Cargando…

The diode laser as coadyuvant therapy in the non-surgical conventional treatment of peri-implant mucositis: A systematic review and meta-analysis

BACKGROUND: The present study systematically reviewed randomized controlled trials (RCT) to investigate the effect of diode laser therapy in the management of peri-implant mucositis. MATERIAL AND METHODS: The electronic databases were searched until January 2020. Outcome measures were bleeding on pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Sánchez-Martos, Rebeca, Samman, Andrea, Priami, Mattia, Arias-Herrera, Santiago
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700786/
https://www.ncbi.nlm.nih.gov/pubmed/33282139
http://dx.doi.org/10.4317/jced.57630
_version_ 1783616356795547648
author Sánchez-Martos, Rebeca
Samman, Andrea
Priami, Mattia
Arias-Herrera, Santiago
author_facet Sánchez-Martos, Rebeca
Samman, Andrea
Priami, Mattia
Arias-Herrera, Santiago
author_sort Sánchez-Martos, Rebeca
collection PubMed
description BACKGROUND: The present study systematically reviewed randomized controlled trials (RCT) to investigate the effect of diode laser therapy in the management of peri-implant mucositis. MATERIAL AND METHODS: The electronic databases were searched until January 2020. Outcome measures were bleeding on probing (BOP), plaque index (PI) and probing depth (PD). The addressed PICO question was: Is the diode laser therapy effective reducing the signs of inflammation as an adjunctive element in the non-surgical treatment of peri-implant mucositis?. RESULTS: Eight randomized clinical trials (RCTs) were included in the systematic review for qualitative synthesis and three in the meta-analysis for quantitative synthesis. All studies included in the quantitative synthesis have low risk of bias according to the Cochrane collaborations’ tool. Diode laser as coadyuvant therapy significantly reduced plaque index (SMD: -1.24; -0.47/-1.53) but not in bleeding on probing (SMD: -0.84; -0.31/-1.53) or probing pocket depth (SMD: -1.36; -0.28/-1.69). Non-statistically significant reductions in peri-implant bleeding on probing and in probing pocket depth were also observed in the test groups of most studies included in the meta-analysis. CONCLUSIONS: The results should be interpreted cautiously due to the great heterogeneity in the methodology of the studies included in the systematic review. However the meta-analysis suggests that the use of diode lasers, as an adjunct in conventional non-surgical treatment of peri-implant mucositis, is promising in reducing the clinical signs of peri-implant mucositis, especially reducing the perii-implant plaque index. Key words:Peri-implant diseases, peri-implant mucositis, laser therapy, diode laser.
format Online
Article
Text
id pubmed-7700786
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-77007862020-12-04 The diode laser as coadyuvant therapy in the non-surgical conventional treatment of peri-implant mucositis: A systematic review and meta-analysis Sánchez-Martos, Rebeca Samman, Andrea Priami, Mattia Arias-Herrera, Santiago J Clin Exp Dent Review BACKGROUND: The present study systematically reviewed randomized controlled trials (RCT) to investigate the effect of diode laser therapy in the management of peri-implant mucositis. MATERIAL AND METHODS: The electronic databases were searched until January 2020. Outcome measures were bleeding on probing (BOP), plaque index (PI) and probing depth (PD). The addressed PICO question was: Is the diode laser therapy effective reducing the signs of inflammation as an adjunctive element in the non-surgical treatment of peri-implant mucositis?. RESULTS: Eight randomized clinical trials (RCTs) were included in the systematic review for qualitative synthesis and three in the meta-analysis for quantitative synthesis. All studies included in the quantitative synthesis have low risk of bias according to the Cochrane collaborations’ tool. Diode laser as coadyuvant therapy significantly reduced plaque index (SMD: -1.24; -0.47/-1.53) but not in bleeding on probing (SMD: -0.84; -0.31/-1.53) or probing pocket depth (SMD: -1.36; -0.28/-1.69). Non-statistically significant reductions in peri-implant bleeding on probing and in probing pocket depth were also observed in the test groups of most studies included in the meta-analysis. CONCLUSIONS: The results should be interpreted cautiously due to the great heterogeneity in the methodology of the studies included in the systematic review. However the meta-analysis suggests that the use of diode lasers, as an adjunct in conventional non-surgical treatment of peri-implant mucositis, is promising in reducing the clinical signs of peri-implant mucositis, especially reducing the perii-implant plaque index. Key words:Peri-implant diseases, peri-implant mucositis, laser therapy, diode laser. Medicina Oral S.L. 2020-12-01 /pmc/articles/PMC7700786/ /pubmed/33282139 http://dx.doi.org/10.4317/jced.57630 Text en Copyright: © 2020 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review
Sánchez-Martos, Rebeca
Samman, Andrea
Priami, Mattia
Arias-Herrera, Santiago
The diode laser as coadyuvant therapy in the non-surgical conventional treatment of peri-implant mucositis: A systematic review and meta-analysis
title The diode laser as coadyuvant therapy in the non-surgical conventional treatment of peri-implant mucositis: A systematic review and meta-analysis
title_full The diode laser as coadyuvant therapy in the non-surgical conventional treatment of peri-implant mucositis: A systematic review and meta-analysis
title_fullStr The diode laser as coadyuvant therapy in the non-surgical conventional treatment of peri-implant mucositis: A systematic review and meta-analysis
title_full_unstemmed The diode laser as coadyuvant therapy in the non-surgical conventional treatment of peri-implant mucositis: A systematic review and meta-analysis
title_short The diode laser as coadyuvant therapy in the non-surgical conventional treatment of peri-implant mucositis: A systematic review and meta-analysis
title_sort diode laser as coadyuvant therapy in the non-surgical conventional treatment of peri-implant mucositis: a systematic review and meta-analysis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700786/
https://www.ncbi.nlm.nih.gov/pubmed/33282139
http://dx.doi.org/10.4317/jced.57630
work_keys_str_mv AT sanchezmartosrebeca thediodelaserascoadyuvanttherapyinthenonsurgicalconventionaltreatmentofperiimplantmucositisasystematicreviewandmetaanalysis
AT sammanandrea thediodelaserascoadyuvanttherapyinthenonsurgicalconventionaltreatmentofperiimplantmucositisasystematicreviewandmetaanalysis
AT priamimattia thediodelaserascoadyuvanttherapyinthenonsurgicalconventionaltreatmentofperiimplantmucositisasystematicreviewandmetaanalysis
AT ariasherrerasantiago thediodelaserascoadyuvanttherapyinthenonsurgicalconventionaltreatmentofperiimplantmucositisasystematicreviewandmetaanalysis
AT sanchezmartosrebeca diodelaserascoadyuvanttherapyinthenonsurgicalconventionaltreatmentofperiimplantmucositisasystematicreviewandmetaanalysis
AT sammanandrea diodelaserascoadyuvanttherapyinthenonsurgicalconventionaltreatmentofperiimplantmucositisasystematicreviewandmetaanalysis
AT priamimattia diodelaserascoadyuvanttherapyinthenonsurgicalconventionaltreatmentofperiimplantmucositisasystematicreviewandmetaanalysis
AT ariasherrerasantiago diodelaserascoadyuvanttherapyinthenonsurgicalconventionaltreatmentofperiimplantmucositisasystematicreviewandmetaanalysis