Cargando…
Wear of feldspathic-ceramic-veneered zirconia posterior FPDs after 10 years
BACKGROUND: The abrasion behavior of various ceramics is rarely investigated, though it is relevant for the clinical success of such restorations. The aim of this in vivo study was to evaluate the wear of feldspathic-ceramic-veneered zirconium oxide frameworks over a period of at least 10 years. MET...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7708209/ https://www.ncbi.nlm.nih.gov/pubmed/33256686 http://dx.doi.org/10.1186/s12903-020-01336-8 |
_version_ | 1783617517252509696 |
---|---|
author | Matta, Ragai-Edward Motel, Constantin Kirchner, Elena Stelzer, Simon Paul Adler, Werner Wichmann, Manfred Berger, Lara |
author_facet | Matta, Ragai-Edward Motel, Constantin Kirchner, Elena Stelzer, Simon Paul Adler, Werner Wichmann, Manfred Berger, Lara |
author_sort | Matta, Ragai-Edward |
collection | PubMed |
description | BACKGROUND: The abrasion behavior of various ceramics is rarely investigated, though it is relevant for the clinical success of such restorations. The aim of this in vivo study was to evaluate the wear of feldspathic-ceramic-veneered zirconium oxide frameworks over a period of at least 10 years. METHODS: The abrasion behavior of 15 bridge constructions from 15 different participants was examined after a period of 3, 5, and 10 years using plaster models, which were then subjected to a scanning process on the Atos II industrial scanner and digitized for three-dimensional evaluation of the abrasion by the corresponding software (ATOS Professional 7.6). The individual post-examination models were compared to the baseline model and deviations calculated in the sense of the largest, punctual loss of material in millimeters (“minimal distance”), the average abrasion in millimeters (“mean distance”), and the volume decrease in cubic millimeters (“integrated distance”). Statistical analyses were performed using the Wilcoxon sign rank test or mixed regression models. Multiple testing was considered by Benjamini-Hochberg correction. The significance level was set at 0.05. RESULTS: We found steadily increasing wear of the ceramic. The average volume decrease was significant (P < 0.001) at 3 years and 10 years (− 3.25 mm(3) and − 8.11 mm(3), respectively). CONCLUSIONS: The results of this study indicate that the rate of volume loss in feldspathic-ceramic-veneered zirconia frameworks in the posterior region increases significantly over time. An increasing frequency of parameters was observed, particularly in the second half of the study period. However, the use of this class of materials can be considered clinically acceptable. Trial registration This study is registered in DRKS - German Clinical Trials Register with the register number DRKS00021743. https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00021743 |
format | Online Article Text |
id | pubmed-7708209 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-77082092020-12-02 Wear of feldspathic-ceramic-veneered zirconia posterior FPDs after 10 years Matta, Ragai-Edward Motel, Constantin Kirchner, Elena Stelzer, Simon Paul Adler, Werner Wichmann, Manfred Berger, Lara BMC Oral Health Research Article BACKGROUND: The abrasion behavior of various ceramics is rarely investigated, though it is relevant for the clinical success of such restorations. The aim of this in vivo study was to evaluate the wear of feldspathic-ceramic-veneered zirconium oxide frameworks over a period of at least 10 years. METHODS: The abrasion behavior of 15 bridge constructions from 15 different participants was examined after a period of 3, 5, and 10 years using plaster models, which were then subjected to a scanning process on the Atos II industrial scanner and digitized for three-dimensional evaluation of the abrasion by the corresponding software (ATOS Professional 7.6). The individual post-examination models were compared to the baseline model and deviations calculated in the sense of the largest, punctual loss of material in millimeters (“minimal distance”), the average abrasion in millimeters (“mean distance”), and the volume decrease in cubic millimeters (“integrated distance”). Statistical analyses were performed using the Wilcoxon sign rank test or mixed regression models. Multiple testing was considered by Benjamini-Hochberg correction. The significance level was set at 0.05. RESULTS: We found steadily increasing wear of the ceramic. The average volume decrease was significant (P < 0.001) at 3 years and 10 years (− 3.25 mm(3) and − 8.11 mm(3), respectively). CONCLUSIONS: The results of this study indicate that the rate of volume loss in feldspathic-ceramic-veneered zirconia frameworks in the posterior region increases significantly over time. An increasing frequency of parameters was observed, particularly in the second half of the study period. However, the use of this class of materials can be considered clinically acceptable. Trial registration This study is registered in DRKS - German Clinical Trials Register with the register number DRKS00021743. https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00021743 BioMed Central 2020-11-30 /pmc/articles/PMC7708209/ /pubmed/33256686 http://dx.doi.org/10.1186/s12903-020-01336-8 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Matta, Ragai-Edward Motel, Constantin Kirchner, Elena Stelzer, Simon Paul Adler, Werner Wichmann, Manfred Berger, Lara Wear of feldspathic-ceramic-veneered zirconia posterior FPDs after 10 years |
title | Wear of feldspathic-ceramic-veneered zirconia posterior FPDs after 10 years |
title_full | Wear of feldspathic-ceramic-veneered zirconia posterior FPDs after 10 years |
title_fullStr | Wear of feldspathic-ceramic-veneered zirconia posterior FPDs after 10 years |
title_full_unstemmed | Wear of feldspathic-ceramic-veneered zirconia posterior FPDs after 10 years |
title_short | Wear of feldspathic-ceramic-veneered zirconia posterior FPDs after 10 years |
title_sort | wear of feldspathic-ceramic-veneered zirconia posterior fpds after 10 years |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7708209/ https://www.ncbi.nlm.nih.gov/pubmed/33256686 http://dx.doi.org/10.1186/s12903-020-01336-8 |
work_keys_str_mv | AT mattaragaiedward wearoffeldspathicceramicveneeredzirconiaposteriorfpdsafter10years AT motelconstantin wearoffeldspathicceramicveneeredzirconiaposteriorfpdsafter10years AT kirchnerelena wearoffeldspathicceramicveneeredzirconiaposteriorfpdsafter10years AT stelzersimonpaul wearoffeldspathicceramicveneeredzirconiaposteriorfpdsafter10years AT adlerwerner wearoffeldspathicceramicveneeredzirconiaposteriorfpdsafter10years AT wichmannmanfred wearoffeldspathicceramicveneeredzirconiaposteriorfpdsafter10years AT bergerlara wearoffeldspathicceramicveneeredzirconiaposteriorfpdsafter10years |