Cargando…

Evaluation of Deep Learning to Augment Image-Guided Radiotherapy for Head and Neck and Prostate Cancers

IMPORTANCE: Personalized radiotherapy planning depends on high-quality delineation of target tumors and surrounding organs at risk (OARs). This process puts additional time burdens on oncologists and introduces variability among both experts and institutions. OBJECTIVE: To explore clinically accepta...

Descripción completa

Detalles Bibliográficos
Autores principales: Oktay, Ozan, Nanavati, Jay, Schwaighofer, Anton, Carter, David, Bristow, Melissa, Tanno, Ryutaro, Jena, Rajesh, Barnett, Gill, Noble, David, Rimmer, Yvonne, Glocker, Ben, O’Hara, Kenton, Bishop, Christopher, Alvarez-Valle, Javier, Nori, Aditya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Medical Association 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7705593/
https://www.ncbi.nlm.nih.gov/pubmed/33252691
http://dx.doi.org/10.1001/jamanetworkopen.2020.27426
_version_ 1783616977535762432
author Oktay, Ozan
Nanavati, Jay
Schwaighofer, Anton
Carter, David
Bristow, Melissa
Tanno, Ryutaro
Jena, Rajesh
Barnett, Gill
Noble, David
Rimmer, Yvonne
Glocker, Ben
O’Hara, Kenton
Bishop, Christopher
Alvarez-Valle, Javier
Nori, Aditya
author_facet Oktay, Ozan
Nanavati, Jay
Schwaighofer, Anton
Carter, David
Bristow, Melissa
Tanno, Ryutaro
Jena, Rajesh
Barnett, Gill
Noble, David
Rimmer, Yvonne
Glocker, Ben
O’Hara, Kenton
Bishop, Christopher
Alvarez-Valle, Javier
Nori, Aditya
author_sort Oktay, Ozan
collection PubMed
description IMPORTANCE: Personalized radiotherapy planning depends on high-quality delineation of target tumors and surrounding organs at risk (OARs). This process puts additional time burdens on oncologists and introduces variability among both experts and institutions. OBJECTIVE: To explore clinically acceptable autocontouring solutions that can be integrated into existing workflows and used in different domains of radiotherapy. DESIGN, SETTING, AND PARTICIPANTS: This quality improvement study used a multicenter imaging data set comprising 519 pelvic and 242 head and neck computed tomography (CT) scans from 8 distinct clinical sites and patients diagnosed either with prostate or head and neck cancer. The scans were acquired as part of treatment dose planning from patients who received intensity-modulated radiation therapy between October 2013 and February 2020. Fifteen different OARs were manually annotated by expert readers and radiation oncologists. The models were trained on a subset of the data set to automatically delineate OARs and evaluated on both internal and external data sets. Data analysis was conducted October 2019 to September 2020. MAIN OUTCOMES AND MEASURES: The autocontouring solution was evaluated on external data sets, and its accuracy was quantified with volumetric agreement and surface distance measures. Models were benchmarked against expert annotations in an interobserver variability (IOV) study. Clinical utility was evaluated by measuring time spent on manual corrections and annotations from scratch. RESULTS: A total of 519 participants’ (519 [100%] men; 390 [75%] aged 62-75 years) pelvic CT images and 242 participants’ (184 [76%] men; 194 [80%] aged 50-73 years) head and neck CT images were included. The models achieved levels of clinical accuracy within the bounds of expert IOV for 13 of 15 structures (eg, left femur, κ = 0.982; brainstem, κ = 0.806) and performed consistently well across both external and internal data sets (eg, mean [SD] Dice score for left femur, internal vs external data sets: 98.52% [0.50] vs 98.04% [1.02]; P = .04). The correction time of autogenerated contours on 10 head and neck and 10 prostate scans was measured as a mean of 4.98 (95% CI, 4.44-5.52) min/scan and 3.40 (95% CI, 1.60-5.20) min/scan, respectively, to ensure clinically accepted accuracy, whereas contouring from scratch on the same scans was observed to be 73.25 (95% CI, 68.68-77.82) min/scan and 86.75 (95% CI, 75.21-92.29) min/scan, respectively, accounting for a 93% reduction in time. CONCLUSIONS AND RELEVANCE: In this study, the models achieved levels of clinical accuracy within expert IOV while reducing manual contouring time and performing consistently well across previously unseen heterogeneous data sets. With the availability of open-source libraries and reliable performance, this creates significant opportunities for the transformation of radiation treatment planning.
format Online
Article
Text
id pubmed-7705593
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher American Medical Association
record_format MEDLINE/PubMed
spelling pubmed-77055932020-12-09 Evaluation of Deep Learning to Augment Image-Guided Radiotherapy for Head and Neck and Prostate Cancers Oktay, Ozan Nanavati, Jay Schwaighofer, Anton Carter, David Bristow, Melissa Tanno, Ryutaro Jena, Rajesh Barnett, Gill Noble, David Rimmer, Yvonne Glocker, Ben O’Hara, Kenton Bishop, Christopher Alvarez-Valle, Javier Nori, Aditya JAMA Netw Open Original Investigation IMPORTANCE: Personalized radiotherapy planning depends on high-quality delineation of target tumors and surrounding organs at risk (OARs). This process puts additional time burdens on oncologists and introduces variability among both experts and institutions. OBJECTIVE: To explore clinically acceptable autocontouring solutions that can be integrated into existing workflows and used in different domains of radiotherapy. DESIGN, SETTING, AND PARTICIPANTS: This quality improvement study used a multicenter imaging data set comprising 519 pelvic and 242 head and neck computed tomography (CT) scans from 8 distinct clinical sites and patients diagnosed either with prostate or head and neck cancer. The scans were acquired as part of treatment dose planning from patients who received intensity-modulated radiation therapy between October 2013 and February 2020. Fifteen different OARs were manually annotated by expert readers and radiation oncologists. The models were trained on a subset of the data set to automatically delineate OARs and evaluated on both internal and external data sets. Data analysis was conducted October 2019 to September 2020. MAIN OUTCOMES AND MEASURES: The autocontouring solution was evaluated on external data sets, and its accuracy was quantified with volumetric agreement and surface distance measures. Models were benchmarked against expert annotations in an interobserver variability (IOV) study. Clinical utility was evaluated by measuring time spent on manual corrections and annotations from scratch. RESULTS: A total of 519 participants’ (519 [100%] men; 390 [75%] aged 62-75 years) pelvic CT images and 242 participants’ (184 [76%] men; 194 [80%] aged 50-73 years) head and neck CT images were included. The models achieved levels of clinical accuracy within the bounds of expert IOV for 13 of 15 structures (eg, left femur, κ = 0.982; brainstem, κ = 0.806) and performed consistently well across both external and internal data sets (eg, mean [SD] Dice score for left femur, internal vs external data sets: 98.52% [0.50] vs 98.04% [1.02]; P = .04). The correction time of autogenerated contours on 10 head and neck and 10 prostate scans was measured as a mean of 4.98 (95% CI, 4.44-5.52) min/scan and 3.40 (95% CI, 1.60-5.20) min/scan, respectively, to ensure clinically accepted accuracy, whereas contouring from scratch on the same scans was observed to be 73.25 (95% CI, 68.68-77.82) min/scan and 86.75 (95% CI, 75.21-92.29) min/scan, respectively, accounting for a 93% reduction in time. CONCLUSIONS AND RELEVANCE: In this study, the models achieved levels of clinical accuracy within expert IOV while reducing manual contouring time and performing consistently well across previously unseen heterogeneous data sets. With the availability of open-source libraries and reliable performance, this creates significant opportunities for the transformation of radiation treatment planning. American Medical Association 2020-11-30 /pmc/articles/PMC7705593/ /pubmed/33252691 http://dx.doi.org/10.1001/jamanetworkopen.2020.27426 Text en Copyright 2020 Oktay O et al. JAMA Network Open. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the CC-BY-NC-ND License.
spellingShingle Original Investigation
Oktay, Ozan
Nanavati, Jay
Schwaighofer, Anton
Carter, David
Bristow, Melissa
Tanno, Ryutaro
Jena, Rajesh
Barnett, Gill
Noble, David
Rimmer, Yvonne
Glocker, Ben
O’Hara, Kenton
Bishop, Christopher
Alvarez-Valle, Javier
Nori, Aditya
Evaluation of Deep Learning to Augment Image-Guided Radiotherapy for Head and Neck and Prostate Cancers
title Evaluation of Deep Learning to Augment Image-Guided Radiotherapy for Head and Neck and Prostate Cancers
title_full Evaluation of Deep Learning to Augment Image-Guided Radiotherapy for Head and Neck and Prostate Cancers
title_fullStr Evaluation of Deep Learning to Augment Image-Guided Radiotherapy for Head and Neck and Prostate Cancers
title_full_unstemmed Evaluation of Deep Learning to Augment Image-Guided Radiotherapy for Head and Neck and Prostate Cancers
title_short Evaluation of Deep Learning to Augment Image-Guided Radiotherapy for Head and Neck and Prostate Cancers
title_sort evaluation of deep learning to augment image-guided radiotherapy for head and neck and prostate cancers
topic Original Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7705593/
https://www.ncbi.nlm.nih.gov/pubmed/33252691
http://dx.doi.org/10.1001/jamanetworkopen.2020.27426
work_keys_str_mv AT oktayozan evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT nanavatijay evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT schwaighoferanton evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT carterdavid evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT bristowmelissa evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT tannoryutaro evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT jenarajesh evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT barnettgill evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT nobledavid evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT rimmeryvonne evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT glockerben evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT oharakenton evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT bishopchristopher evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT alvarezvallejavier evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers
AT noriaditya evaluationofdeeplearningtoaugmentimageguidedradiotherapyforheadandneckandprostatecancers