Diagnostic Performance of Bronchoalveolar Lavage (1,3)-β-d-Glucan Assay for Pneumocystis jirovecii Pneumonia

We evaluated the performance of the (1,3)-β-d-glucan (BDG) assay on bronchoalveolar lavage fluid (BALF) as a possible aid to the diagnosis of Pneumocystis jirovecii pneumonia. BALF samples from 18 patients with well-characterized proven, probable, and possible Pneumocystis pneumonia and 18 well-matc...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Shiwei, Linder, Kathleen A., Kauffman, Carol A., Richards, Blair J., Kleiboeker, Steve, Miceli, Marisa H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7712134/
https://www.ncbi.nlm.nih.gov/pubmed/33019729
http://dx.doi.org/10.3390/jof6040200
Descripción
Sumario:We evaluated the performance of the (1,3)-β-d-glucan (BDG) assay on bronchoalveolar lavage fluid (BALF) as a possible aid to the diagnosis of Pneumocystis jirovecii pneumonia. BALF samples from 18 patients with well-characterized proven, probable, and possible Pneumocystis pneumonia and 18 well-matched controls were tested. We found that the best test performance was observed with a cut-off value of 128 pg/mL; receiver operating characteristic/area under the curve (ROC/AUC) was 0.70 (95% CI 0.52–0.87). Sensitivity and specificity were 78% and 56%, respectively; positive predictive value was 64%, and negative predictive value was 71%. The low specificity that we noted limits the utility of BALF BDG as a diagnostic tool for Pneumocystis pneumonia.