Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration
In 2015, the newborn screening (NBS) programmes in England and Wales were expanded to include four additional disorders: Classical Homocystinuria, Isovaleric Acidemia, Glutaric Aciduria Type 1 and Maple Syrup Urine Disease, bringing the total number of analytes quantified to eight: phenylalanine, ty...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7712741/ https://www.ncbi.nlm.nih.gov/pubmed/33228114 http://dx.doi.org/10.3390/ijns6040092 |
_version_ | 1783618434540503040 |
---|---|
author | Carling, Rachel S. John, Catharine Goddard, Philippa Griffith, Caroline Cowen, Simon Hopley, Christopher Moat, Stuart J. |
author_facet | Carling, Rachel S. John, Catharine Goddard, Philippa Griffith, Caroline Cowen, Simon Hopley, Christopher Moat, Stuart J. |
author_sort | Carling, Rachel S. |
collection | PubMed |
description | In 2015, the newborn screening (NBS) programmes in England and Wales were expanded to include four additional disorders: Classical Homocystinuria, Isovaleric Acidemia, Glutaric Aciduria Type 1 and Maple Syrup Urine Disease, bringing the total number of analytes quantified to eight: phenylalanine, tyrosine, leucine, methionine, isovalerylcarnitine, glutarylcarnitine, octanoylcarnitine and decanoylcarnitine. Post-implementation, population data monitoring showed that inter-laboratory variation was greater than expected, with 90th centiles varying from 17% to 59%. We evaluated the effect of stable isotope internal standard (IS) used for quantitation on inter-laboratory variation. Four laboratories analysed routine screening samples (n > 101,820) using a common IS. Inter-laboratory variation was determined for the eight analytes and compared with results obtained using an in-house common IS (n > 102,194). A linear mixed-effects model was fitted to the data. Using a common IS mix reduced the inter-laboratory variation significantly (p < 0.05) for five analytes. For three analytes, the lack of significance was explained by use of individual laboratory “calibration factors”. For screening programmes where laboratories adhere to single analyte cut-off values (COVs), it is important that inter-laboratory variation is minimised, primarily to prevent false positive results. Whilst the use of a common IS helps achieve this, it is evident that instrument set-up also contributes to inter-laboratory variation. |
format | Online Article Text |
id | pubmed-7712741 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77127412020-12-04 Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration Carling, Rachel S. John, Catharine Goddard, Philippa Griffith, Caroline Cowen, Simon Hopley, Christopher Moat, Stuart J. Int J Neonatal Screen Article In 2015, the newborn screening (NBS) programmes in England and Wales were expanded to include four additional disorders: Classical Homocystinuria, Isovaleric Acidemia, Glutaric Aciduria Type 1 and Maple Syrup Urine Disease, bringing the total number of analytes quantified to eight: phenylalanine, tyrosine, leucine, methionine, isovalerylcarnitine, glutarylcarnitine, octanoylcarnitine and decanoylcarnitine. Post-implementation, population data monitoring showed that inter-laboratory variation was greater than expected, with 90th centiles varying from 17% to 59%. We evaluated the effect of stable isotope internal standard (IS) used for quantitation on inter-laboratory variation. Four laboratories analysed routine screening samples (n > 101,820) using a common IS. Inter-laboratory variation was determined for the eight analytes and compared with results obtained using an in-house common IS (n > 102,194). A linear mixed-effects model was fitted to the data. Using a common IS mix reduced the inter-laboratory variation significantly (p < 0.05) for five analytes. For three analytes, the lack of significance was explained by use of individual laboratory “calibration factors”. For screening programmes where laboratories adhere to single analyte cut-off values (COVs), it is important that inter-laboratory variation is minimised, primarily to prevent false positive results. Whilst the use of a common IS helps achieve this, it is evident that instrument set-up also contributes to inter-laboratory variation. MDPI 2020-11-19 /pmc/articles/PMC7712741/ /pubmed/33228114 http://dx.doi.org/10.3390/ijns6040092 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Carling, Rachel S. John, Catharine Goddard, Philippa Griffith, Caroline Cowen, Simon Hopley, Christopher Moat, Stuart J. Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration |
title | Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration |
title_full | Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration |
title_fullStr | Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration |
title_full_unstemmed | Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration |
title_short | Evaluation of a Common Internal Standard Material to Reduce Inter-Laboratory Variation and Ensure the Quality, Safety and Efficacy of Expanded Newborn Screening Results When Using Flow Injection Analysis Tandem Mass Spectrometry with Internal Calibration |
title_sort | evaluation of a common internal standard material to reduce inter-laboratory variation and ensure the quality, safety and efficacy of expanded newborn screening results when using flow injection analysis tandem mass spectrometry with internal calibration |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7712741/ https://www.ncbi.nlm.nih.gov/pubmed/33228114 http://dx.doi.org/10.3390/ijns6040092 |
work_keys_str_mv | AT carlingrachels evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration AT johncatharine evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration AT goddardphilippa evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration AT griffithcaroline evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration AT cowensimon evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration AT hopleychristopher evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration AT moatstuartj evaluationofacommoninternalstandardmaterialtoreduceinterlaboratoryvariationandensurethequalitysafetyandefficacyofexpandednewbornscreeningresultswhenusingflowinjectionanalysistandemmassspectrometrywithinternalcalibration |