Cargando…

Controlling Bacterial Pathogens in Water for Reuse: Treatment Technologies for Water Recirculation in the Blue Diversion Autarky Toilet

The Blue Diversion AUTARKY Toilet is a urine-diverting toilet with on-site treatment. The toilet is being developed to provide a safe and affordable sanitation technology for people who lack access to sewer-based sanitation. Water used for personal hygiene, hand washing, and flushing to rinse urine-...

Descripción completa

Detalles Bibliográficos
Autores principales: Nguyen, Mi T., Allemann, Lukas, Ziemba, Christopher, Larive, Odile, Morgenroth, Eberhard, Julian, Timothy R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7705130/
https://www.ncbi.nlm.nih.gov/pubmed/33365315
http://dx.doi.org/10.3389/fenvs.2017.00090
_version_ 1783616901901975552
author Nguyen, Mi T.
Allemann, Lukas
Ziemba, Christopher
Larive, Odile
Morgenroth, Eberhard
Julian, Timothy R.
author_facet Nguyen, Mi T.
Allemann, Lukas
Ziemba, Christopher
Larive, Odile
Morgenroth, Eberhard
Julian, Timothy R.
author_sort Nguyen, Mi T.
collection PubMed
description The Blue Diversion AUTARKY Toilet is a urine-diverting toilet with on-site treatment. The toilet is being developed to provide a safe and affordable sanitation technology for people who lack access to sewer-based sanitation. Water used for personal hygiene, hand washing, and flushing to rinse urine- and feces-collection bowls is treated, stored, and recycled for reuse to reduce reliance on external water supplies. The system provides an opportunity to investigate hygiene of water for reuse following treatment. Treatment in the toilet includes a Biologically Activated Membrane Bioreactor (BAMBi) followed by a secondary treatment technology. To identify effective secondary treatment, three options, including granular activated carbon (GAC) only, GAC+chlorine (sodium hypochlorite), and GAC+electrolysis are considered based on the bacterial inactivation and growth inhibition efficiency. Four different hygiene-relevant bacteria are tested: Escherichia coli, Enterococcus faecalis, Pseudomonas aeruginosa, and Salmonella typhimurium. Our evaluation demonstrates that—despite treatment of water with the BAMBi—E. coli, P aeruginosa, and S. typhimurium have the potential to grow during storage in the absence of microbial competition. Including the indigenous microbial community influences bacterial growth in different ways: E. coli growth decreases but P. aeruginosa growth increases relative to no competition. The addition of the secondary treatment options considerably improves water quality. A column of GAC after the BAMBi reduces E. coli growth potential by 2 log(10), likely due to the reduction of carbon sources. Additional treatments including chlorination and electrolysis provide further safety margins, with more than 5 log-(10) inactivation of E. coli. However, reactivation and/or regrowth of E. coli and P. aeruginosa occurs under in the absence of residual disinfectant. Treatment including the BAMBi, GAC, and electrolysis appear to be promising technologies to control bacterial growth during storage in water intended for reuse.
format Online
Article
Text
id pubmed-7705130
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Frontiers
record_format MEDLINE/PubMed
spelling pubmed-77051302020-12-21 Controlling Bacterial Pathogens in Water for Reuse: Treatment Technologies for Water Recirculation in the Blue Diversion Autarky Toilet Nguyen, Mi T. Allemann, Lukas Ziemba, Christopher Larive, Odile Morgenroth, Eberhard Julian, Timothy R. Front Environ Sci Original Research The Blue Diversion AUTARKY Toilet is a urine-diverting toilet with on-site treatment. The toilet is being developed to provide a safe and affordable sanitation technology for people who lack access to sewer-based sanitation. Water used for personal hygiene, hand washing, and flushing to rinse urine- and feces-collection bowls is treated, stored, and recycled for reuse to reduce reliance on external water supplies. The system provides an opportunity to investigate hygiene of water for reuse following treatment. Treatment in the toilet includes a Biologically Activated Membrane Bioreactor (BAMBi) followed by a secondary treatment technology. To identify effective secondary treatment, three options, including granular activated carbon (GAC) only, GAC+chlorine (sodium hypochlorite), and GAC+electrolysis are considered based on the bacterial inactivation and growth inhibition efficiency. Four different hygiene-relevant bacteria are tested: Escherichia coli, Enterococcus faecalis, Pseudomonas aeruginosa, and Salmonella typhimurium. Our evaluation demonstrates that—despite treatment of water with the BAMBi—E. coli, P aeruginosa, and S. typhimurium have the potential to grow during storage in the absence of microbial competition. Including the indigenous microbial community influences bacterial growth in different ways: E. coli growth decreases but P. aeruginosa growth increases relative to no competition. The addition of the secondary treatment options considerably improves water quality. A column of GAC after the BAMBi reduces E. coli growth potential by 2 log(10), likely due to the reduction of carbon sources. Additional treatments including chlorination and electrolysis provide further safety margins, with more than 5 log-(10) inactivation of E. coli. However, reactivation and/or regrowth of E. coli and P. aeruginosa occurs under in the absence of residual disinfectant. Treatment including the BAMBi, GAC, and electrolysis appear to be promising technologies to control bacterial growth during storage in water intended for reuse. Frontiers 2017-12-19 /pmc/articles/PMC7705130/ /pubmed/33365315 http://dx.doi.org/10.3389/fenvs.2017.00090 Text en © 2017 Nguyen, Allemann, Ziemba, Larivé, Morgenroth and Julian http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Research
Nguyen, Mi T.
Allemann, Lukas
Ziemba, Christopher
Larive, Odile
Morgenroth, Eberhard
Julian, Timothy R.
Controlling Bacterial Pathogens in Water for Reuse: Treatment Technologies for Water Recirculation in the Blue Diversion Autarky Toilet
title Controlling Bacterial Pathogens in Water for Reuse: Treatment Technologies for Water Recirculation in the Blue Diversion Autarky Toilet
title_full Controlling Bacterial Pathogens in Water for Reuse: Treatment Technologies for Water Recirculation in the Blue Diversion Autarky Toilet
title_fullStr Controlling Bacterial Pathogens in Water for Reuse: Treatment Technologies for Water Recirculation in the Blue Diversion Autarky Toilet
title_full_unstemmed Controlling Bacterial Pathogens in Water for Reuse: Treatment Technologies for Water Recirculation in the Blue Diversion Autarky Toilet
title_short Controlling Bacterial Pathogens in Water for Reuse: Treatment Technologies for Water Recirculation in the Blue Diversion Autarky Toilet
title_sort controlling bacterial pathogens in water for reuse: treatment technologies for water recirculation in the blue diversion autarky toilet
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7705130/
https://www.ncbi.nlm.nih.gov/pubmed/33365315
http://dx.doi.org/10.3389/fenvs.2017.00090
work_keys_str_mv AT nguyenmit controllingbacterialpathogensinwaterforreusetreatmenttechnologiesforwaterrecirculationinthebluediversionautarkytoilet
AT allemannlukas controllingbacterialpathogensinwaterforreusetreatmenttechnologiesforwaterrecirculationinthebluediversionautarkytoilet
AT ziembachristopher controllingbacterialpathogensinwaterforreusetreatmenttechnologiesforwaterrecirculationinthebluediversionautarkytoilet
AT lariveodile controllingbacterialpathogensinwaterforreusetreatmenttechnologiesforwaterrecirculationinthebluediversionautarkytoilet
AT morgenrotheberhard controllingbacterialpathogensinwaterforreusetreatmenttechnologiesforwaterrecirculationinthebluediversionautarkytoilet
AT juliantimothyr controllingbacterialpathogensinwaterforreusetreatmenttechnologiesforwaterrecirculationinthebluediversionautarkytoilet