor head is the key technology related to its detection sensitivity. In this paper, a high-sensitivity cuboid interferometric fiber-optic hydrophone based on...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Wenrui, Pei, Yeye, Ye, Lingyun, Song, Kaichen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7696286/
https://www.ncbi.nlm.nih.gov/pubmed/33182757
http://dx.doi.org/10.3390/s20226422
_version_ 1783615375593701376
author Wang, Wenrui
Pei, Yeye
Ye, Lingyun
Song, Kaichen
author_facet Wang, Wenrui
Pei, Yeye
Ye, Lingyun
Song, Kaichen
author_sort Wang, Wenrui
collection PubMed
description Interferometric fiber-optic hydrophones are an important means in the field of underwater acoustic detection. The design of the hydrophone sensor head is the key technology related to its detection sensitivity. In this paper, a high-sensitivity cuboid interferometric fiber-optic hydrophone based on planar rectangular film sensing is proposed, and the sensitivity of the sensor is compared with that of the widely used air-backed mandrel hydrophone under the same conditions. The acoustic characteristic models of the two types of sensors were established by theoretical calculation and simulation analysis to obtain the theoretical pressure sensitivity. Some experiments were performed to examine the theory and design. According to the experiment results, the mean phase sensitivity of the mandrel type was −112.85 dB re 1 rad/μPa in the operating frequency range of 10–300 Hz, and that of the cuboid type was −84.50 dB re 1 rad/μPa. The latter was 28.35 dB higher than the former was. These results are useful for improving hydrophone sensitivity.
format Online
Article
Text
id pubmed-7696286
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76962862020-11-29 High-Sensitivity Cuboid Interferometric Fiber-Optic Hydrophone Based on Planar Rectangular Film Sensing Wang, Wenrui Pei, Yeye Ye, Lingyun Song, Kaichen Sensors (Basel) Letter Interferometric fiber-optic hydrophones are an important means in the field of underwater acoustic detection. The design of the hydrophone sensor head is the key technology related to its detection sensitivity. In this paper, a high-sensitivity cuboid interferometric fiber-optic hydrophone based on planar rectangular film sensing is proposed, and the sensitivity of the sensor is compared with that of the widely used air-backed mandrel hydrophone under the same conditions. The acoustic characteristic models of the two types of sensors were established by theoretical calculation and simulation analysis to obtain the theoretical pressure sensitivity. Some experiments were performed to examine the theory and design. According to the experiment results, the mean phase sensitivity of the mandrel type was −112.85 dB re 1 rad/μPa in the operating frequency range of 10–300 Hz, and that of the cuboid type was −84.50 dB re 1 rad/μPa. The latter was 28.35 dB higher than the former was. These results are useful for improving hydrophone sensitivity. MDPI 2020-11-10 /pmc/articles/PMC7696286/ /pubmed/33182757 http://dx.doi.org/10.3390/s20226422 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Letter
Wang, Wenrui
Pei, Yeye
Ye, Lingyun
Song, Kaichen
High-Sensitivity Cuboid Interferometric Fiber-Optic Hydrophone Based on Planar Rectangular Film Sensing
title High-Sensitivity Cuboid Interferometric Fiber-Optic Hydrophone Based on Planar Rectangular Film Sensing
title_full High-Sensitivity Cuboid Interferometric Fiber-Optic Hydrophone Based on Planar Rectangular Film Sensing
title_fullStr High-Sensitivity Cuboid Interferometric Fiber-Optic Hydrophone Based on Planar Rectangular Film Sensing
title_full_unstemmed High-Sensitivity Cuboid Interferometric Fiber-Optic Hydrophone Based on Planar Rectangular Film Sensing
title_short High-Sensitivity Cuboid Interferometric Fiber-Optic Hydrophone Based on Planar Rectangular Film Sensing
title_sort high-sensitivity cuboid interferometric fiber-optic hydrophone based on planar rectangular film sensing
topic Letter
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7696286/
https://www.ncbi.nlm.nih.gov/pubmed/33182757
http://dx.doi.org/10.3390/s20226422
work_keys_str_mv AT wangwenrui highsensitivitycuboidinterferometricfiberoptichydrophonebasedonplanarrectangularfilmsensing
AT peiyeye highsensitivitycuboidinterferometricfiberoptichydrophonebasedonplanarrectangularfilmsensing
AT yelingyun highsensitivitycuboidinterferometricfiberoptichydrophonebasedonplanarrectangularfilmsensing
AT songkaichen highsensitivitycuboidinterferometricfiberoptichydrophonebasedonplanarrectangularfilmsensing