Cargando…

Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration

In 2015, the newborn screening (NBS) programmes in England and Wales were expanded to include four additional disorders: Classical Homocystinuria, Isovaleric Acidemia, Glutaric Aciduria Type 1 and Maple Syrup Urine Disease, bringing the total number of analytes quantified to eight: phenylalanine, ty...

Descripción completa

Detalles Bibliográficos
Autores principales: Carling, Rachel S., John, Catharine, Goddard, Philippa, Griffith, Caroline, Cowen, Simon, Hopley, Christopher, Moat, Stuart J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7712741/
https://www.ncbi.nlm.nih.gov/pubmed/33228114
http://dx.doi.org/10.3390/ijns6040092
_version_ 1783618434540503040
author Carling, Rachel S.
John, Catharine
Goddard, Philippa
Griffith, Caroline
Cowen, Simon
Hopley, Christopher
Moat, Stuart J.
author_facet Carling, Rachel S.
John, Catharine
Goddard, Philippa
Griffith, Caroline
Cowen, Simon
Hopley, Christopher
Moat, Stuart J.
author_sort Carling, Rachel S.
collection PubMed
description In 2015, the newborn screening (NBS) programmes in England and Wales were expanded to include four additional disorders: Classical Homocystinuria, Isovaleric Acidemia, Glutaric Aciduria Type 1 and Maple Syrup Urine Disease, bringing the total number of analytes quantified to eight: phenylalanine, tyrosine, leucine, methionine, isovalerylcarnitine, glutarylcarnitine, octanoylcarnitine and decanoylcarnitine. Post-implementation, population data monitoring showed that inter-laboratory variation was greater than expected, with 90th centiles varying from 17% to 59%. We evaluated the effect of stable isotope internal standard (IS) used for quantitation on inter-laboratory variation. Four laboratories analysed routine screening samples (n > 101,820) using a common IS. Inter-laboratory variation was determined for the eight analytes and compared with results obtained using an in-house common IS (n > 102,194). A linear mixed-effects model was fitted to the data. Using a common IS mix reduced the inter-laboratory variation significantly (p < 0.05) for five analytes. For three analytes, the lack of significance was explained by use of individual laboratory “calibration factors”. For screening programmes where laboratories adhere to single analyte cut-off values (COVs), it is important that inter-laboratory variation is minimised, primarily to prevent false positive results. Whilst the use of a common IS helps achieve this, it is evident that instrument set-up also contributes to inter-laboratory variation.
format Online
Article
Text
id pubmed-7712741
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77127412020-12-04 Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration Carling, Rachel S. John, Catharine Goddard, Philippa Griffith, Caroline Cowen, Simon Hopley, Christopher Moat, Stuart J. Int J Neonatal Screen Article In 2015, the newborn screening (NBS) programmes in England and Wales were expanded to include four additional disorders: Classical Homocystinuria, Isovaleric Acidemia, Glutaric Aciduria Type 1 and Maple Syrup Urine Disease, bringing the total number of analytes quantified to eight: phenylalanine, tyrosine, leucine, methionine, isovalerylcarnitine, glutarylcarnitine, octanoylcarnitine and decanoylcarnitine. Post-implementation, population data monitoring showed that inter-laboratory variation was greater than expected, with 90th centiles varying from 17% to 59%. We evaluated the effect of stable isotope internal standard (IS) used for quantitation on inter-laboratory variation. Four laboratories analysed routine screening samples (n > 101,820) using a common IS. Inter-laboratory variation was determined for the eight analytes and compared with results obtained using an in-house common IS (n > 102,194). A linear mixed-effects model was fitted to the data. Using a common IS mix reduced the inter-laboratory variation significantly (p < 0.05) for five analytes. For three analytes, the lack of significance was explained by use of individual laboratory “calibration factors”. For screening programmes where laboratories adhere to single analyte cut-off values (COVs), it is important that inter-laboratory variation is minimised, primarily to prevent false positive results. Whilst the use of a common IS helps achieve this, it is evident that instrument set-up also contributes to inter-laboratory variation. MDPI 2020-11-19 /pmc/articles/PMC7712741/ /pubmed/33228114 http://dx.doi.org/10.3390/ijns6040092 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Carling, Rachel S.
John, Catharine
Goddard, Philippa
Griffith, Caroline
Cowen, Simon
Hopley, Christopher
Moat, Stuart J.
Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration
title Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration
title_full Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration
title_fullStr Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration
title_full_unstemmed Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration
title_short Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration
title_sort evaluation of a common internal standard material to reduce inter-laboratory variation and ensure the quality, safety and efficacy of expanded newborn screening results when using flow injection analysis tandem mass spectrometry with internal calibration
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7712741/
https://www.ncbi.nlm.nih.gov/pubmed/33228114
http://dx.doi.org/10.3390/ijns6040092
work_keys_str_mv AT carlingrachels evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration
AT johncatharine evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration
AT goddardphilippa evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration
AT griffithcaroline evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration
AT cowensimon evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration
AT hopleychristopher evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration
AT moatstuartj evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration