An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector

An improved passive CR-39-based direct (222)Rn/(220)Rn progeny detector with 3 detection channels was designed and tested in this study to measure and calculate equilibrium equivalent concentration (EEC) of both (222)Rn and (220)Rn without the equilibrium factor. A theoretical model was established...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Jun, Yang, Guosheng, Kranrod, Chutima, Iwaoka, Kazuki, Hosoda, Masahiro, Tokonami, Shinji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7699185/
https://www.ncbi.nlm.nih.gov/pubmed/33218216
http://dx.doi.org/10.3390/ijerph17228569
_version_ 1783615991050141696
author Hu, Jun
Yang, Guosheng
Kranrod, Chutima
Iwaoka, Kazuki
Hosoda, Masahiro
Tokonami, Shinji
author_facet Hu, Jun
Yang, Guosheng
Kranrod, Chutima
Iwaoka, Kazuki
Hosoda, Masahiro
Tokonami, Shinji
author_sort Hu, Jun
collection PubMed
description An improved passive CR-39-based direct (222)Rn/(220)Rn progeny detector with 3 detection channels was designed and tested in this study to measure and calculate equilibrium equivalent concentration (EEC) of both (222)Rn and (220)Rn without the equilibrium factor. A theoretical model was established to calculate the EEC with optimization. Subsequently, an exposure experiment was carried out to test the performance of this detector, and we compared the chamber experiment and the theoretical model by estimating and measuring various parameters. The deposition flux of progeny derived from the prediction agreed well with the value measured in the exposure chamber. The energy-weighted net track density (NTD) measured by this detector is much more reliable to reflect the linear relation between NTD and time-integrated EEC. Since the detector is sensitive to the exposure environmental condition, it is recommended to apply the detector to measure the EEC after its calibration in a typical indoor environment.
format Online
Article
Text
id pubmed-7699185
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-76991852020-11-29 An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector Hu, Jun Yang, Guosheng Kranrod, Chutima Iwaoka, Kazuki Hosoda, Masahiro Tokonami, Shinji Int J Environ Res Public Health Article An improved passive CR-39-based direct (222)Rn/(220)Rn progeny detector with 3 detection channels was designed and tested in this study to measure and calculate equilibrium equivalent concentration (EEC) of both (222)Rn and (220)Rn without the equilibrium factor. A theoretical model was established to calculate the EEC with optimization. Subsequently, an exposure experiment was carried out to test the performance of this detector, and we compared the chamber experiment and the theoretical model by estimating and measuring various parameters. The deposition flux of progeny derived from the prediction agreed well with the value measured in the exposure chamber. The energy-weighted net track density (NTD) measured by this detector is much more reliable to reflect the linear relation between NTD and time-integrated EEC. Since the detector is sensitive to the exposure environmental condition, it is recommended to apply the detector to measure the EEC after its calibration in a typical indoor environment. MDPI 2020-11-18 2020-11 /pmc/articles/PMC7699185/ /pubmed/33218216 http://dx.doi.org/10.3390/ijerph17228569 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hu, Jun
Yang, Guosheng
Kranrod, Chutima
Iwaoka, Kazuki
Hosoda, Masahiro
Tokonami, Shinji
An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector
title An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector
title_full An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector
title_fullStr An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector
title_full_unstemmed An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector
title_short An Improved Passive CR-39-Based Direct (222)Rn/(220)Rn Progeny Detector
title_sort improved passive cr-39-based direct (222)rn/(220)rn progeny detector
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7699185/
https://www.ncbi.nlm.nih.gov/pubmed/33218216
http://dx.doi.org/10.3390/ijerph17228569
work_keys_str_mv AT hujun animprovedpassivecr39baseddirect222rn220rnprogenydetector
AT yangguosheng animprovedpassivecr39baseddirect222rn220rnprogenydetector
AT kranrodchutima animprovedpassivecr39baseddirect222rn220rnprogenydetector
AT iwaokakazuki animprovedpassivecr39baseddirect222rn220rnprogenydetector
AT hosodamasahiro animprovedpassivecr39baseddirect222rn220rnprogenydetector
AT tokonamishinji animprovedpassivecr39baseddirect222rn220rnprogenydetector
AT hujun improvedpassivecr39baseddirect222rn220rnprogenydetector
AT yangguosheng improvedpassivecr39baseddirect222rn220rnprogenydetector
AT kranrodchutima improvedpassivecr39baseddirect222rn220rnprogenydetector
AT iwaokakazuki improvedpassivecr39baseddirect222rn220rnprogenydetector
AT hosodamasahiro improvedpassivecr39baseddirect222rn220rnprogenydetector
AT tokonamishinji improvedpassivecr39baseddirect222rn220rnprogenydetector