Cargando…

Improved physiological noise regression in fNIRS: A multimodal extension of the General Linear Model using temporally embedded Canonical Correlation Analysis

For the robust estimation of evoked brain activity from functional Near-Infrared Spectroscopy (fNIRS) signals, it is crucial to reduce nuisance signals from systemic physiology and motion. The current best practice incorporates short-separation (SS) fNIRS measurements as regressors in a General Line...

Descripción completa

Detalles Bibliográficos
Autores principales: von Lühmann, Alexander, Li, Xinge, Müller, Klaus-Robert, Boas, David A., Yücel, Meryem A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7703677/
https://www.ncbi.nlm.nih.gov/pubmed/31870944
http://dx.doi.org/10.1016/j.neuroimage.2019.116472
_version_ 1783616674710159360
author von Lühmann, Alexander
Li, Xinge
Müller, Klaus-Robert
Boas, David A.
Yücel, Meryem A.
author_facet von Lühmann, Alexander
Li, Xinge
Müller, Klaus-Robert
Boas, David A.
Yücel, Meryem A.
author_sort von Lühmann, Alexander
collection PubMed
description For the robust estimation of evoked brain activity from functional Near-Infrared Spectroscopy (fNIRS) signals, it is crucial to reduce nuisance signals from systemic physiology and motion. The current best practice incorporates short-separation (SS) fNIRS measurements as regressors in a General Linear Model (GLM). However, several challenging signal characteristics such as non-instantaneous and non-constant coupling are not yet addressed by this approach and additional auxiliary signals are not optimally exploited. We have recently introduced a new methodological framework for the unsupervised multivariate analysis of fNIRS signals using Blind Source Separation (BSS) methods. Building onto the framework, in this manuscript we show how to incorporate the advantages of regularized temporally embedded Canonical Correlation Analysis (tCCA) into the supervised GLM. This approach allows flexible integration of any number of auxiliary modalities and signals. We provide guidance for the selection of optimal parameters and auxiliary signals for the proposed GLM extension. Its performance in the recovery of evoked HRFs is then evaluated using both simulated ground truth data and real experimental data and compared with the GLM with short-separation regression. Our results show that the GLM with tCCA significantly improves upon the current best practice, yielding significantly better results across all applied metrics: Correlation (HbO max. +45%), Root Mean Squared Error (HbO max. −55%), F-Score (HbO up to 3.25-fold) and p-value as well as power spectral density of the noise floor. The proposed method can be incorporated into the GLM in an easily applicable way that flexibly combines any available auxiliary signals into optimal nuisance regressors. This work has potential significance both for conventional neuroscientific fNIRS experiments as well as for emerging applications of fNIRS in everyday environments, medicine and BCI, where high Contrast to Noise Ratio is of importance for single trial analysis.
format Online
Article
Text
id pubmed-7703677
institution National Center for Biotechnology Information
language English
publishDate 2019
record_format MEDLINE/PubMed
spelling pubmed-77036772020-11-30 Improved physiological noise regression in fNIRS: A multimodal extension of the General Linear Model using temporally embedded Canonical Correlation Analysis von Lühmann, Alexander Li, Xinge Müller, Klaus-Robert Boas, David A. Yücel, Meryem A. Neuroimage Article For the robust estimation of evoked brain activity from functional Near-Infrared Spectroscopy (fNIRS) signals, it is crucial to reduce nuisance signals from systemic physiology and motion. The current best practice incorporates short-separation (SS) fNIRS measurements as regressors in a General Linear Model (GLM). However, several challenging signal characteristics such as non-instantaneous and non-constant coupling are not yet addressed by this approach and additional auxiliary signals are not optimally exploited. We have recently introduced a new methodological framework for the unsupervised multivariate analysis of fNIRS signals using Blind Source Separation (BSS) methods. Building onto the framework, in this manuscript we show how to incorporate the advantages of regularized temporally embedded Canonical Correlation Analysis (tCCA) into the supervised GLM. This approach allows flexible integration of any number of auxiliary modalities and signals. We provide guidance for the selection of optimal parameters and auxiliary signals for the proposed GLM extension. Its performance in the recovery of evoked HRFs is then evaluated using both simulated ground truth data and real experimental data and compared with the GLM with short-separation regression. Our results show that the GLM with tCCA significantly improves upon the current best practice, yielding significantly better results across all applied metrics: Correlation (HbO max. +45%), Root Mean Squared Error (HbO max. −55%), F-Score (HbO up to 3.25-fold) and p-value as well as power spectral density of the noise floor. The proposed method can be incorporated into the GLM in an easily applicable way that flexibly combines any available auxiliary signals into optimal nuisance regressors. This work has potential significance both for conventional neuroscientific fNIRS experiments as well as for emerging applications of fNIRS in everyday environments, medicine and BCI, where high Contrast to Noise Ratio is of importance for single trial analysis. 2019-12-20 2020-03 /pmc/articles/PMC7703677/ /pubmed/31870944 http://dx.doi.org/10.1016/j.neuroimage.2019.116472 Text en This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
von Lühmann, Alexander
Li, Xinge
Müller, Klaus-Robert
Boas, David A.
Yücel, Meryem A.
Improved physiological noise regression in fNIRS: A multimodal extension of the General Linear Model using temporally embedded Canonical Correlation Analysis
title Improved physiological noise regression in fNIRS: A multimodal extension of the General Linear Model using temporally embedded Canonical Correlation Analysis
title_full Improved physiological noise regression in fNIRS: A multimodal extension of the General Linear Model using temporally embedded Canonical Correlation Analysis
title_fullStr Improved physiological noise regression in fNIRS: A multimodal extension of the General Linear Model using temporally embedded Canonical Correlation Analysis
title_full_unstemmed Improved physiological noise regression in fNIRS: A multimodal extension of the General Linear Model using temporally embedded Canonical Correlation Analysis
title_short Improved physiological noise regression in fNIRS: A multimodal extension of the General Linear Model using temporally embedded Canonical Correlation Analysis
title_sort improved physiological noise regression in fnirs: a multimodal extension of the general linear model using temporally embedded canonical correlation analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7703677/
https://www.ncbi.nlm.nih.gov/pubmed/31870944
http://dx.doi.org/10.1016/j.neuroimage.2019.116472
work_keys_str_mv AT vonluhmannalexander improvedphysiologicalnoiseregressioninfnirsamultimodalextensionofthegenerallinearmodelusingtemporallyembeddedcanonicalcorrelationanalysis
AT lixinge improvedphysiologicalnoiseregressioninfnirsamultimodalextensionofthegenerallinearmodelusingtemporallyembeddedcanonicalcorrelationanalysis
AT mullerklausrobert improvedphysiologicalnoiseregressioninfnirsamultimodalextensionofthegenerallinearmodelusingtemporallyembeddedcanonicalcorrelationanalysis
AT boasdavida improvedphysiologicalnoiseregressioninfnirsamultimodalextensionofthegenerallinearmodelusingtemporallyembeddedcanonicalcorrelationanalysis
AT yucelmeryema improvedphysiologicalnoiseregressioninfnirsamultimodalextensionofthegenerallinearmodelusingtemporallyembeddedcanonicalcorrelationanalysis