Cargando…
Comparing the rate of fiberoptic bronchoscopy use with a video double lumen tube versus a conventional double lumen tube—a randomized controlled trial
BACKGROUND: Double lumen endotracheal tubes (DLT) are commonly used to provide single lung ventilation during thoracic surgery. A fiberoptic bronchoscope (FOB) is typically used to confirm accurate DLT placement. Accounting for initial purchase, maintenance, repair and cleaning, the use of an FOB ca...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7711371/ https://www.ncbi.nlm.nih.gov/pubmed/33282355 http://dx.doi.org/10.21037/jtd-20-1595 |
_version_ | 1783618130488066048 |
---|---|
author | Onifade, Akinjide Lemon-Riggs, Dlorean Smith, Aaron Pak, Taylor Pruszynski, Jessica Reznik, Scott Moon, Tiffany S. |
author_facet | Onifade, Akinjide Lemon-Riggs, Dlorean Smith, Aaron Pak, Taylor Pruszynski, Jessica Reznik, Scott Moon, Tiffany S. |
author_sort | Onifade, Akinjide |
collection | PubMed |
description | BACKGROUND: Double lumen endotracheal tubes (DLT) are commonly used to provide single lung ventilation during thoracic surgery. A fiberoptic bronchoscope (FOB) is typically used to confirm accurate DLT placement. Accounting for initial purchase, maintenance, repair and cleaning, the use of an FOB can cost as much as $312 per procedure. The VivaSight DLT (VS-DLT) incorporates a built-in camera, which is aimed at reducing FOB use and its associated costs. In this study, we compared the rate of FOB use when intubating using either a VS-DLT or a conventional DLT (c-DLT). METHODS: This is a randomized controlled comparative study performed at a public county teaching hospital. A total of 50 patients were enrolled and randomly assigned to either a c-DLT (n=25) or a VS-DLT (n=25). The primary outcome was the rate of FOB use. Secondary outcomes included time to correct tube placement and incidence of malposition during surgery. RESULTS: Use of the VS-DLT required significantly less FOB use (28%) compared to use of the c-DLT (100%). While there was no difference in the ease of intubation, the time to correct tube placement was significantly faster using a VS-DLT (54 vs. 156 s, P<0.001). Additionally, the incidence of tube malposition was significantly reduced in the VS-DLT group. CONCLUSIONS: This study demonstrated a significantly lower rate of FOB use when using a VS-DLT compared to a c-DLT. Placement of the VS-DLT was significantly quicker and malposition during surgery occurred significantly less than with the c-DLT. While intubating with a VS-DLT provides clinical benefits, it may not result in significant cost reductions when compared to a c-DLT. |
format | Online Article Text |
id | pubmed-7711371 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-77113712020-12-03 Comparing the rate of fiberoptic bronchoscopy use with a video double lumen tube versus a conventional double lumen tube—a randomized controlled trial Onifade, Akinjide Lemon-Riggs, Dlorean Smith, Aaron Pak, Taylor Pruszynski, Jessica Reznik, Scott Moon, Tiffany S. J Thorac Dis Original Article BACKGROUND: Double lumen endotracheal tubes (DLT) are commonly used to provide single lung ventilation during thoracic surgery. A fiberoptic bronchoscope (FOB) is typically used to confirm accurate DLT placement. Accounting for initial purchase, maintenance, repair and cleaning, the use of an FOB can cost as much as $312 per procedure. The VivaSight DLT (VS-DLT) incorporates a built-in camera, which is aimed at reducing FOB use and its associated costs. In this study, we compared the rate of FOB use when intubating using either a VS-DLT or a conventional DLT (c-DLT). METHODS: This is a randomized controlled comparative study performed at a public county teaching hospital. A total of 50 patients were enrolled and randomly assigned to either a c-DLT (n=25) or a VS-DLT (n=25). The primary outcome was the rate of FOB use. Secondary outcomes included time to correct tube placement and incidence of malposition during surgery. RESULTS: Use of the VS-DLT required significantly less FOB use (28%) compared to use of the c-DLT (100%). While there was no difference in the ease of intubation, the time to correct tube placement was significantly faster using a VS-DLT (54 vs. 156 s, P<0.001). Additionally, the incidence of tube malposition was significantly reduced in the VS-DLT group. CONCLUSIONS: This study demonstrated a significantly lower rate of FOB use when using a VS-DLT compared to a c-DLT. Placement of the VS-DLT was significantly quicker and malposition during surgery occurred significantly less than with the c-DLT. While intubating with a VS-DLT provides clinical benefits, it may not result in significant cost reductions when compared to a c-DLT. AME Publishing Company 2020-11 /pmc/articles/PMC7711371/ /pubmed/33282355 http://dx.doi.org/10.21037/jtd-20-1595 Text en 2020 Journal of Thoracic Disease. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Onifade, Akinjide Lemon-Riggs, Dlorean Smith, Aaron Pak, Taylor Pruszynski, Jessica Reznik, Scott Moon, Tiffany S. Comparing the rate of fiberoptic bronchoscopy use with a video double lumen tube versus a conventional double lumen tube—a randomized controlled trial |
title | Comparing the rate of fiberoptic bronchoscopy use with a video double lumen tube versus a conventional double lumen tube—a randomized controlled trial |
title_full | Comparing the rate of fiberoptic bronchoscopy use with a video double lumen tube versus a conventional double lumen tube—a randomized controlled trial |
title_fullStr | Comparing the rate of fiberoptic bronchoscopy use with a video double lumen tube versus a conventional double lumen tube—a randomized controlled trial |
title_full_unstemmed | Comparing the rate of fiberoptic bronchoscopy use with a video double lumen tube versus a conventional double lumen tube—a randomized controlled trial |
title_short | Comparing the rate of fiberoptic bronchoscopy use with a video double lumen tube versus a conventional double lumen tube—a randomized controlled trial |
title_sort | comparing the rate of fiberoptic bronchoscopy use with a video double lumen tube versus a conventional double lumen tube—a randomized controlled trial |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7711371/ https://www.ncbi.nlm.nih.gov/pubmed/33282355 http://dx.doi.org/10.21037/jtd-20-1595 |
work_keys_str_mv | AT onifadeakinjide comparingtherateoffiberopticbronchoscopyusewithavideodoublelumentubeversusaconventionaldoublelumentubearandomizedcontrolledtrial AT lemonriggsdlorean comparingtherateoffiberopticbronchoscopyusewithavideodoublelumentubeversusaconventionaldoublelumentubearandomizedcontrolledtrial AT smithaaron comparingtherateoffiberopticbronchoscopyusewithavideodoublelumentubeversusaconventionaldoublelumentubearandomizedcontrolledtrial AT paktaylor comparingtherateoffiberopticbronchoscopyusewithavideodoublelumentubeversusaconventionaldoublelumentubearandomizedcontrolledtrial AT pruszynskijessica comparingtherateoffiberopticbronchoscopyusewithavideodoublelumentubeversusaconventionaldoublelumentubearandomizedcontrolledtrial AT reznikscott comparingtherateoffiberopticbronchoscopyusewithavideodoublelumentubeversusaconventionaldoublelumentubearandomizedcontrolledtrial AT moontiffanys comparingtherateoffiberopticbronchoscopyusewithavideodoublelumentubeversusaconventionaldoublelumentubearandomizedcontrolledtrial |