In Vitro Evaluation of Facial Pressure and Air Leak with a Newly Designed Cushion for Non-Invasive Ventilation Masks
Background: The aim of this study was to evaluate the effect of a newly designed foam cushion on the air leakage and pressure when applied to the face. Methods: A teaching manikin connected to a bilevel positive airway pressure ventilator attached to four different brands of oronasal masks (Amara, M...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7712312/ https://www.ncbi.nlm.nih.gov/pubmed/33271748 http://dx.doi.org/10.3390/healthcare8040523 |
_version_ | 1783618346010279936 |
---|---|
author | Lin, Hui-Ling Lee, Yu-Chi Wang, Ssu-Hui Chiang, Li-Ying Liu, Jui-Fang |
author_facet | Lin, Hui-Ling Lee, Yu-Chi Wang, Ssu-Hui Chiang, Li-Ying Liu, Jui-Fang |
author_sort | Lin, Hui-Ling |
collection | PubMed |
description | Background: The aim of this study was to evaluate the effect of a newly designed foam cushion on the air leakage and pressure when applied to the face. Methods: A teaching manikin connected to a bilevel positive airway pressure ventilator attached to four different brands of oronasal masks (Amara, Mirage, Forma, and Wizard) was used. The foam cushions of 5-mm and 10-mm-thickness were attached to the masks, and each mask was tested without a cushion. Six pressure sensors were placed on the manikin’s face, and data were recorded. Inspiratory volume and air leak flow from the ventilator were observed. Results: Air leakage was influenced by both the mask brand and the presence of a cushion. The presence of a cushion did not affect the Wizard mask in terms of leakage (p = 0.317) or inspiratory volume (p = 0.726). The Wizard and Amara masks generated the lowest contact pressure on the frontal forehead (p < 0.001) compared to the other five points. Conclusions: Utilisation of a cushion reduces air leakage and maintains greater inspiratory volume regardless of its thickness. The contact pressure varies depending on the brand of the mask, which would require a difference in the thickness of the cushion for pressure reduction. |
format | Online Article Text |
id | pubmed-7712312 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77123122020-12-04 In Vitro Evaluation of Facial Pressure and Air Leak with a Newly Designed Cushion for Non-Invasive Ventilation Masks Lin, Hui-Ling Lee, Yu-Chi Wang, Ssu-Hui Chiang, Li-Ying Liu, Jui-Fang Healthcare (Basel) Article Background: The aim of this study was to evaluate the effect of a newly designed foam cushion on the air leakage and pressure when applied to the face. Methods: A teaching manikin connected to a bilevel positive airway pressure ventilator attached to four different brands of oronasal masks (Amara, Mirage, Forma, and Wizard) was used. The foam cushions of 5-mm and 10-mm-thickness were attached to the masks, and each mask was tested without a cushion. Six pressure sensors were placed on the manikin’s face, and data were recorded. Inspiratory volume and air leak flow from the ventilator were observed. Results: Air leakage was influenced by both the mask brand and the presence of a cushion. The presence of a cushion did not affect the Wizard mask in terms of leakage (p = 0.317) or inspiratory volume (p = 0.726). The Wizard and Amara masks generated the lowest contact pressure on the frontal forehead (p < 0.001) compared to the other five points. Conclusions: Utilisation of a cushion reduces air leakage and maintains greater inspiratory volume regardless of its thickness. The contact pressure varies depending on the brand of the mask, which would require a difference in the thickness of the cushion for pressure reduction. MDPI 2020-12-01 /pmc/articles/PMC7712312/ /pubmed/33271748 http://dx.doi.org/10.3390/healthcare8040523 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lin, Hui-Ling Lee, Yu-Chi Wang, Ssu-Hui Chiang, Li-Ying Liu, Jui-Fang In Vitro Evaluation of Facial Pressure and Air Leak with a Newly Designed Cushion for Non-Invasive Ventilation Masks |
title | In Vitro Evaluation of Facial Pressure and Air Leak with a Newly Designed Cushion for Non-Invasive Ventilation Masks |
title_full | In Vitro Evaluation of Facial Pressure and Air Leak with a Newly Designed Cushion for Non-Invasive Ventilation Masks |
title_fullStr | In Vitro Evaluation of Facial Pressure and Air Leak with a Newly Designed Cushion for Non-Invasive Ventilation Masks |
title_full_unstemmed | In Vitro Evaluation of Facial Pressure and Air Leak with a Newly Designed Cushion for Non-Invasive Ventilation Masks |
title_short | In Vitro Evaluation of Facial Pressure and Air Leak with a Newly Designed Cushion for Non-Invasive Ventilation Masks |
title_sort | in vitro evaluation of facial pressure and air leak with a newly designed cushion for non-invasive ventilation masks |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7712312/ https://www.ncbi.nlm.nih.gov/pubmed/33271748 http://dx.doi.org/10.3390/healthcare8040523 |
work_keys_str_mv | AT linhuiling invitroevaluationoffacialpressureandairleakwithanewlydesignedcushionfornoninvasiveventilationmasks AT leeyuchi invitroevaluationoffacialpressureandairleakwithanewlydesignedcushionfornoninvasiveventilationmasks AT wangssuhui invitroevaluationoffacialpressureandairleakwithanewlydesignedcushionfornoninvasiveventilationmasks AT chiangliying invitroevaluationoffacialpressureandairleakwithanewlydesignedcushionfornoninvasiveventilationmasks AT liujuifang invitroevaluationoffacialpressureandairleakwithanewlydesignedcushionfornoninvasiveventilationmasks |