Portal dosimetry scripting application programming interface (PDSAPI) for Winston‐Lutz test employing ceramic balls

PURPOSE: Stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments require a high degree of accuracy. Mechanical, imaging, and radiation isocenter coincidence is especially important. As a common method, the Winston‐Lutz (WL) test plays an important role. However, wee...

Descripción completa

Detalles Bibliográficos
Autores principales: Hao, Yao, Schmidt, Matthew C., Wu, Yu, Knutson, Nels C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700922/
https://www.ncbi.nlm.nih.gov/pubmed/33098369
http://dx.doi.org/10.1002/acm2.13043
_version_ 1783616384142409728
author Hao, Yao
Schmidt, Matthew C.
Wu, Yu
Knutson, Nels C.
author_facet Hao, Yao
Schmidt, Matthew C.
Wu, Yu
Knutson, Nels C.
author_sort Hao, Yao
collection PubMed
description PURPOSE: Stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments require a high degree of accuracy. Mechanical, imaging, and radiation isocenter coincidence is especially important. As a common method, the Winston‐Lutz (WL) test plays an important role. However, weekly or daily WL test can be very time consuming. We developed novel methods using Portal Dosimetry Scripting Application Programming Interface (PDSAPI) to facilitate the test as well as documentation. METHODS: Winston‐Lutz PDSAPI was developed and tested on our routine weekly WL imaging. The results were compared against two commercially available software RIT (Radiological Imaging Technology, Colorado Springs, CO) and DoseLab (Varian Medical Systems, Inc. Palo Alto, CA). Two manual methods that served as ground truth were used to verify PDSAPI results. Twenty WL test image data sets (10 fields per tests, and 200 images in total) were analyzed by these five methods in this report. RESULTS: More than 99.5% of WL PDSAPI 1D shifts agreed with each of four other methods within ±0.33 mm, which is roughly the pixel width of a‐Si 1200 portal imager when source to imager distance (SID) is at 100 cm. 1D shifts agreement for ±0.22 mm and 0.11 mm were 96% and 63%, respectively. Same trend was observed for 2D displacement. CONCLUSIONS: Winston‐Lutz PDSAPI delivers similar accuracy as two commercial applications for WL test. This new application can save time spent transferring data and has the potential to implement daily WL test with reasonable test time. It also provides the data storage capability, and enables easy access to imaging and shift data.
format Online
Article
Text
id pubmed-7700922
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-77009222020-12-03 Portal dosimetry scripting application programming interface (PDSAPI) for Winston‐Lutz test employing ceramic balls Hao, Yao Schmidt, Matthew C. Wu, Yu Knutson, Nels C. J Appl Clin Med Phys Technical Notes PURPOSE: Stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments require a high degree of accuracy. Mechanical, imaging, and radiation isocenter coincidence is especially important. As a common method, the Winston‐Lutz (WL) test plays an important role. However, weekly or daily WL test can be very time consuming. We developed novel methods using Portal Dosimetry Scripting Application Programming Interface (PDSAPI) to facilitate the test as well as documentation. METHODS: Winston‐Lutz PDSAPI was developed and tested on our routine weekly WL imaging. The results were compared against two commercially available software RIT (Radiological Imaging Technology, Colorado Springs, CO) and DoseLab (Varian Medical Systems, Inc. Palo Alto, CA). Two manual methods that served as ground truth were used to verify PDSAPI results. Twenty WL test image data sets (10 fields per tests, and 200 images in total) were analyzed by these five methods in this report. RESULTS: More than 99.5% of WL PDSAPI 1D shifts agreed with each of four other methods within ±0.33 mm, which is roughly the pixel width of a‐Si 1200 portal imager when source to imager distance (SID) is at 100 cm. 1D shifts agreement for ±0.22 mm and 0.11 mm were 96% and 63%, respectively. Same trend was observed for 2D displacement. CONCLUSIONS: Winston‐Lutz PDSAPI delivers similar accuracy as two commercial applications for WL test. This new application can save time spent transferring data and has the potential to implement daily WL test with reasonable test time. It also provides the data storage capability, and enables easy access to imaging and shift data. John Wiley and Sons Inc. 2020-10-24 /pmc/articles/PMC7700922/ /pubmed/33098369 http://dx.doi.org/10.1002/acm2.13043 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Notes
Hao, Yao
Schmidt, Matthew C.
Wu, Yu
Knutson, Nels C.
Portal dosimetry scripting application programming interface (PDSAPI) for Winston‐Lutz test employing ceramic balls
title Portal dosimetry scripting application programming interface (PDSAPI) for Winston‐Lutz test employing ceramic balls
title_full Portal dosimetry scripting application programming interface (PDSAPI) for Winston‐Lutz test employing ceramic balls
title_fullStr Portal dosimetry scripting application programming interface (PDSAPI) for Winston‐Lutz test employing ceramic balls
title_full_unstemmed Portal dosimetry scripting application programming interface (PDSAPI) for Winston‐Lutz test employing ceramic balls
title_short Portal dosimetry scripting application programming interface (PDSAPI) for Winston‐Lutz test employing ceramic balls
title_sort portal dosimetry scripting application programming interface (pdsapi) for winston‐lutz test employing ceramic balls
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700922/
https://www.ncbi.nlm.nih.gov/pubmed/33098369
http://dx.doi.org/10.1002/acm2.13043
work_keys_str_mv AT haoyao portaldosimetryscriptingapplicationprogramminginterfacepdsapiforwinstonlutztestemployingceramicballs
AT schmidtmatthewc portaldosimetryscriptingapplicationprogramminginterfacepdsapiforwinstonlutztestemployingceramicballs
AT wuyu portaldosimetryscriptingapplicationprogramminginterfacepdsapiforwinstonlutztestemployingceramicballs
AT knutsonnelsc portaldosimetryscriptingapplicationprogramminginterfacepdsapiforwinstonlutztestemployingceramicballs