Cargando…
An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector
An improved passive CR-39-based direct (222)Rn/(220)Rn progeny detector with 3 detection channels was designed and tested in this study to measure and calculate equilibrium equivalent concentration (EEC) of both (222)Rn and (220)Rn without the equilibrium factor. A theoretical model was established...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7699185/ https://www.ncbi.nlm.nih.gov/pubmed/33218216 http://dx.doi.org/10.3390/ijerph17228569 |
_version_ | 1783615991050141696 |
---|---|
author | Hu, Jun Yang, Guosheng Kranrod, Chutima Iwaoka, Kazuki Hosoda, Masahiro Tokonami, Shinji |
author_facet | Hu, Jun Yang, Guosheng Kranrod, Chutima Iwaoka, Kazuki Hosoda, Masahiro Tokonami, Shinji |
author_sort | Hu, Jun |
collection | PubMed |
description | An improved passive CR-39-based direct (222)Rn/(220)Rn progeny detector with 3 detection channels was designed and tested in this study to measure and calculate equilibrium equivalent concentration (EEC) of both (222)Rn and (220)Rn without the equilibrium factor. A theoretical model was established to calculate the EEC with optimization. Subsequently, an exposure experiment was carried out to test the performance of this detector, and we compared the chamber experiment and the theoretical model by estimating and measuring various parameters. The deposition flux of progeny derived from the prediction agreed well with the value measured in the exposure chamber. The energy-weighted net track density (NTD) measured by this detector is much more reliable to reflect the linear relation between NTD and time-integrated EEC. Since the detector is sensitive to the exposure environmental condition, it is recommended to apply the detector to measure the EEC after its calibration in a typical indoor environment. |
format | Online Article Text |
id | pubmed-7699185 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-76991852020-11-29 An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector Hu, Jun Yang, Guosheng Kranrod, Chutima Iwaoka, Kazuki Hosoda, Masahiro Tokonami, Shinji Int J Environ Res Public Health Article An improved passive CR-39-based direct (222)Rn/(220)Rn progeny detector with 3 detection channels was designed and tested in this study to measure and calculate equilibrium equivalent concentration (EEC) of both (222)Rn and (220)Rn without the equilibrium factor. A theoretical model was established to calculate the EEC with optimization. Subsequently, an exposure experiment was carried out to test the performance of this detector, and we compared the chamber experiment and the theoretical model by estimating and measuring various parameters. The deposition flux of progeny derived from the prediction agreed well with the value measured in the exposure chamber. The energy-weighted net track density (NTD) measured by this detector is much more reliable to reflect the linear relation between NTD and time-integrated EEC. Since the detector is sensitive to the exposure environmental condition, it is recommended to apply the detector to measure the EEC after its calibration in a typical indoor environment. MDPI 2020-11-18 2020-11 /pmc/articles/PMC7699185/ /pubmed/33218216 http://dx.doi.org/10.3390/ijerph17228569 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hu, Jun Yang, Guosheng Kranrod, Chutima Iwaoka, Kazuki Hosoda, Masahiro Tokonami, Shinji An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector |
title | An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector |
title_full | An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector |
title_fullStr | An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector |
title_full_unstemmed | An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector |
title_short | An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector |
title_sort | improved passive cr-39-based direct (222)rn/(220)rn progeny detector |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7699185/ https://www.ncbi.nlm.nih.gov/pubmed/33218216 http://dx.doi.org/10.3390/ijerph17228569 |
work_keys_str_mv | AT hujun animprovedpassivecr39baseddirect222rn220rnprogenydetector AT yangguosheng animprovedpassivecr39baseddirect222rn220rnprogenydetector AT kranrodchutima animprovedpassivecr39baseddirect222rn220rnprogenydetector AT iwaokakazuki animprovedpassivecr39baseddirect222rn220rnprogenydetector AT hosodamasahiro animprovedpassivecr39baseddirect222rn220rnprogenydetector AT tokonamishinji animprovedpassivecr39baseddirect222rn220rnprogenydetector AT hujun improvedpassivecr39baseddirect222rn220rnprogenydetector AT yangguosheng improvedpassivecr39baseddirect222rn220rnprogenydetector AT kranrodchutima improvedpassivecr39baseddirect222rn220rnprogenydetector AT iwaokakazuki improvedpassivecr39baseddirect222rn220rnprogenydetector AT hosodamasahiro improvedpassivecr39baseddirect222rn220rnprogenydetector AT tokonamishinji improvedpassivecr39baseddirect222rn220rnprogenydetector |