Cargando…

Coenzyme Q10 Efficacy Test for Human Skin Equivalents Using a Pumpless Skin-On-A-Chip System

A human skin equivalent (HSE) composed of the epidermis and dermis is cultured using a pumpless skin-on-a-chip system to supply cultures the desired flow rate using gravity flow without a pump or an external tube connection. Coenzyme Q10 efficacy is tested by adjusting its concentration, as it is kn...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Jisue, Kim, Kyunghee, Sung, Gun Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7697574/
https://www.ncbi.nlm.nih.gov/pubmed/33187177
http://dx.doi.org/10.3390/ijms21228475
_version_ 1783615627693391872
author Kim, Jisue
Kim, Kyunghee
Sung, Gun Yong
author_facet Kim, Jisue
Kim, Kyunghee
Sung, Gun Yong
author_sort Kim, Jisue
collection PubMed
description A human skin equivalent (HSE) composed of the epidermis and dermis is cultured using a pumpless skin-on-a-chip system to supply cultures the desired flow rate using gravity flow without a pump or an external tube connection. Coenzyme Q10 efficacy is tested by adjusting its concentration, as it is known to have anti-aging and antioxidant effects in culture solutions. The relationship between the contraction rate of a full-thickness human skin equivalent and secreted transforming growth factor (TGF) β-1 is analyzed via enzyme-linked immunosorbent assay (ELISA). Following hematoxylin and eosin (H&E) staining, an image of the skin equivalent is analyzed to measure the epidermal layer’s thickness. The cell density and differentiation of the dermis layer are investigated. Gene and protein expression in the dermal and epidermal layers are quantitatively analyzed using quantitative real time polymerase chain reaction (qPCR) and immunohistochemical staining. As the coenzyme Q10 treatment concentration increased, the number of cells per unit area and the thickness of the epidermal layer increased, the expression level of filaggrin increased, and the contraction rate of full-thickness HSE was proportional to the amount of TGF β-1 secreted.
format Online
Article
Text
id pubmed-7697574
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76975742020-11-29 Coenzyme Q10 Efficacy Test for Human Skin Equivalents Using a Pumpless Skin-On-A-Chip System Kim, Jisue Kim, Kyunghee Sung, Gun Yong Int J Mol Sci Article A human skin equivalent (HSE) composed of the epidermis and dermis is cultured using a pumpless skin-on-a-chip system to supply cultures the desired flow rate using gravity flow without a pump or an external tube connection. Coenzyme Q10 efficacy is tested by adjusting its concentration, as it is known to have anti-aging and antioxidant effects in culture solutions. The relationship between the contraction rate of a full-thickness human skin equivalent and secreted transforming growth factor (TGF) β-1 is analyzed via enzyme-linked immunosorbent assay (ELISA). Following hematoxylin and eosin (H&E) staining, an image of the skin equivalent is analyzed to measure the epidermal layer’s thickness. The cell density and differentiation of the dermis layer are investigated. Gene and protein expression in the dermal and epidermal layers are quantitatively analyzed using quantitative real time polymerase chain reaction (qPCR) and immunohistochemical staining. As the coenzyme Q10 treatment concentration increased, the number of cells per unit area and the thickness of the epidermal layer increased, the expression level of filaggrin increased, and the contraction rate of full-thickness HSE was proportional to the amount of TGF β-1 secreted. MDPI 2020-11-11 /pmc/articles/PMC7697574/ /pubmed/33187177 http://dx.doi.org/10.3390/ijms21228475 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kim, Jisue
Kim, Kyunghee
Sung, Gun Yong
Coenzyme Q10 Efficacy Test for Human Skin Equivalents Using a Pumpless Skin-On-A-Chip System
title Coenzyme Q10 Efficacy Test for Human Skin Equivalents Using a Pumpless Skin-On-A-Chip System
title_full Coenzyme Q10 Efficacy Test for Human Skin Equivalents Using a Pumpless Skin-On-A-Chip System
title_fullStr Coenzyme Q10 Efficacy Test for Human Skin Equivalents Using a Pumpless Skin-On-A-Chip System
title_full_unstemmed Coenzyme Q10 Efficacy Test for Human Skin Equivalents Using a Pumpless Skin-On-A-Chip System
title_short Coenzyme Q10 Efficacy Test for Human Skin Equivalents Using a Pumpless Skin-On-A-Chip System
title_sort coenzyme q10 efficacy test for human skin equivalents using a pumpless skin-on-a-chip system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7697574/
https://www.ncbi.nlm.nih.gov/pubmed/33187177
http://dx.doi.org/10.3390/ijms21228475
work_keys_str_mv AT kimjisue coenzymeq10efficacytestforhumanskinequivalentsusingapumplessskinonachipsystem
AT kimkyunghee coenzymeq10efficacytestforhumanskinequivalentsusingapumplessskinonachipsystem
AT sunggunyong coenzymeq10efficacytestforhumanskinequivalentsusingapumplessskinonachipsystem