Cargando…

The Body’s Cellular and Molecular Response to Protein-Coated Medical Device Implants: A Review Focused on Fibronectin and BMP Proteins

Recent years have seen a marked rise in implantation into the body of a great variety of devices: hip, knee, and shoulder replacements, pacemakers, meshes, glucose sensors, and many others. Cochlear and retinal implants are being developed to restore hearing and sight. After surgery to implant a dev...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Yi-Fan, Goodheart, Clyde, Rua, Diego
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700595/
https://www.ncbi.nlm.nih.gov/pubmed/33238458
http://dx.doi.org/10.3390/ijms21228853
_version_ 1783616317070245888
author Chen, Yi-Fan
Goodheart, Clyde
Rua, Diego
author_facet Chen, Yi-Fan
Goodheart, Clyde
Rua, Diego
author_sort Chen, Yi-Fan
collection PubMed
description Recent years have seen a marked rise in implantation into the body of a great variety of devices: hip, knee, and shoulder replacements, pacemakers, meshes, glucose sensors, and many others. Cochlear and retinal implants are being developed to restore hearing and sight. After surgery to implant a device, adjacent cells interact with the implant and release molecular signals that result in attraction, infiltration of the tissue, and attachment to the implant of various cell types including monocytes, macrophages, and platelets. These cells release additional signaling molecules (chemokines and cytokines) that recruit tissue repair cells to the device site. Some implants fail and require additional revision surgery that is traumatic for the patient and expensive for the payer. This review examines the literature for evidence to support the possibility that fibronectins and BMPs could be coated on the implants as part of the manufacturing process so that the proteins could be released into the tissue surrounding the implant and improve the rate of successful implantation.
format Online
Article
Text
id pubmed-7700595
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77005952020-11-30 The Body’s Cellular and Molecular Response to Protein-Coated Medical Device Implants: A Review Focused on Fibronectin and BMP Proteins Chen, Yi-Fan Goodheart, Clyde Rua, Diego Int J Mol Sci Review Recent years have seen a marked rise in implantation into the body of a great variety of devices: hip, knee, and shoulder replacements, pacemakers, meshes, glucose sensors, and many others. Cochlear and retinal implants are being developed to restore hearing and sight. After surgery to implant a device, adjacent cells interact with the implant and release molecular signals that result in attraction, infiltration of the tissue, and attachment to the implant of various cell types including monocytes, macrophages, and platelets. These cells release additional signaling molecules (chemokines and cytokines) that recruit tissue repair cells to the device site. Some implants fail and require additional revision surgery that is traumatic for the patient and expensive for the payer. This review examines the literature for evidence to support the possibility that fibronectins and BMPs could be coated on the implants as part of the manufacturing process so that the proteins could be released into the tissue surrounding the implant and improve the rate of successful implantation. MDPI 2020-11-23 /pmc/articles/PMC7700595/ /pubmed/33238458 http://dx.doi.org/10.3390/ijms21228853 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Chen, Yi-Fan
Goodheart, Clyde
Rua, Diego
The Body’s Cellular and Molecular Response to Protein-Coated Medical Device Implants: A Review Focused on Fibronectin and BMP Proteins
title The Body’s Cellular and Molecular Response to Protein-Coated Medical Device Implants: A Review Focused on Fibronectin and BMP Proteins
title_full The Body’s Cellular and Molecular Response to Protein-Coated Medical Device Implants: A Review Focused on Fibronectin and BMP Proteins
title_fullStr The Body’s Cellular and Molecular Response to Protein-Coated Medical Device Implants: A Review Focused on Fibronectin and BMP Proteins
title_full_unstemmed The Body’s Cellular and Molecular Response to Protein-Coated Medical Device Implants: A Review Focused on Fibronectin and BMP Proteins
title_short The Body’s Cellular and Molecular Response to Protein-Coated Medical Device Implants: A Review Focused on Fibronectin and BMP Proteins
title_sort body’s cellular and molecular response to protein-coated medical device implants: a review focused on fibronectin and bmp proteins
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700595/
https://www.ncbi.nlm.nih.gov/pubmed/33238458
http://dx.doi.org/10.3390/ijms21228853
work_keys_str_mv AT chenyifan thebodyscellularandmolecularresponsetoproteincoatedmedicaldeviceimplantsareviewfocusedonfibronectinandbmpproteins
AT goodheartclyde thebodyscellularandmolecularresponsetoproteincoatedmedicaldeviceimplantsareviewfocusedonfibronectinandbmpproteins
AT ruadiego thebodyscellularandmolecularresponsetoproteincoatedmedicaldeviceimplantsareviewfocusedonfibronectinandbmpproteins
AT chenyifan bodyscellularandmolecularresponsetoproteincoatedmedicaldeviceimplantsareviewfocusedonfibronectinandbmpproteins
AT goodheartclyde bodyscellularandmolecularresponsetoproteincoatedmedicaldeviceimplantsareviewfocusedonfibronectinandbmpproteins
AT ruadiego bodyscellularandmolecularresponsetoproteincoatedmedicaldeviceimplantsareviewfocusedonfibronectinandbmpproteins