Cargando…

Long-term experience with implantable infusion pumps for intravenous treprostinil in pulmonary arterial hypertension—procedural safety and system-related complications

Implantable pumps for intravenous treprostinil provide a promising option to overcome drawbacks of parenteral prostanoid administration with external pumps in pulmonary hypertension. We retrospectively analyzed 85 patients undergoing implantation in a single center since 2010. In our cohort, serious...

Descripción completa

Detalles Bibliográficos
Autores principales: Steringer-Mascherbauer, Regina, Lummersdorfer, Maria, Függer, Reinhold, Sigmund, Elisabeth, Huber, Charlotte, Engleder, Dagmar, Fröschl, Uwe, Aichinger, Josef
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7711148/
https://www.ncbi.nlm.nih.gov/pubmed/33299542
http://dx.doi.org/10.1177/2045894020970830
_version_ 1783618085097308160
author Steringer-Mascherbauer, Regina
Lummersdorfer, Maria
Függer, Reinhold
Sigmund, Elisabeth
Huber, Charlotte
Engleder, Dagmar
Fröschl, Uwe
Aichinger, Josef
author_facet Steringer-Mascherbauer, Regina
Lummersdorfer, Maria
Függer, Reinhold
Sigmund, Elisabeth
Huber, Charlotte
Engleder, Dagmar
Fröschl, Uwe
Aichinger, Josef
author_sort Steringer-Mascherbauer, Regina
collection PubMed
description Implantable pumps for intravenous treprostinil provide a promising option to overcome drawbacks of parenteral prostanoid administration with external pumps in pulmonary hypertension. We retrospectively analyzed 85 patients undergoing implantation in a single center since 2010. In our cohort, serious complications were rare, and flow rate increase over time warrants careful monitoring.
format Online
Article
Text
id pubmed-7711148
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-77111482020-12-08 Long-term experience with implantable infusion pumps for intravenous treprostinil in pulmonary arterial hypertension—procedural safety and system-related complications Steringer-Mascherbauer, Regina Lummersdorfer, Maria Függer, Reinhold Sigmund, Elisabeth Huber, Charlotte Engleder, Dagmar Fröschl, Uwe Aichinger, Josef Pulm Circ Research Letter Implantable pumps for intravenous treprostinil provide a promising option to overcome drawbacks of parenteral prostanoid administration with external pumps in pulmonary hypertension. We retrospectively analyzed 85 patients undergoing implantation in a single center since 2010. In our cohort, serious complications were rare, and flow rate increase over time warrants careful monitoring. SAGE Publications 2020-11-30 /pmc/articles/PMC7711148/ /pubmed/33299542 http://dx.doi.org/10.1177/2045894020970830 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Research Letter
Steringer-Mascherbauer, Regina
Lummersdorfer, Maria
Függer, Reinhold
Sigmund, Elisabeth
Huber, Charlotte
Engleder, Dagmar
Fröschl, Uwe
Aichinger, Josef
Long-term experience with implantable infusion pumps for intravenous treprostinil in pulmonary arterial hypertension—procedural safety and system-related complications
title Long-term experience with implantable infusion pumps for intravenous treprostinil in pulmonary arterial hypertension—procedural safety and system-related complications
title_full Long-term experience with implantable infusion pumps for intravenous treprostinil in pulmonary arterial hypertension—procedural safety and system-related complications
title_fullStr Long-term experience with implantable infusion pumps for intravenous treprostinil in pulmonary arterial hypertension—procedural safety and system-related complications
title_full_unstemmed Long-term experience with implantable infusion pumps for intravenous treprostinil in pulmonary arterial hypertension—procedural safety and system-related complications
title_short Long-term experience with implantable infusion pumps for intravenous treprostinil in pulmonary arterial hypertension—procedural safety and system-related complications
title_sort long-term experience with implantable infusion pumps for intravenous treprostinil in pulmonary arterial hypertension—procedural safety and system-related complications
topic Research Letter
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7711148/
https://www.ncbi.nlm.nih.gov/pubmed/33299542
http://dx.doi.org/10.1177/2045894020970830
work_keys_str_mv AT steringermascherbauerregina longtermexperiencewithimplantableinfusionpumpsforintravenoustreprostinilinpulmonaryarterialhypertensionproceduralsafetyandsystemrelatedcomplications
AT lummersdorfermaria longtermexperiencewithimplantableinfusionpumpsforintravenoustreprostinilinpulmonaryarterialhypertensionproceduralsafetyandsystemrelatedcomplications
AT fuggerreinhold longtermexperiencewithimplantableinfusionpumpsforintravenoustreprostinilinpulmonaryarterialhypertensionproceduralsafetyandsystemrelatedcomplications
AT sigmundelisabeth longtermexperiencewithimplantableinfusionpumpsforintravenoustreprostinilinpulmonaryarterialhypertensionproceduralsafetyandsystemrelatedcomplications
AT hubercharlotte longtermexperiencewithimplantableinfusionpumpsforintravenoustreprostinilinpulmonaryarterialhypertensionproceduralsafetyandsystemrelatedcomplications
AT englederdagmar longtermexperiencewithimplantableinfusionpumpsforintravenoustreprostinilinpulmonaryarterialhypertensionproceduralsafetyandsystemrelatedcomplications
AT froschluwe longtermexperiencewithimplantableinfusionpumpsforintravenoustreprostinilinpulmonaryarterialhypertensionproceduralsafetyandsystemrelatedcomplications
AT aichingerjosef longtermexperiencewithimplantableinfusionpumpsforintravenoustreprostinilinpulmonaryarterialhypertensionproceduralsafetyandsystemrelatedcomplications