Detectability of fiducials’ positions for real‐time target tracking system equipping with a standard linac for multiple fiducial markers
PURPOSE: To investigate the detectability of fiducial markers’ positions for real‐time target tracking system equipping with a standard linac. The hypothesis is that the detectability depends on the type of fiducial marker and the gantry angle of acquired triggered images. METHODS: Three types of ba...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700931/ https://www.ncbi.nlm.nih.gov/pubmed/33058408 http://dx.doi.org/10.1002/acm2.13050 |
_version_ | 1783616386281504768 |
---|---|
author | Ono, Shunsuke Ueda, Yoshihiro Ohira, Shingo Isono, Masaru Sumida, Iori Inui, Shoki Morimoto, Masahiro Ashida, Reiko Miyazaki, Masayoshi Ogawa, Kazuhiko Teshima, Teruki |
author_facet | Ono, Shunsuke Ueda, Yoshihiro Ohira, Shingo Isono, Masaru Sumida, Iori Inui, Shoki Morimoto, Masahiro Ashida, Reiko Miyazaki, Masayoshi Ogawa, Kazuhiko Teshima, Teruki |
author_sort | Ono, Shunsuke |
collection | PubMed |
description | PURPOSE: To investigate the detectability of fiducial markers’ positions for real‐time target tracking system equipping with a standard linac. The hypothesis is that the detectability depends on the type of fiducial marker and the gantry angle of acquired triggered images. METHODS: Three types of ball fiducials and four slim fiducials with lengths of 3 and 5 mm were prepared for this study. Triggered images with three similar fiducials were acquired at every 10° during the conformal arc irradiation to detect the target position. Although only one type of arrangement was prepared for the ball fiducials, a three‐type arrangement was prepared for the slim fiducials, such as parallel, orthogonal, and oblique with 45° to the gantry‐couch direction. To measure the detectability of the real‐time target tracking system for each fiducial and arrangement, detected marker positions were compared with expected marker positions at every angle of acquired triggered images. RESULTS: For the ball‐type fiducial, the maximum difference between the detected marker positions and expected marker positions was 0.3 mm in all directions. For the slim fiducial arranged parallel and oblique with 45°, the maximum difference was 0.4 mm in all directions. When each slim fiducial was arranged orthogonal to the gantry‐couch direction, the maximum difference was 1.5 mm for the length of 3 mm, and 3.2 mm for the length of 5 mm. CONCLUSIONS: The detectability of fiducial markers’ positions for the real‐time target tracking system equipping with a standard linac depends on the form and insertion angles of the fiducials. |
format | Online Article Text |
id | pubmed-7700931 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-77009312020-12-03 Detectability of fiducials’ positions for real‐time target tracking system equipping with a standard linac for multiple fiducial markers Ono, Shunsuke Ueda, Yoshihiro Ohira, Shingo Isono, Masaru Sumida, Iori Inui, Shoki Morimoto, Masahiro Ashida, Reiko Miyazaki, Masayoshi Ogawa, Kazuhiko Teshima, Teruki J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: To investigate the detectability of fiducial markers’ positions for real‐time target tracking system equipping with a standard linac. The hypothesis is that the detectability depends on the type of fiducial marker and the gantry angle of acquired triggered images. METHODS: Three types of ball fiducials and four slim fiducials with lengths of 3 and 5 mm were prepared for this study. Triggered images with three similar fiducials were acquired at every 10° during the conformal arc irradiation to detect the target position. Although only one type of arrangement was prepared for the ball fiducials, a three‐type arrangement was prepared for the slim fiducials, such as parallel, orthogonal, and oblique with 45° to the gantry‐couch direction. To measure the detectability of the real‐time target tracking system for each fiducial and arrangement, detected marker positions were compared with expected marker positions at every angle of acquired triggered images. RESULTS: For the ball‐type fiducial, the maximum difference between the detected marker positions and expected marker positions was 0.3 mm in all directions. For the slim fiducial arranged parallel and oblique with 45°, the maximum difference was 0.4 mm in all directions. When each slim fiducial was arranged orthogonal to the gantry‐couch direction, the maximum difference was 1.5 mm for the length of 3 mm, and 3.2 mm for the length of 5 mm. CONCLUSIONS: The detectability of fiducial markers’ positions for the real‐time target tracking system equipping with a standard linac depends on the form and insertion angles of the fiducials. John Wiley and Sons Inc. 2020-10-15 /pmc/articles/PMC7700931/ /pubmed/33058408 http://dx.doi.org/10.1002/acm2.13050 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Ono, Shunsuke Ueda, Yoshihiro Ohira, Shingo Isono, Masaru Sumida, Iori Inui, Shoki Morimoto, Masahiro Ashida, Reiko Miyazaki, Masayoshi Ogawa, Kazuhiko Teshima, Teruki Detectability of fiducials’ positions for real‐time target tracking system equipping with a standard linac for multiple fiducial markers |
title | Detectability of fiducials’ positions for real‐time target tracking system equipping with a standard linac for multiple fiducial markers |
title_full | Detectability of fiducials’ positions for real‐time target tracking system equipping with a standard linac for multiple fiducial markers |
title_fullStr | Detectability of fiducials’ positions for real‐time target tracking system equipping with a standard linac for multiple fiducial markers |
title_full_unstemmed | Detectability of fiducials’ positions for real‐time target tracking system equipping with a standard linac for multiple fiducial markers |
title_short | Detectability of fiducials’ positions for real‐time target tracking system equipping with a standard linac for multiple fiducial markers |
title_sort | detectability of fiducials’ positions for real‐time target tracking system equipping with a standard linac for multiple fiducial markers |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700931/ https://www.ncbi.nlm.nih.gov/pubmed/33058408 http://dx.doi.org/10.1002/acm2.13050 |
work_keys_str_mv | AT onoshunsuke detectabilityoffiducialspositionsforrealtimetargettrackingsystemequippingwithastandardlinacformultiplefiducialmarkers AT uedayoshihiro detectabilityoffiducialspositionsforrealtimetargettrackingsystemequippingwithastandardlinacformultiplefiducialmarkers AT ohirashingo detectabilityoffiducialspositionsforrealtimetargettrackingsystemequippingwithastandardlinacformultiplefiducialmarkers AT isonomasaru detectabilityoffiducialspositionsforrealtimetargettrackingsystemequippingwithastandardlinacformultiplefiducialmarkers AT sumidaiori detectabilityoffiducialspositionsforrealtimetargettrackingsystemequippingwithastandardlinacformultiplefiducialmarkers AT inuishoki detectabilityoffiducialspositionsforrealtimetargettrackingsystemequippingwithastandardlinacformultiplefiducialmarkers AT morimotomasahiro detectabilityoffiducialspositionsforrealtimetargettrackingsystemequippingwithastandardlinacformultiplefiducialmarkers AT ashidareiko detectabilityoffiducialspositionsforrealtimetargettrackingsystemequippingwithastandardlinacformultiplefiducialmarkers AT miyazakimasayoshi detectabilityoffiducialspositionsforrealtimetargettrackingsystemequippingwithastandardlinacformultiplefiducialmarkers AT ogawakazuhiko detectabilityoffiducialspositionsforrealtimetargettrackingsystemequippingwithastandardlinacformultiplefiducialmarkers AT teshimateruki detectabilityoffiducialspositionsforrealtimetargettrackingsystemequippingwithastandardlinacformultiplefiducialmarkers |