Cargando…

Simultaneous Determination of Isothiazolinones and Parabens in Cosmetic Products Using Solid-Phase Extraction and Ultra-High Performance Liquid Chromatography/Diode Array Detector

Isothiazolinones methylisothiazolinone (MI) and methylchloroisothiazolinone (MCI), and parabens methylparaben (MP), ethylparaben (EP), propylparaben (PP) and butylparaben (BP) are the most common synthetic preservatives. They are all known to be potential skin allergens that lead to contact dermatit...

Descripción completa

Detalles Bibliográficos
Autores principales: Ali, Hazim Mohammed, Alsohaimi, Ibrahim Hotan, Khan, Mohammad Rizwan, Azam, Mohammad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700590/
https://www.ncbi.nlm.nih.gov/pubmed/33266462
http://dx.doi.org/10.3390/ph13110412
_version_ 1783616315908423680
author Ali, Hazim Mohammed
Alsohaimi, Ibrahim Hotan
Khan, Mohammad Rizwan
Azam, Mohammad
author_facet Ali, Hazim Mohammed
Alsohaimi, Ibrahim Hotan
Khan, Mohammad Rizwan
Azam, Mohammad
author_sort Ali, Hazim Mohammed
collection PubMed
description Isothiazolinones methylisothiazolinone (MI) and methylchloroisothiazolinone (MCI), and parabens methylparaben (MP), ethylparaben (EP), propylparaben (PP) and butylparaben (BP) are the most common synthetic preservatives. They are all known to be potential skin allergens that lead to contact dermatitis. Thus, the identification of these unsafe chemicals in cosmetic products is of high importance. In the present study, solid-phase extraction (SPE) based on HyperSep reversed-phase C8/benzene sulfonic acid ion exchanger (HyperSep C8/BSAIE) and Sep-Pak C18 sorbents, and ultra-high performance liquid chromatography/diode array detector (UHPLC/DAD) were optimized for the simultaneous determination of MI, MCI, MP, EP, PP and BP in cosmetic products. HyperSep C8/BSAIE and UHPLC/DAD with the eluting solvent mixture (acetonitrile/methanol, 2:1, v/v) and detection wavelength (255 nm) were found to be the optimal conditions, respectively. The method illustrates the excellent linearity range (0.008–20 μg/mL) with coefficient of determination (R(2), 0.997–0.999), limits of detection (LOD, 0.001–0.002 μg/mL), precision in terms of relative standard deviation (RSD < 3%, intra-day and <6%, inter-day) when examining a standard mixture at low (0.07 µg/mL), medium (3 µg/mL) and high (15 µg/mL) concentrations. A total of 31 cosmetic samples were studied, achieving concentrations (MI, not detected (nd)-0.89 µg/g), (MCI, nd-0.62 µg/g), (MP, nd-6.53 µg/g), (EP, nd-0.90 µg/g), (PP, nd-9.69 µg/g) and (BP, nd-17.80 µg/g). Recovery values ranged from 92.33 to 101.43% depending on the types of sample. To our knowledge, this is the first specific method which covers the theme and describes background amounts of such preservatives in cosmetics.
format Online
Article
Text
id pubmed-7700590
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77005902020-11-30 Simultaneous Determination of Isothiazolinones and Parabens in Cosmetic Products Using Solid-Phase Extraction and Ultra-High Performance Liquid Chromatography/Diode Array Detector Ali, Hazim Mohammed Alsohaimi, Ibrahim Hotan Khan, Mohammad Rizwan Azam, Mohammad Pharmaceuticals (Basel) Article Isothiazolinones methylisothiazolinone (MI) and methylchloroisothiazolinone (MCI), and parabens methylparaben (MP), ethylparaben (EP), propylparaben (PP) and butylparaben (BP) are the most common synthetic preservatives. They are all known to be potential skin allergens that lead to contact dermatitis. Thus, the identification of these unsafe chemicals in cosmetic products is of high importance. In the present study, solid-phase extraction (SPE) based on HyperSep reversed-phase C8/benzene sulfonic acid ion exchanger (HyperSep C8/BSAIE) and Sep-Pak C18 sorbents, and ultra-high performance liquid chromatography/diode array detector (UHPLC/DAD) were optimized for the simultaneous determination of MI, MCI, MP, EP, PP and BP in cosmetic products. HyperSep C8/BSAIE and UHPLC/DAD with the eluting solvent mixture (acetonitrile/methanol, 2:1, v/v) and detection wavelength (255 nm) were found to be the optimal conditions, respectively. The method illustrates the excellent linearity range (0.008–20 μg/mL) with coefficient of determination (R(2), 0.997–0.999), limits of detection (LOD, 0.001–0.002 μg/mL), precision in terms of relative standard deviation (RSD < 3%, intra-day and <6%, inter-day) when examining a standard mixture at low (0.07 µg/mL), medium (3 µg/mL) and high (15 µg/mL) concentrations. A total of 31 cosmetic samples were studied, achieving concentrations (MI, not detected (nd)-0.89 µg/g), (MCI, nd-0.62 µg/g), (MP, nd-6.53 µg/g), (EP, nd-0.90 µg/g), (PP, nd-9.69 µg/g) and (BP, nd-17.80 µg/g). Recovery values ranged from 92.33 to 101.43% depending on the types of sample. To our knowledge, this is the first specific method which covers the theme and describes background amounts of such preservatives in cosmetics. MDPI 2020-11-22 /pmc/articles/PMC7700590/ /pubmed/33266462 http://dx.doi.org/10.3390/ph13110412 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ali, Hazim Mohammed
Alsohaimi, Ibrahim Hotan
Khan, Mohammad Rizwan
Azam, Mohammad
Simultaneous Determination of Isothiazolinones and Parabens in Cosmetic Products Using Solid-Phase Extraction and Ultra-High Performance Liquid Chromatography/Diode Array Detector
title Simultaneous Determination of Isothiazolinones and Parabens in Cosmetic Products Using Solid-Phase Extraction and Ultra-High Performance Liquid Chromatography/Diode Array Detector
title_full Simultaneous Determination of Isothiazolinones and Parabens in Cosmetic Products Using Solid-Phase Extraction and Ultra-High Performance Liquid Chromatography/Diode Array Detector
title_fullStr Simultaneous Determination of Isothiazolinones and Parabens in Cosmetic Products Using Solid-Phase Extraction and Ultra-High Performance Liquid Chromatography/Diode Array Detector
title_full_unstemmed Simultaneous Determination of Isothiazolinones and Parabens in Cosmetic Products Using Solid-Phase Extraction and Ultra-High Performance Liquid Chromatography/Diode Array Detector
title_short Simultaneous Determination of Isothiazolinones and Parabens in Cosmetic Products Using Solid-Phase Extraction and Ultra-High Performance Liquid Chromatography/Diode Array Detector
title_sort simultaneous determination of isothiazolinones and parabens in cosmetic products using solid-phase extraction and ultra-high performance liquid chromatography/diode array detector
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700590/
https://www.ncbi.nlm.nih.gov/pubmed/33266462
http://dx.doi.org/10.3390/ph13110412
work_keys_str_mv AT alihazimmohammed simultaneousdeterminationofisothiazolinonesandparabensincosmeticproductsusingsolidphaseextractionandultrahighperformanceliquidchromatographydiodearraydetector
AT alsohaimiibrahimhotan simultaneousdeterminationofisothiazolinonesandparabensincosmeticproductsusingsolidphaseextractionandultrahighperformanceliquidchromatographydiodearraydetector
AT khanmohammadrizwan simultaneousdeterminationofisothiazolinonesandparabensincosmeticproductsusingsolidphaseextractionandultrahighperformanceliquidchromatographydiodearraydetector
AT azammohammad simultaneousdeterminationofisothiazolinonesandparabensincosmeticproductsusingsolidphaseextractionandultrahighperformanceliquidchromatographydiodearraydetector