Cargando…

Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty

Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedur...

Descripción completa

Detalles Bibliográficos
Autores principales: Jo, Young-Hoon, Lee, Seung Gun, Kook, Incheol, Lee, Bong Gun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Shoulder and Elbow Society 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7714294/
https://www.ncbi.nlm.nih.gov/pubmed/33330250
http://dx.doi.org/10.5397/cise.2020.00213
_version_ 1783618724384735232
author Jo, Young-Hoon
Lee, Seung Gun
Kook, Incheol
Lee, Bong Gun
author_facet Jo, Young-Hoon
Lee, Seung Gun
Kook, Incheol
Lee, Bong Gun
author_sort Jo, Young-Hoon
collection PubMed
description Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and cerclage wire for periprosthetic fracture, allogenous fibular strut bone inserted into the humerus intramedullary canal allowing the fractured site to be more stable without cement usage. At 10-month follow-up, the complete union and good clinical outcome was achieved. We present a novel technique for treating periprosthetic fracture with implant loosening after total elbow replacement surgery, using intramedullary allogenous fibula strut bone graft.
format Online
Article
Text
id pubmed-7714294
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Korean Shoulder and Elbow Society
record_format MEDLINE/PubMed
spelling pubmed-77142942020-12-15 Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty Jo, Young-Hoon Lee, Seung Gun Kook, Incheol Lee, Bong Gun Clin Shoulder Elb Technical Note Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and cerclage wire for periprosthetic fracture, allogenous fibular strut bone inserted into the humerus intramedullary canal allowing the fractured site to be more stable without cement usage. At 10-month follow-up, the complete union and good clinical outcome was achieved. We present a novel technique for treating periprosthetic fracture with implant loosening after total elbow replacement surgery, using intramedullary allogenous fibula strut bone graft. Korean Shoulder and Elbow Society 2020-09-01 /pmc/articles/PMC7714294/ /pubmed/33330250 http://dx.doi.org/10.5397/cise.2020.00213 Text en Copyright © 2020 Korean Shoulder and Elbow Society This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Note
Jo, Young-Hoon
Lee, Seung Gun
Kook, Incheol
Lee, Bong Gun
Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty
title Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty
title_full Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty
title_fullStr Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty
title_full_unstemmed Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty
title_short Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty
title_sort intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7714294/
https://www.ncbi.nlm.nih.gov/pubmed/33330250
http://dx.doi.org/10.5397/cise.2020.00213
work_keys_str_mv AT joyounghoon intramedullaryfibulastrutboneallograftinaperiprosthetichumeralshaftfracturewithimplantlooseningaftertotalelbowarthroplasty
AT leeseunggun intramedullaryfibulastrutboneallograftinaperiprosthetichumeralshaftfracturewithimplantlooseningaftertotalelbowarthroplasty
AT kookincheol intramedullaryfibulastrutboneallograftinaperiprosthetichumeralshaftfracturewithimplantlooseningaftertotalelbowarthroplasty
AT leebonggun intramedullaryfibulastrutboneallograftinaperiprosthetichumeralshaftfracturewithimplantlooseningaftertotalelbowarthroplasty