Cargando…

Predictive value of Excel forms based on an automatic calculation of dose equivalent in 2 Gy per fraction in adaptive brachytherapy for cervical cancer

PURPOSE: External beam radiotherapy (EBRT) combined with brachytherapy (BT) is the standard mode of radical radiotherapy for locally advanced cervical cancer. The cumulative equivalent doses in 2 Gy per fraction (EQD(2)) is an important basis for estimating the probability of local control of tumors...

Descripción completa

Detalles Bibliográficos
Autores principales: Cheng, Guanghui, Mu, Xin, Liu, Ying, Mao, Zhuang, Zhao, Hongfu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7701924/
https://www.ncbi.nlm.nih.gov/pubmed/33299434
http://dx.doi.org/10.5114/jcb.2020.100378
_version_ 1783616510994939904
author Cheng, Guanghui
Mu, Xin
Liu, Ying
Mao, Zhuang
Zhao, Hongfu
author_facet Cheng, Guanghui
Mu, Xin
Liu, Ying
Mao, Zhuang
Zhao, Hongfu
author_sort Cheng, Guanghui
collection PubMed
description PURPOSE: External beam radiotherapy (EBRT) combined with brachytherapy (BT) is the standard mode of radical radiotherapy for locally advanced cervical cancer. The cumulative equivalent doses in 2 Gy per fraction (EQD(2)) is an important basis for estimating the probability of local control of tumors and monitoring the occurrence of side effects in normal tissues. The purpose of this study was to explore the predictive value of Excel forms based on an automatic calculation in radical adaptive BT for cervical cancer. MATERIAL AND METHODS: A retrospective analysis of 119 patients suffering from cervical cancer, treated with radical radiotherapy. All patients were treated with EBRT and adaptive BT. EBRT prescribed dose was 42.0-50.4 Gy in 21-28 fractions. BT nominal prescribed dose was 28 Gy in 4 fractions, separated by one week. Total EQD(2) prediction at nth (n = 1-3) BT (TEPB(n)) or actual cumulative EQD(2) (ACEQD(2)) can be calculated automatically by inputting the physical dose based on an in-house designed application. The relationship between TEPB(n) and ACEQD(2) was evaluated, and the predictive value of Excel forms based on the automatic calculation was analyzed. RESULTS: For the volume of high-risk clinical target, there was a significant decrease between BT1 and BT2. Similarly, for the volume of intermediate-risk clinical target, there was a significant decrease between BT2 and BT3. The sensitivity ranges of TEPB(1), TEPB(2), and TEPB(3) prediction were 74.5-91.3%, 83.7-95.7%, and 92.9-99.1%, respectively, and the specificity ranges were 46.7-80.0%, 53.3-90.5%, and 66.7-90.5%, respectively. CONCLUSIONS: The in-house designed application has the function of quickly reading dose-volume histogram (DVH) parameters from the treatment planning system, which allows for balance between the total dose to target volumes and organs at risk (OARs). Excel forms based on EQD(2) automatic calculation presents high predictive accuracy.
format Online
Article
Text
id pubmed-7701924
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-77019242020-12-08 Predictive value of Excel forms based on an automatic calculation of dose equivalent in 2 Gy per fraction in adaptive brachytherapy for cervical cancer Cheng, Guanghui Mu, Xin Liu, Ying Mao, Zhuang Zhao, Hongfu J Contemp Brachytherapy Original Paper PURPOSE: External beam radiotherapy (EBRT) combined with brachytherapy (BT) is the standard mode of radical radiotherapy for locally advanced cervical cancer. The cumulative equivalent doses in 2 Gy per fraction (EQD(2)) is an important basis for estimating the probability of local control of tumors and monitoring the occurrence of side effects in normal tissues. The purpose of this study was to explore the predictive value of Excel forms based on an automatic calculation in radical adaptive BT for cervical cancer. MATERIAL AND METHODS: A retrospective analysis of 119 patients suffering from cervical cancer, treated with radical radiotherapy. All patients were treated with EBRT and adaptive BT. EBRT prescribed dose was 42.0-50.4 Gy in 21-28 fractions. BT nominal prescribed dose was 28 Gy in 4 fractions, separated by one week. Total EQD(2) prediction at nth (n = 1-3) BT (TEPB(n)) or actual cumulative EQD(2) (ACEQD(2)) can be calculated automatically by inputting the physical dose based on an in-house designed application. The relationship between TEPB(n) and ACEQD(2) was evaluated, and the predictive value of Excel forms based on the automatic calculation was analyzed. RESULTS: For the volume of high-risk clinical target, there was a significant decrease between BT1 and BT2. Similarly, for the volume of intermediate-risk clinical target, there was a significant decrease between BT2 and BT3. The sensitivity ranges of TEPB(1), TEPB(2), and TEPB(3) prediction were 74.5-91.3%, 83.7-95.7%, and 92.9-99.1%, respectively, and the specificity ranges were 46.7-80.0%, 53.3-90.5%, and 66.7-90.5%, respectively. CONCLUSIONS: The in-house designed application has the function of quickly reading dose-volume histogram (DVH) parameters from the treatment planning system, which allows for balance between the total dose to target volumes and organs at risk (OARs). Excel forms based on EQD(2) automatic calculation presents high predictive accuracy. Termedia Publishing House 2020-10-30 2020-10 /pmc/articles/PMC7701924/ /pubmed/33299434 http://dx.doi.org/10.5114/jcb.2020.100378 Text en Copyright © 2020 Termedia http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY -NC -SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Original Paper
Cheng, Guanghui
Mu, Xin
Liu, Ying
Mao, Zhuang
Zhao, Hongfu
Predictive value of Excel forms based on an automatic calculation of dose equivalent in 2 Gy per fraction in adaptive brachytherapy for cervical cancer
title Predictive value of Excel forms based on an automatic calculation of dose equivalent in 2 Gy per fraction in adaptive brachytherapy for cervical cancer
title_full Predictive value of Excel forms based on an automatic calculation of dose equivalent in 2 Gy per fraction in adaptive brachytherapy for cervical cancer
title_fullStr Predictive value of Excel forms based on an automatic calculation of dose equivalent in 2 Gy per fraction in adaptive brachytherapy for cervical cancer
title_full_unstemmed Predictive value of Excel forms based on an automatic calculation of dose equivalent in 2 Gy per fraction in adaptive brachytherapy for cervical cancer
title_short Predictive value of Excel forms based on an automatic calculation of dose equivalent in 2 Gy per fraction in adaptive brachytherapy for cervical cancer
title_sort predictive value of excel forms based on an automatic calculation of dose equivalent in 2 gy per fraction in adaptive brachytherapy for cervical cancer
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7701924/
https://www.ncbi.nlm.nih.gov/pubmed/33299434
http://dx.doi.org/10.5114/jcb.2020.100378
work_keys_str_mv AT chengguanghui predictivevalueofexcelformsbasedonanautomaticcalculationofdoseequivalentin2gyperfractioninadaptivebrachytherapyforcervicalcancer
AT muxin predictivevalueofexcelformsbasedonanautomaticcalculationofdoseequivalentin2gyperfractioninadaptivebrachytherapyforcervicalcancer
AT liuying predictivevalueofexcelformsbasedonanautomaticcalculationofdoseequivalentin2gyperfractioninadaptivebrachytherapyforcervicalcancer
AT maozhuang predictivevalueofexcelformsbasedonanautomaticcalculationofdoseequivalentin2gyperfractioninadaptivebrachytherapyforcervicalcancer
AT zhaohongfu predictivevalueofexcelformsbasedonanautomaticcalculationofdoseequivalentin2gyperfractioninadaptivebrachytherapyforcervicalcancer