Fall inducing movable platform (FIMP) for overground trips and slips

BACKGROUND: The study of falls and fall prevention/intervention devices requires the recording of true falls incidence. However, true falls are rare, random, and difficult to collect in real world settings. A system capable of producing falls in an ecologically valid manner will be very helpful in c...

Descripción completa

Detalles Bibliográficos
Autores principales: Er, Jie Kai, Donnelly, Cyril John William, Wee, Seng Kwee, Ang, Wei Tech
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7713354/
https://www.ncbi.nlm.nih.gov/pubmed/33272286
http://dx.doi.org/10.1186/s12984-020-00785-0
_version_ 1783618561874329600
author Er, Jie Kai
Donnelly, Cyril John William
Wee, Seng Kwee
Ang, Wei Tech
author_facet Er, Jie Kai
Donnelly, Cyril John William
Wee, Seng Kwee
Ang, Wei Tech
author_sort Er, Jie Kai
collection PubMed
description BACKGROUND: The study of falls and fall prevention/intervention devices requires the recording of true falls incidence. However, true falls are rare, random, and difficult to collect in real world settings. A system capable of producing falls in an ecologically valid manner will be very helpful in collecting the data necessary to advance our understanding of the neuro and musculoskeletal mechanisms underpinning real-world falls events. METHODS: A fall inducing movable platform (FIMP) was designed to arrest or accelerate a subject’s ankle to induce a trip or slip. The ankle was arrested posteriorly with an electromagnetic brake and accelerated anteriorly with a motor. A power spring was connected in series between the ankle and the brake/motor to allow freedom of movement (system transparency) when a fall is not being induced. A gait phase detection algorithm was also created to enable precise activation of the fall inducing mechanisms. Statistical Parametric Mapping (SPM1D) and one-way repeated measure ANOVA were used to evaluate the ability of the FIMP to induce a trip or slip. RESULTS: During FIMP induced trips, the brake activates at the terminal swing or mid swing gait phase to induce the lowering or skipping strategies, respectively. For the lowering strategy, the characteristic leg lowering and subsequent contralateral leg swing was seen in all subjects. Likewise, for the skipping strategy, all subjects skipped forward on the perturbed leg. Slip was induced by FIMP by using a motor to impart unwanted forward acceleration to the ankle with the help of friction-reducing ground sliding sheets. Joint stiffening was observed during the slips, and subjects universally adopted the surfing strategy after the initial slip. CONCLUSION: The results indicate that FIMP can induce ecologically valid falls under controlled laboratory conditions. The use of SPM1D in conjunction with FIMP allows for the time varying statistical quantification of trip and slip reactive kinematics events. With future research, fall recovery anomalies in subjects can now also be systematically evaluated through the assessment of other neuromuscular variables such as joint forces, muscle activation and muscle forces.
format Online
Article
Text
id pubmed-7713354
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-77133542020-12-03 Fall inducing movable platform (FIMP) for overground trips and slips Er, Jie Kai Donnelly, Cyril John William Wee, Seng Kwee Ang, Wei Tech J Neuroeng Rehabil Research BACKGROUND: The study of falls and fall prevention/intervention devices requires the recording of true falls incidence. However, true falls are rare, random, and difficult to collect in real world settings. A system capable of producing falls in an ecologically valid manner will be very helpful in collecting the data necessary to advance our understanding of the neuro and musculoskeletal mechanisms underpinning real-world falls events. METHODS: A fall inducing movable platform (FIMP) was designed to arrest or accelerate a subject’s ankle to induce a trip or slip. The ankle was arrested posteriorly with an electromagnetic brake and accelerated anteriorly with a motor. A power spring was connected in series between the ankle and the brake/motor to allow freedom of movement (system transparency) when a fall is not being induced. A gait phase detection algorithm was also created to enable precise activation of the fall inducing mechanisms. Statistical Parametric Mapping (SPM1D) and one-way repeated measure ANOVA were used to evaluate the ability of the FIMP to induce a trip or slip. RESULTS: During FIMP induced trips, the brake activates at the terminal swing or mid swing gait phase to induce the lowering or skipping strategies, respectively. For the lowering strategy, the characteristic leg lowering and subsequent contralateral leg swing was seen in all subjects. Likewise, for the skipping strategy, all subjects skipped forward on the perturbed leg. Slip was induced by FIMP by using a motor to impart unwanted forward acceleration to the ankle with the help of friction-reducing ground sliding sheets. Joint stiffening was observed during the slips, and subjects universally adopted the surfing strategy after the initial slip. CONCLUSION: The results indicate that FIMP can induce ecologically valid falls under controlled laboratory conditions. The use of SPM1D in conjunction with FIMP allows for the time varying statistical quantification of trip and slip reactive kinematics events. With future research, fall recovery anomalies in subjects can now also be systematically evaluated through the assessment of other neuromuscular variables such as joint forces, muscle activation and muscle forces. BioMed Central 2020-12-03 /pmc/articles/PMC7713354/ /pubmed/33272286 http://dx.doi.org/10.1186/s12984-020-00785-0 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Er, Jie Kai
Donnelly, Cyril John William
Wee, Seng Kwee
Ang, Wei Tech
Fall inducing movable platform (FIMP) for overground trips and slips
title Fall inducing movable platform (FIMP) for overground trips and slips
title_full Fall inducing movable platform (FIMP) for overground trips and slips
title_fullStr Fall inducing movable platform (FIMP) for overground trips and slips
title_full_unstemmed Fall inducing movable platform (FIMP) for overground trips and slips
title_short Fall inducing movable platform (FIMP) for overground trips and slips
title_sort fall inducing movable platform (fimp) for overground trips and slips
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7713354/
https://www.ncbi.nlm.nih.gov/pubmed/33272286
http://dx.doi.org/10.1186/s12984-020-00785-0
work_keys_str_mv AT erjiekai fallinducingmovableplatformfimpforovergroundtripsandslips
AT donnellycyriljohnwilliam fallinducingmovableplatformfimpforovergroundtripsandslips
AT weesengkwee fallinducingmovableplatformfimpforovergroundtripsandslips
AT angweitech fallinducingmovableplatformfimpforovergroundtripsandslips