Cargando…
An Experimental Intervention Study Assessing the Impact of a Thin Silicone Gel Surface Overlay on Interface Pressure
INTRODUCTION: The incidence of pressure ulcers (PUs) presents a substantial threat to patients, especially geriatric patients, those with restricted mobility, and patients suffering from chronic diseases such as cancer. PUs creates a huge financial burden on healthcare authorities and patients, cost...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7710438/ https://www.ncbi.nlm.nih.gov/pubmed/33299607 http://dx.doi.org/10.1155/2020/3246531 |
_version_ | 1783617946572029952 |
---|---|
author | Angmorterh, Seth Kwadjo England, Andrew Aboagye, Sonia Ofori, Eric Kwasi Hogg, Peter |
author_facet | Angmorterh, Seth Kwadjo England, Andrew Aboagye, Sonia Ofori, Eric Kwasi Hogg, Peter |
author_sort | Angmorterh, Seth Kwadjo |
collection | PubMed |
description | INTRODUCTION: The incidence of pressure ulcers (PUs) presents a substantial threat to patients, especially geriatric patients, those with restricted mobility, and patients suffering from chronic diseases such as cancer. PUs creates a huge financial burden on healthcare authorities and patients, costing billions to treat and manage. Radiography and radiotherapy patients may experience medical device related (MDR) PUs and studies have shown that high interface pressure (IP) values exist for the head when placed on an X-ray table without a mattress. These high IP values pose a PU risk to patients, especially those accessing prolonged radiography/radiology and radiotherapy procedures. The current study assessed the impact on IP values for the head from using a thin silicone gel surface overlay during radiographic procedures and identified whether this reduced the risk of PUs. MATERIALS AND METHODS: A calibrated XSENSOR pressure mat was used to measure IP for the head on an X-ray table with and without a thin silicone gel surface overlay. Prior to pressure mapping, the silicone gel surface overlay was assessed for its impact on radiation attenuation and image quality. RESULTS: Study participants were 14 males (70%) and six females (30%), with an age range of 25–53 years (mean = 34.4 ± 7.0). Paired-samples t-test results indicated that there was a statistically significant decrease in the mean IP for the head on the X-ray table without the silicone gel surface overlay (mean = 83.9 ± 8.2 in mmHg) and the X-ray table with the gel surface overlay (mean = 62.4 ± 6.1 in mmHg), p ≤ 0.001. Paired-samples t-test results indicated that there was a statistically significant decrease in the mean peak pressure index (PPI) for the head on the X-ray table without the silicone gel surface overlay (mean = 205.1 ± 28.2 in mmHg) and the X-ray table with the gel surface overlay (mean = 159.8 ± 26.8 in mmHg), p ≤ 0.001. CONCLUSIONS: The use of a thin silicone gel surface overlay could reduce IP risk for the head by approximately 25%. The reduction in IP risk could have a significant impact in reducing the risk of developing a PU. To ensure maximum benefit, the silicone gel surface overlay should be evaluated to address the specific needs within radiography and radiotherapy planning and treatment settings. |
format | Online Article Text |
id | pubmed-7710438 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-77104382020-12-08 An Experimental Intervention Study Assessing the Impact of a Thin Silicone Gel Surface Overlay on Interface Pressure Angmorterh, Seth Kwadjo England, Andrew Aboagye, Sonia Ofori, Eric Kwasi Hogg, Peter Radiol Res Pract Research Article INTRODUCTION: The incidence of pressure ulcers (PUs) presents a substantial threat to patients, especially geriatric patients, those with restricted mobility, and patients suffering from chronic diseases such as cancer. PUs creates a huge financial burden on healthcare authorities and patients, costing billions to treat and manage. Radiography and radiotherapy patients may experience medical device related (MDR) PUs and studies have shown that high interface pressure (IP) values exist for the head when placed on an X-ray table without a mattress. These high IP values pose a PU risk to patients, especially those accessing prolonged radiography/radiology and radiotherapy procedures. The current study assessed the impact on IP values for the head from using a thin silicone gel surface overlay during radiographic procedures and identified whether this reduced the risk of PUs. MATERIALS AND METHODS: A calibrated XSENSOR pressure mat was used to measure IP for the head on an X-ray table with and without a thin silicone gel surface overlay. Prior to pressure mapping, the silicone gel surface overlay was assessed for its impact on radiation attenuation and image quality. RESULTS: Study participants were 14 males (70%) and six females (30%), with an age range of 25–53 years (mean = 34.4 ± 7.0). Paired-samples t-test results indicated that there was a statistically significant decrease in the mean IP for the head on the X-ray table without the silicone gel surface overlay (mean = 83.9 ± 8.2 in mmHg) and the X-ray table with the gel surface overlay (mean = 62.4 ± 6.1 in mmHg), p ≤ 0.001. Paired-samples t-test results indicated that there was a statistically significant decrease in the mean peak pressure index (PPI) for the head on the X-ray table without the silicone gel surface overlay (mean = 205.1 ± 28.2 in mmHg) and the X-ray table with the gel surface overlay (mean = 159.8 ± 26.8 in mmHg), p ≤ 0.001. CONCLUSIONS: The use of a thin silicone gel surface overlay could reduce IP risk for the head by approximately 25%. The reduction in IP risk could have a significant impact in reducing the risk of developing a PU. To ensure maximum benefit, the silicone gel surface overlay should be evaluated to address the specific needs within radiography and radiotherapy planning and treatment settings. Hindawi 2020-11-24 /pmc/articles/PMC7710438/ /pubmed/33299607 http://dx.doi.org/10.1155/2020/3246531 Text en Copyright © 2020 Seth Kwadjo Angmorterh et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Angmorterh, Seth Kwadjo England, Andrew Aboagye, Sonia Ofori, Eric Kwasi Hogg, Peter An Experimental Intervention Study Assessing the Impact of a Thin Silicone Gel Surface Overlay on Interface Pressure |
title | An Experimental Intervention Study Assessing the Impact of a Thin Silicone Gel Surface Overlay on Interface Pressure |
title_full | An Experimental Intervention Study Assessing the Impact of a Thin Silicone Gel Surface Overlay on Interface Pressure |
title_fullStr | An Experimental Intervention Study Assessing the Impact of a Thin Silicone Gel Surface Overlay on Interface Pressure |
title_full_unstemmed | An Experimental Intervention Study Assessing the Impact of a Thin Silicone Gel Surface Overlay on Interface Pressure |
title_short | An Experimental Intervention Study Assessing the Impact of a Thin Silicone Gel Surface Overlay on Interface Pressure |
title_sort | experimental intervention study assessing the impact of a thin silicone gel surface overlay on interface pressure |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7710438/ https://www.ncbi.nlm.nih.gov/pubmed/33299607 http://dx.doi.org/10.1155/2020/3246531 |
work_keys_str_mv | AT angmorterhsethkwadjo anexperimentalinterventionstudyassessingtheimpactofathinsiliconegelsurfaceoverlayoninterfacepressure AT englandandrew anexperimentalinterventionstudyassessingtheimpactofathinsiliconegelsurfaceoverlayoninterfacepressure AT aboagyesonia anexperimentalinterventionstudyassessingtheimpactofathinsiliconegelsurfaceoverlayoninterfacepressure AT oforierickwasi anexperimentalinterventionstudyassessingtheimpactofathinsiliconegelsurfaceoverlayoninterfacepressure AT hoggpeter anexperimentalinterventionstudyassessingtheimpactofathinsiliconegelsurfaceoverlayoninterfacepressure AT angmorterhsethkwadjo experimentalinterventionstudyassessingtheimpactofathinsiliconegelsurfaceoverlayoninterfacepressure AT englandandrew experimentalinterventionstudyassessingtheimpactofathinsiliconegelsurfaceoverlayoninterfacepressure AT aboagyesonia experimentalinterventionstudyassessingtheimpactofathinsiliconegelsurfaceoverlayoninterfacepressure AT oforierickwasi experimentalinterventionstudyassessingtheimpactofathinsiliconegelsurfaceoverlayoninterfacepressure AT hoggpeter experimentalinterventionstudyassessingtheimpactofathinsiliconegelsurfaceoverlayoninterfacepressure |