Cargando…

A systematic scoping review to identify the design and assess the performance of devices for antenatal continuous fetal monitoring

BACKGROUND: Antepartum fetal monitoring aims to assess fetal development and wellbeing throughout pregnancy. Current methods utilised in clinical practice are intermittent and only provide a ‘snapshot’ of fetal wellbeing, thus key signs of fetal demise could be missed. Continuous fetal monitoring (C...

Descripción completa

Detalles Bibliográficos
Autores principales: Tamber, Kajal K., Hayes, Dexter J. L., Carey, Stephen J., Wijekoon, Jayawan H. B., Heazell, Alexander E. P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7707469/
https://www.ncbi.nlm.nih.gov/pubmed/33259507
http://dx.doi.org/10.1371/journal.pone.0242983
_version_ 1783617354741055488
author Tamber, Kajal K.
Hayes, Dexter J. L.
Carey, Stephen J.
Wijekoon, Jayawan H. B.
Heazell, Alexander E. P.
author_facet Tamber, Kajal K.
Hayes, Dexter J. L.
Carey, Stephen J.
Wijekoon, Jayawan H. B.
Heazell, Alexander E. P.
author_sort Tamber, Kajal K.
collection PubMed
description BACKGROUND: Antepartum fetal monitoring aims to assess fetal development and wellbeing throughout pregnancy. Current methods utilised in clinical practice are intermittent and only provide a ‘snapshot’ of fetal wellbeing, thus key signs of fetal demise could be missed. Continuous fetal monitoring (CFM) offers the potential to alleviate these issues by providing an objective and longitudinal overview of fetal status. Various CFM devices exist within literature; this review planned to provide a systematic overview of these devices, and specifically aimed to map the devices’ design, performance and factors which affect this, whilst determining any gaps in development. METHODS: A systematic search was conducted using MEDLINE, EMBASE, CINAHL, EMCARE, BNI, Cochrane Library, Web of Science and Pubmed databases. Following the deletion of duplicates, the articles’ titles and abstracts were screened and suitable papers underwent a full-text assessment prior to inclusion in the review by two independent assessors. RESULTS: The literature searches generated 4,885 hits from which 43 studies were included in the review. Twenty-four different devices were identified utilising four suitable CFM technologies: fetal electrocardiography, fetal phonocardiography, accelerometry and fetal vectorcardiography. The devices adopted various designs and signal processing methods. There was no common means of device performance assessment between different devices, which limited comparison. The device performance of fetal electrocardiography was reduced between 28 to 36 weeks’ gestation and during high levels of maternal movement, and increased during night-time rest. Other factors, including maternal body mass index, fetal position, recording location, uterine activity, amniotic fluid index, number of fetuses and smoking status, as well as factors which affected alternative technologies had equivocal effects and require further investigation. CONCLUSIONS: A variety of CFM devices have been developed, however no specific approach or design appears to be advantageous due to high levels of inter-device and intra-device variability.
format Online
Article
Text
id pubmed-7707469
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-77074692020-12-08 A systematic scoping review to identify the design and assess the performance of devices for antenatal continuous fetal monitoring Tamber, Kajal K. Hayes, Dexter J. L. Carey, Stephen J. Wijekoon, Jayawan H. B. Heazell, Alexander E. P. PLoS One Research Article BACKGROUND: Antepartum fetal monitoring aims to assess fetal development and wellbeing throughout pregnancy. Current methods utilised in clinical practice are intermittent and only provide a ‘snapshot’ of fetal wellbeing, thus key signs of fetal demise could be missed. Continuous fetal monitoring (CFM) offers the potential to alleviate these issues by providing an objective and longitudinal overview of fetal status. Various CFM devices exist within literature; this review planned to provide a systematic overview of these devices, and specifically aimed to map the devices’ design, performance and factors which affect this, whilst determining any gaps in development. METHODS: A systematic search was conducted using MEDLINE, EMBASE, CINAHL, EMCARE, BNI, Cochrane Library, Web of Science and Pubmed databases. Following the deletion of duplicates, the articles’ titles and abstracts were screened and suitable papers underwent a full-text assessment prior to inclusion in the review by two independent assessors. RESULTS: The literature searches generated 4,885 hits from which 43 studies were included in the review. Twenty-four different devices were identified utilising four suitable CFM technologies: fetal electrocardiography, fetal phonocardiography, accelerometry and fetal vectorcardiography. The devices adopted various designs and signal processing methods. There was no common means of device performance assessment between different devices, which limited comparison. The device performance of fetal electrocardiography was reduced between 28 to 36 weeks’ gestation and during high levels of maternal movement, and increased during night-time rest. Other factors, including maternal body mass index, fetal position, recording location, uterine activity, amniotic fluid index, number of fetuses and smoking status, as well as factors which affected alternative technologies had equivocal effects and require further investigation. CONCLUSIONS: A variety of CFM devices have been developed, however no specific approach or design appears to be advantageous due to high levels of inter-device and intra-device variability. Public Library of Science 2020-12-01 /pmc/articles/PMC7707469/ /pubmed/33259507 http://dx.doi.org/10.1371/journal.pone.0242983 Text en © 2020 Tamber et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Tamber, Kajal K.
Hayes, Dexter J. L.
Carey, Stephen J.
Wijekoon, Jayawan H. B.
Heazell, Alexander E. P.
A systematic scoping review to identify the design and assess the performance of devices for antenatal continuous fetal monitoring
title A systematic scoping review to identify the design and assess the performance of devices for antenatal continuous fetal monitoring
title_full A systematic scoping review to identify the design and assess the performance of devices for antenatal continuous fetal monitoring
title_fullStr A systematic scoping review to identify the design and assess the performance of devices for antenatal continuous fetal monitoring
title_full_unstemmed A systematic scoping review to identify the design and assess the performance of devices for antenatal continuous fetal monitoring
title_short A systematic scoping review to identify the design and assess the performance of devices for antenatal continuous fetal monitoring
title_sort systematic scoping review to identify the design and assess the performance of devices for antenatal continuous fetal monitoring
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7707469/
https://www.ncbi.nlm.nih.gov/pubmed/33259507
http://dx.doi.org/10.1371/journal.pone.0242983
work_keys_str_mv AT tamberkajalk asystematicscopingreviewtoidentifythedesignandassesstheperformanceofdevicesforantenatalcontinuousfetalmonitoring
AT hayesdexterjl asystematicscopingreviewtoidentifythedesignandassesstheperformanceofdevicesforantenatalcontinuousfetalmonitoring
AT careystephenj asystematicscopingreviewtoidentifythedesignandassesstheperformanceofdevicesforantenatalcontinuousfetalmonitoring
AT wijekoonjayawanhb asystematicscopingreviewtoidentifythedesignandassesstheperformanceofdevicesforantenatalcontinuousfetalmonitoring
AT heazellalexanderep asystematicscopingreviewtoidentifythedesignandassesstheperformanceofdevicesforantenatalcontinuousfetalmonitoring
AT tamberkajalk systematicscopingreviewtoidentifythedesignandassesstheperformanceofdevicesforantenatalcontinuousfetalmonitoring
AT hayesdexterjl systematicscopingreviewtoidentifythedesignandassesstheperformanceofdevicesforantenatalcontinuousfetalmonitoring
AT careystephenj systematicscopingreviewtoidentifythedesignandassesstheperformanceofdevicesforantenatalcontinuousfetalmonitoring
AT wijekoonjayawanhb systematicscopingreviewtoidentifythedesignandassesstheperformanceofdevicesforantenatalcontinuousfetalmonitoring
AT heazellalexanderep systematicscopingreviewtoidentifythedesignandassesstheperformanceofdevicesforantenatalcontinuousfetalmonitoring