Cargando…
Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams
This study assesses the feasibility of using stereotactic field diode (SFD) as an alternate to gaf chromic films for field output factor (FF) measurement and further evaluating three new detectors for small field dosimetry. Varian 21EX linear accelerator was used to generate 6 and 10 MV beams of nom...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700919/ https://www.ncbi.nlm.nih.gov/pubmed/33078544 http://dx.doi.org/10.1002/acm2.13007 |
_version_ | 1783616383427280896 |
---|---|
author | Gul, Attia Fukuda, Shigekazu Mizuno, Hideyuki Taku, Nakaji Kakakhel, M. Basim Mirza, Sikander M. |
author_facet | Gul, Attia Fukuda, Shigekazu Mizuno, Hideyuki Taku, Nakaji Kakakhel, M. Basim Mirza, Sikander M. |
author_sort | Gul, Attia |
collection | PubMed |
description | This study assesses the feasibility of using stereotactic field diode (SFD) as an alternate to gaf chromic films for field output factor (FF) measurement and further evaluating three new detectors for small field dosimetry. Varian 21EX linear accelerator was used to generate 6 and 10 MV beams of nominal square fields ranging from 0.5 × 0.5 cm(2) to 10 × 10 cm(2). One passive (EBT3 films) and five active detectors including IBA RAZOR diode(RD), SFD, RAZOR nanochamber (RNC), pinpoint chamber (PTW31023), and semiflex chamber (PTW31010) were employed. FFs were measured using films and SFD while beam profiles and percentage depth dose (PDD) distribution were acquired with active detectors. Polarity (k(pol)) and recombination (k(s)) effects of ion chambers were determined and corrected for output ratio measurement. Correction factors (CF) of RD, RNC, and PTW31023 in axial and radial orientation were also measured. Stereotactic field diode measured FFs have shown good agreement with films (with difference of <1%). RD and RNC measured beam profiles were within 3% deviation from the SFD values. Variation in k(pol) with field size for RNC and PTW31023 was up to 4% and 0.4% (for fields ≥ 1 × 1 cm(2)), respectively, while variation in k(s) of PTW31023 was <0.2 %. The maximum values of CF have been calculated to be 5.2%, 2.0%, 13.6%, and 25.5% for RD, RNC, PTW31023‐axial, and PTW31023‐radial respectively. This study concludes that SFD with appropriate CFs as given in TRS 483 may be used for measuring FFs as an alternate to EBT3 films. Whereas RD and RNC may be used for beam profile and PDD measurement in small fields. Considering the limit of usability of 2%, RNC may be used without CF for FF measurement in the smallfields investigated in this study. |
format | Online Article Text |
id | pubmed-7700919 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-77009192020-12-03 Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams Gul, Attia Fukuda, Shigekazu Mizuno, Hideyuki Taku, Nakaji Kakakhel, M. Basim Mirza, Sikander M. J Appl Clin Med Phys Radiation Oncology Physics This study assesses the feasibility of using stereotactic field diode (SFD) as an alternate to gaf chromic films for field output factor (FF) measurement and further evaluating three new detectors for small field dosimetry. Varian 21EX linear accelerator was used to generate 6 and 10 MV beams of nominal square fields ranging from 0.5 × 0.5 cm(2) to 10 × 10 cm(2). One passive (EBT3 films) and five active detectors including IBA RAZOR diode(RD), SFD, RAZOR nanochamber (RNC), pinpoint chamber (PTW31023), and semiflex chamber (PTW31010) were employed. FFs were measured using films and SFD while beam profiles and percentage depth dose (PDD) distribution were acquired with active detectors. Polarity (k(pol)) and recombination (k(s)) effects of ion chambers were determined and corrected for output ratio measurement. Correction factors (CF) of RD, RNC, and PTW31023 in axial and radial orientation were also measured. Stereotactic field diode measured FFs have shown good agreement with films (with difference of <1%). RD and RNC measured beam profiles were within 3% deviation from the SFD values. Variation in k(pol) with field size for RNC and PTW31023 was up to 4% and 0.4% (for fields ≥ 1 × 1 cm(2)), respectively, while variation in k(s) of PTW31023 was <0.2 %. The maximum values of CF have been calculated to be 5.2%, 2.0%, 13.6%, and 25.5% for RD, RNC, PTW31023‐axial, and PTW31023‐radial respectively. This study concludes that SFD with appropriate CFs as given in TRS 483 may be used for measuring FFs as an alternate to EBT3 films. Whereas RD and RNC may be used for beam profile and PDD measurement in small fields. Considering the limit of usability of 2%, RNC may be used without CF for FF measurement in the smallfields investigated in this study. John Wiley and Sons Inc. 2020-10-19 /pmc/articles/PMC7700919/ /pubmed/33078544 http://dx.doi.org/10.1002/acm2.13007 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Gul, Attia Fukuda, Shigekazu Mizuno, Hideyuki Taku, Nakaji Kakakhel, M. Basim Mirza, Sikander M. Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams |
title | Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams |
title_full | Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams |
title_fullStr | Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams |
title_full_unstemmed | Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams |
title_short | Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams |
title_sort | feasibility study of using stereotactic field diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 mv photon beams |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700919/ https://www.ncbi.nlm.nih.gov/pubmed/33078544 http://dx.doi.org/10.1002/acm2.13007 |
work_keys_str_mv | AT gulattia feasibilitystudyofusingstereotacticfielddiodeforfieldoutputfactorsmeasurementandevaluatingthreenewdetectorsforsmallfieldrelativedosimetryof6and10mvphotonbeams AT fukudashigekazu feasibilitystudyofusingstereotacticfielddiodeforfieldoutputfactorsmeasurementandevaluatingthreenewdetectorsforsmallfieldrelativedosimetryof6and10mvphotonbeams AT mizunohideyuki feasibilitystudyofusingstereotacticfielddiodeforfieldoutputfactorsmeasurementandevaluatingthreenewdetectorsforsmallfieldrelativedosimetryof6and10mvphotonbeams AT takunakaji feasibilitystudyofusingstereotacticfielddiodeforfieldoutputfactorsmeasurementandevaluatingthreenewdetectorsforsmallfieldrelativedosimetryof6and10mvphotonbeams AT kakakhelmbasim feasibilitystudyofusingstereotacticfielddiodeforfieldoutputfactorsmeasurementandevaluatingthreenewdetectorsforsmallfieldrelativedosimetryof6and10mvphotonbeams AT mirzasikanderm feasibilitystudyofusingstereotacticfielddiodeforfieldoutputfactorsmeasurementandevaluatingthreenewdetectorsforsmallfieldrelativedosimetryof6and10mvphotonbeams |