Cargando…
Developmental Validation of a MPS Workflow with a PCR-Based Short Amplicon Whole Mitochondrial Genome Panel
For the adoption of massively parallel sequencing (MPS) systems by forensic laboratories, validation studies on specific workflows are needed to support the feasibility of implementation and the reliability of the data they produce. As such, the whole mitochondrial genome sequencing methodology—Prec...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7709034/ https://www.ncbi.nlm.nih.gov/pubmed/33202822 http://dx.doi.org/10.3390/genes11111345 |
_version_ | 1783617665720385536 |
---|---|
author | Cihlar, Jennifer Churchill Amory, Christina Lagacé, Robert Roth, Chantal Parson, Walther Budowle, Bruce |
author_facet | Cihlar, Jennifer Churchill Amory, Christina Lagacé, Robert Roth, Chantal Parson, Walther Budowle, Bruce |
author_sort | Cihlar, Jennifer Churchill |
collection | PubMed |
description | For the adoption of massively parallel sequencing (MPS) systems by forensic laboratories, validation studies on specific workflows are needed to support the feasibility of implementation and the reliability of the data they produce. As such, the whole mitochondrial genome sequencing methodology—Precision ID mtDNA Whole Genome Panel, Ion Chef, Ion S5, and Converge—has been subjected to a variety of developmental validation studies. These validation studies were completed in accordance with the Scientific Working Group on DNA Analysis Methods (SWGDAM) validation guidelines and assessed reproducibility, repeatability, accuracy, sensitivity, specificity to human DNA, and ability to analyze challenging (e.g., mixed, degraded, or low quantity) samples. Intra- and inter-run replicates produced an average maximum pairwise difference in variant frequency of 1.2%. Concordance with data generated with traditional Sanger sequencing and an orthogonal MPS platform methodology was used to assess accuracy, and generation of complete and concordant haplotypes at DNA input levels as low as 37.5 pg of nuclear DNA or 187.5 mitochondrial genome copies illustrated the sensitivity of the system. Overall, data presented herein demonstrate that highly accurate and reproducible results were generated for a variety of sample qualities and quantities, supporting the reliability of this specific whole genome mitochondrial DNA MPS system for analysis of forensic biological evidence. |
format | Online Article Text |
id | pubmed-7709034 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77090342020-12-03 Developmental Validation of a MPS Workflow with a PCR-Based Short Amplicon Whole Mitochondrial Genome Panel Cihlar, Jennifer Churchill Amory, Christina Lagacé, Robert Roth, Chantal Parson, Walther Budowle, Bruce Genes (Basel) Article For the adoption of massively parallel sequencing (MPS) systems by forensic laboratories, validation studies on specific workflows are needed to support the feasibility of implementation and the reliability of the data they produce. As such, the whole mitochondrial genome sequencing methodology—Precision ID mtDNA Whole Genome Panel, Ion Chef, Ion S5, and Converge—has been subjected to a variety of developmental validation studies. These validation studies were completed in accordance with the Scientific Working Group on DNA Analysis Methods (SWGDAM) validation guidelines and assessed reproducibility, repeatability, accuracy, sensitivity, specificity to human DNA, and ability to analyze challenging (e.g., mixed, degraded, or low quantity) samples. Intra- and inter-run replicates produced an average maximum pairwise difference in variant frequency of 1.2%. Concordance with data generated with traditional Sanger sequencing and an orthogonal MPS platform methodology was used to assess accuracy, and generation of complete and concordant haplotypes at DNA input levels as low as 37.5 pg of nuclear DNA or 187.5 mitochondrial genome copies illustrated the sensitivity of the system. Overall, data presented herein demonstrate that highly accurate and reproducible results were generated for a variety of sample qualities and quantities, supporting the reliability of this specific whole genome mitochondrial DNA MPS system for analysis of forensic biological evidence. MDPI 2020-11-13 /pmc/articles/PMC7709034/ /pubmed/33202822 http://dx.doi.org/10.3390/genes11111345 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Cihlar, Jennifer Churchill Amory, Christina Lagacé, Robert Roth, Chantal Parson, Walther Budowle, Bruce Developmental Validation of a MPS Workflow with a PCR-Based Short Amplicon Whole Mitochondrial Genome Panel |
title | Developmental Validation of a MPS Workflow with a PCR-Based Short Amplicon Whole Mitochondrial Genome Panel |
title_full | Developmental Validation of a MPS Workflow with a PCR-Based Short Amplicon Whole Mitochondrial Genome Panel |
title_fullStr | Developmental Validation of a MPS Workflow with a PCR-Based Short Amplicon Whole Mitochondrial Genome Panel |
title_full_unstemmed | Developmental Validation of a MPS Workflow with a PCR-Based Short Amplicon Whole Mitochondrial Genome Panel |
title_short | Developmental Validation of a MPS Workflow with a PCR-Based Short Amplicon Whole Mitochondrial Genome Panel |
title_sort | developmental validation of a mps workflow with a pcr-based short amplicon whole mitochondrial genome panel |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7709034/ https://www.ncbi.nlm.nih.gov/pubmed/33202822 http://dx.doi.org/10.3390/genes11111345 |
work_keys_str_mv | AT cihlarjenniferchurchill developmentalvalidationofampsworkflowwithapcrbasedshortampliconwholemitochondrialgenomepanel AT amorychristina developmentalvalidationofampsworkflowwithapcrbasedshortampliconwholemitochondrialgenomepanel AT lagacerobert developmentalvalidationofampsworkflowwithapcrbasedshortampliconwholemitochondrialgenomepanel AT rothchantal developmentalvalidationofampsworkflowwithapcrbasedshortampliconwholemitochondrialgenomepanel AT parsonwalther developmentalvalidationofampsworkflowwithapcrbasedshortampliconwholemitochondrialgenomepanel AT budowlebruce developmentalvalidationofampsworkflowwithapcrbasedshortampliconwholemitochondrialgenomepanel |