Performance Parameters of Inductively Coupled Plasma Optical Emission Spectrometry and Graphite Furnace Atomic Absorption Spectrometry Techniques for Pd and Pt Determination in Automotive Catalysts
Palladium (Pd) and platinum (Pt) are extensively used as catalysts in the petrochemical and automotive industries, and due to high demand for them on the market, their recycling from spent supported catalysts is clearly needed. To assess the content of Pd and Pt in catalysts in order to establish th...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7697727/ https://www.ncbi.nlm.nih.gov/pubmed/33202565 http://dx.doi.org/10.3390/ma13225136 |
_version_ | 1783615664478486528 |
---|---|
author | Senila, Marin Cadar, Oana Senila, Lacrimioara Böringer, Sarah Seaudeau-Pirouley, Karine Ruiu, Andrea Lacroix-Desmazes, Patrick |
author_facet | Senila, Marin Cadar, Oana Senila, Lacrimioara Böringer, Sarah Seaudeau-Pirouley, Karine Ruiu, Andrea Lacroix-Desmazes, Patrick |
author_sort | Senila, Marin |
collection | PubMed |
description | Palladium (Pd) and platinum (Pt) are extensively used as catalysts in the petrochemical and automotive industries, and due to high demand for them on the market, their recycling from spent supported catalysts is clearly needed. To assess the content of Pd and Pt in catalysts in order to establish their commercial value or to evaluate the recovery efficiency of technologies used for recycling, reliable analytical methods for determination of these elements are required. Spectrometric methods, such as inductively coupled plasma optical emission spectrometry (ICP-OES) and graphite furnace atomic absorption spectrometry (GFAAS) are powerful tools that can be employed for the determination of Pd and Pt in various sample matrices. However, these methods allow only the injection of liquid samples. In this regard, the digestion of solid sample by microwave-assisted acid extraction procedures at high pressures and temperatures is often used. In this study, a microwave acid digestion method was optimized for the extraction of Pd and Pt from spent catalysts, using a four-step program, at a maximum 200 °C. The resulting solutions were analyzed using ICP-OES, at two different wavelengths for each metal (Pd at 340.458 and 363.470 nm, and Pt at 265.945 and 214.423 nm, respectively) and using GFAAS (Pd at 247.64 nm, Pt at 265.94 nm). Five types of spent catalyst were analyzed and the standard deviations of repeatability for five parallel samples were less than predicted relative standard deviations (PRSD%) calculated using Horvitz’s equation for all the analyzed samples. |
format | Online Article Text |
id | pubmed-7697727 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-76977272020-11-29 Performance Parameters of Inductively Coupled Plasma Optical Emission Spectrometry and Graphite Furnace Atomic Absorption Spectrometry Techniques for Pd and Pt Determination in Automotive Catalysts Senila, Marin Cadar, Oana Senila, Lacrimioara Böringer, Sarah Seaudeau-Pirouley, Karine Ruiu, Andrea Lacroix-Desmazes, Patrick Materials (Basel) Article Palladium (Pd) and platinum (Pt) are extensively used as catalysts in the petrochemical and automotive industries, and due to high demand for them on the market, their recycling from spent supported catalysts is clearly needed. To assess the content of Pd and Pt in catalysts in order to establish their commercial value or to evaluate the recovery efficiency of technologies used for recycling, reliable analytical methods for determination of these elements are required. Spectrometric methods, such as inductively coupled plasma optical emission spectrometry (ICP-OES) and graphite furnace atomic absorption spectrometry (GFAAS) are powerful tools that can be employed for the determination of Pd and Pt in various sample matrices. However, these methods allow only the injection of liquid samples. In this regard, the digestion of solid sample by microwave-assisted acid extraction procedures at high pressures and temperatures is often used. In this study, a microwave acid digestion method was optimized for the extraction of Pd and Pt from spent catalysts, using a four-step program, at a maximum 200 °C. The resulting solutions were analyzed using ICP-OES, at two different wavelengths for each metal (Pd at 340.458 and 363.470 nm, and Pt at 265.945 and 214.423 nm, respectively) and using GFAAS (Pd at 247.64 nm, Pt at 265.94 nm). Five types of spent catalyst were analyzed and the standard deviations of repeatability for five parallel samples were less than predicted relative standard deviations (PRSD%) calculated using Horvitz’s equation for all the analyzed samples. MDPI 2020-11-14 /pmc/articles/PMC7697727/ /pubmed/33202565 http://dx.doi.org/10.3390/ma13225136 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Senila, Marin Cadar, Oana Senila, Lacrimioara Böringer, Sarah Seaudeau-Pirouley, Karine Ruiu, Andrea Lacroix-Desmazes, Patrick Performance Parameters of Inductively Coupled Plasma Optical Emission Spectrometry and Graphite Furnace Atomic Absorption Spectrometry Techniques for Pd and Pt Determination in Automotive Catalysts |
title | Performance Parameters of Inductively Coupled Plasma Optical Emission Spectrometry and Graphite Furnace Atomic Absorption Spectrometry Techniques for Pd and Pt Determination in Automotive Catalysts |
title_full | Performance Parameters of Inductively Coupled Plasma Optical Emission Spectrometry and Graphite Furnace Atomic Absorption Spectrometry Techniques for Pd and Pt Determination in Automotive Catalysts |
title_fullStr | Performance Parameters of Inductively Coupled Plasma Optical Emission Spectrometry and Graphite Furnace Atomic Absorption Spectrometry Techniques for Pd and Pt Determination in Automotive Catalysts |
title_full_unstemmed | Performance Parameters of Inductively Coupled Plasma Optical Emission Spectrometry and Graphite Furnace Atomic Absorption Spectrometry Techniques for Pd and Pt Determination in Automotive Catalysts |
title_short | Performance Parameters of Inductively Coupled Plasma Optical Emission Spectrometry and Graphite Furnace Atomic Absorption Spectrometry Techniques for Pd and Pt Determination in Automotive Catalysts |
title_sort | performance parameters of inductively coupled plasma optical emission spectrometry and graphite furnace atomic absorption spectrometry techniques for pd and pt determination in automotive catalysts |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7697727/ https://www.ncbi.nlm.nih.gov/pubmed/33202565 http://dx.doi.org/10.3390/ma13225136 |
work_keys_str_mv | AT senilamarin performanceparametersofinductivelycoupledplasmaopticalemissionspectrometryandgraphitefurnaceatomicabsorptionspectrometrytechniquesforpdandptdeterminationinautomotivecatalysts AT cadaroana performanceparametersofinductivelycoupledplasmaopticalemissionspectrometryandgraphitefurnaceatomicabsorptionspectrometrytechniquesforpdandptdeterminationinautomotivecatalysts AT senilalacrimioara performanceparametersofinductivelycoupledplasmaopticalemissionspectrometryandgraphitefurnaceatomicabsorptionspectrometrytechniquesforpdandptdeterminationinautomotivecatalysts AT boringersarah performanceparametersofinductivelycoupledplasmaopticalemissionspectrometryandgraphitefurnaceatomicabsorptionspectrometrytechniquesforpdandptdeterminationinautomotivecatalysts AT seaudeaupirouleykarine performanceparametersofinductivelycoupledplasmaopticalemissionspectrometryandgraphitefurnaceatomicabsorptionspectrometrytechniquesforpdandptdeterminationinautomotivecatalysts AT ruiuandrea performanceparametersofinductivelycoupledplasmaopticalemissionspectrometryandgraphitefurnaceatomicabsorptionspectrometrytechniquesforpdandptdeterminationinautomotivecatalysts AT lacroixdesmazespatrick performanceparametersofinductivelycoupledplasmaopticalemissionspectrometryandgraphitefurnaceatomicabsorptionspectrometrytechniquesforpdandptdeterminationinautomotivecatalysts |