Cargando…
Predictors and Biomarkers of Subclinical Leaflet Thrombosis after Transcatheter Aortic Valve Implantation
Transcatheter aortic valve implantation (TAVI) is a recent revolutionary treatment for high-risk patients with severe aortic stenosis who are not suitable for surgery, expanding to intermediate and low-risk patients. Valve leaflet thrombosis (LT) is a potentially fatal complication after TAVI. The i...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700436/ https://www.ncbi.nlm.nih.gov/pubmed/33233321 http://dx.doi.org/10.3390/jcm9113742 |
_version_ | 1783616279826923520 |
---|---|
author | Pieniak, Katarzyna Jędrzejczyk, Szymon Domaszk, Olaf Grodecki, Kajetan Rymuza, Bartosz Huczek, Zenon Kochman, Janusz Filipiak, Krzysztof J. Gąsecka, Aleksandra |
author_facet | Pieniak, Katarzyna Jędrzejczyk, Szymon Domaszk, Olaf Grodecki, Kajetan Rymuza, Bartosz Huczek, Zenon Kochman, Janusz Filipiak, Krzysztof J. Gąsecka, Aleksandra |
author_sort | Pieniak, Katarzyna |
collection | PubMed |
description | Transcatheter aortic valve implantation (TAVI) is a recent revolutionary treatment for high-risk patients with severe aortic stenosis who are not suitable for surgery, expanding to intermediate and low-risk patients. Valve leaflet thrombosis (LT) is a potentially fatal complication after TAVI. The incidence of subclinical LT is as high as 25% among patients in the first year after TAVI. Subclinical LT may evolve into symptomatic thrombosis or lead to premature bioprosthesis degeneration, increasing the risk of neurological complications. Because imaging-based methods have limited sensitivity to detect subclinical LT, there is an urgent need for predictors and biomarkers that would make it possible to predict LT after TAVI. Here, we summarize recent data regarding (i) patient-related, (ii) procedure-related, (iii) blood-based and (iv) imaging predictors and biomarkers which might be useful for the early diagnosis of subclinical LT after TAVI. Prevention of LT might offer an opportunity to improve risk stratification and tailor therapy after TAVI. |
format | Online Article Text |
id | pubmed-7700436 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77004362020-11-30 Predictors and Biomarkers of Subclinical Leaflet Thrombosis after Transcatheter Aortic Valve Implantation Pieniak, Katarzyna Jędrzejczyk, Szymon Domaszk, Olaf Grodecki, Kajetan Rymuza, Bartosz Huczek, Zenon Kochman, Janusz Filipiak, Krzysztof J. Gąsecka, Aleksandra J Clin Med Review Transcatheter aortic valve implantation (TAVI) is a recent revolutionary treatment for high-risk patients with severe aortic stenosis who are not suitable for surgery, expanding to intermediate and low-risk patients. Valve leaflet thrombosis (LT) is a potentially fatal complication after TAVI. The incidence of subclinical LT is as high as 25% among patients in the first year after TAVI. Subclinical LT may evolve into symptomatic thrombosis or lead to premature bioprosthesis degeneration, increasing the risk of neurological complications. Because imaging-based methods have limited sensitivity to detect subclinical LT, there is an urgent need for predictors and biomarkers that would make it possible to predict LT after TAVI. Here, we summarize recent data regarding (i) patient-related, (ii) procedure-related, (iii) blood-based and (iv) imaging predictors and biomarkers which might be useful for the early diagnosis of subclinical LT after TAVI. Prevention of LT might offer an opportunity to improve risk stratification and tailor therapy after TAVI. MDPI 2020-11-21 /pmc/articles/PMC7700436/ /pubmed/33233321 http://dx.doi.org/10.3390/jcm9113742 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Pieniak, Katarzyna Jędrzejczyk, Szymon Domaszk, Olaf Grodecki, Kajetan Rymuza, Bartosz Huczek, Zenon Kochman, Janusz Filipiak, Krzysztof J. Gąsecka, Aleksandra Predictors and Biomarkers of Subclinical Leaflet Thrombosis after Transcatheter Aortic Valve Implantation |
title | Predictors and Biomarkers of Subclinical Leaflet Thrombosis after Transcatheter Aortic Valve Implantation |
title_full | Predictors and Biomarkers of Subclinical Leaflet Thrombosis after Transcatheter Aortic Valve Implantation |
title_fullStr | Predictors and Biomarkers of Subclinical Leaflet Thrombosis after Transcatheter Aortic Valve Implantation |
title_full_unstemmed | Predictors and Biomarkers of Subclinical Leaflet Thrombosis after Transcatheter Aortic Valve Implantation |
title_short | Predictors and Biomarkers of Subclinical Leaflet Thrombosis after Transcatheter Aortic Valve Implantation |
title_sort | predictors and biomarkers of subclinical leaflet thrombosis after transcatheter aortic valve implantation |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700436/ https://www.ncbi.nlm.nih.gov/pubmed/33233321 http://dx.doi.org/10.3390/jcm9113742 |
work_keys_str_mv | AT pieniakkatarzyna predictorsandbiomarkersofsubclinicalleafletthrombosisaftertranscatheteraorticvalveimplantation AT jedrzejczykszymon predictorsandbiomarkersofsubclinicalleafletthrombosisaftertranscatheteraorticvalveimplantation AT domaszkolaf predictorsandbiomarkersofsubclinicalleafletthrombosisaftertranscatheteraorticvalveimplantation AT grodeckikajetan predictorsandbiomarkersofsubclinicalleafletthrombosisaftertranscatheteraorticvalveimplantation AT rymuzabartosz predictorsandbiomarkersofsubclinicalleafletthrombosisaftertranscatheteraorticvalveimplantation AT huczekzenon predictorsandbiomarkersofsubclinicalleafletthrombosisaftertranscatheteraorticvalveimplantation AT kochmanjanusz predictorsandbiomarkersofsubclinicalleafletthrombosisaftertranscatheteraorticvalveimplantation AT filipiakkrzysztofj predictorsandbiomarkersofsubclinicalleafletthrombosisaftertranscatheteraorticvalveimplantation AT gaseckaaleksandra predictorsandbiomarkersofsubclinicalleafletthrombosisaftertranscatheteraorticvalveimplantation |