Cargando…
Desorption from Hot Scandate Cathodes: Effects on Vacuum Device Interior Surfaces after Long-Term Operation
Scandate cathodes have exhibited superior emission properties compared to current state-of-the-art “M-type” thermionic cathodes. However, their integration into vacuum devices is limited in part by a lack of knowledge regarding their functional lifespan and behavior during operation. Here, we consid...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7696668/ https://www.ncbi.nlm.nih.gov/pubmed/33207569 http://dx.doi.org/10.3390/ma13225149 |
_version_ | 1783615456513359872 |
---|---|
author | Seif, Mujan N. Balk, T. John Beck, Matthew J. |
author_facet | Seif, Mujan N. Balk, T. John Beck, Matthew J. |
author_sort | Seif, Mujan N. |
collection | PubMed |
description | Scandate cathodes have exhibited superior emission properties compared to current state-of-the-art “M-type” thermionic cathodes. However, their integration into vacuum devices is limited in part by a lack of knowledge regarding their functional lifespan and behavior during operation. Here, we consider thermal desorption from scandate cathodes by examining the distribution of material deposited on interior surfaces of a sealed vacuum device after ~26,000 h of cathode operation. XPS, EDS, and TEM analyses indicate that on the order of 1 wt.% of the initial impregnate is desorbed during a cathode’s lifetime, Ca does not desorb uniformly with time, and little to no Sc desorbs from the cathode surfaces (or does so at an undetectable rate). Findings from this first-ever study of a scandate cathode after extremely long-time operation yield insight into the utility of scandate cathodes as components in vacuum devices and suggest possible effects on device performance due to deposition of desorption products on interior device surfaces. |
format | Online Article Text |
id | pubmed-7696668 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-76966682020-11-29 Desorption from Hot Scandate Cathodes: Effects on Vacuum Device Interior Surfaces after Long-Term Operation Seif, Mujan N. Balk, T. John Beck, Matthew J. Materials (Basel) Article Scandate cathodes have exhibited superior emission properties compared to current state-of-the-art “M-type” thermionic cathodes. However, their integration into vacuum devices is limited in part by a lack of knowledge regarding their functional lifespan and behavior during operation. Here, we consider thermal desorption from scandate cathodes by examining the distribution of material deposited on interior surfaces of a sealed vacuum device after ~26,000 h of cathode operation. XPS, EDS, and TEM analyses indicate that on the order of 1 wt.% of the initial impregnate is desorbed during a cathode’s lifetime, Ca does not desorb uniformly with time, and little to no Sc desorbs from the cathode surfaces (or does so at an undetectable rate). Findings from this first-ever study of a scandate cathode after extremely long-time operation yield insight into the utility of scandate cathodes as components in vacuum devices and suggest possible effects on device performance due to deposition of desorption products on interior device surfaces. MDPI 2020-11-16 /pmc/articles/PMC7696668/ /pubmed/33207569 http://dx.doi.org/10.3390/ma13225149 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Seif, Mujan N. Balk, T. John Beck, Matthew J. Desorption from Hot Scandate Cathodes: Effects on Vacuum Device Interior Surfaces after Long-Term Operation |
title | Desorption from Hot Scandate Cathodes: Effects on Vacuum Device Interior Surfaces after Long-Term Operation |
title_full | Desorption from Hot Scandate Cathodes: Effects on Vacuum Device Interior Surfaces after Long-Term Operation |
title_fullStr | Desorption from Hot Scandate Cathodes: Effects on Vacuum Device Interior Surfaces after Long-Term Operation |
title_full_unstemmed | Desorption from Hot Scandate Cathodes: Effects on Vacuum Device Interior Surfaces after Long-Term Operation |
title_short | Desorption from Hot Scandate Cathodes: Effects on Vacuum Device Interior Surfaces after Long-Term Operation |
title_sort | desorption from hot scandate cathodes: effects on vacuum device interior surfaces after long-term operation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7696668/ https://www.ncbi.nlm.nih.gov/pubmed/33207569 http://dx.doi.org/10.3390/ma13225149 |
work_keys_str_mv | AT seifmujann desorptionfromhotscandatecathodeseffectsonvacuumdeviceinteriorsurfacesafterlongtermoperation AT balktjohn desorptionfromhotscandatecathodeseffectsonvacuumdeviceinteriorsurfacesafterlongtermoperation AT beckmatthewj desorptionfromhotscandatecathodeseffectsonvacuumdeviceinteriorsurfacesafterlongtermoperation |