Cargando…

An Individualized Intra-Articular Stabilization Device Designed Based on 3D Printing Technology for Traumatic Instability of the Ulnohumeral Joint

We aimed to design an individualized intra-articular stabilization device based on 3D printing technology and investigate the clinical effects of this device for treating traumatic instability of the ulnohumeral joint. This study enrolled nine patients with traumatic instability of the ulnohumeral j...

Descripción completa

Detalles Bibliográficos
Autores principales: She, Rong-Feng, Zhang, Yi, Zhang, Bin, Wang, Yuan-Zheng, Huang, Qi-Xiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7714564/
https://www.ncbi.nlm.nih.gov/pubmed/33294437
http://dx.doi.org/10.1155/2020/3056395
_version_ 1783618769645469696
author She, Rong-Feng
Zhang, Yi
Zhang, Bin
Wang, Yuan-Zheng
Huang, Qi-Xiang
author_facet She, Rong-Feng
Zhang, Yi
Zhang, Bin
Wang, Yuan-Zheng
Huang, Qi-Xiang
author_sort She, Rong-Feng
collection PubMed
description We aimed to design an individualized intra-articular stabilization device based on 3D printing technology and investigate the clinical effects of this device for treating traumatic instability of the ulnohumeral joint. This study enrolled nine patients with traumatic instability of the ulnohumeral joint (age: 47.2 ± 1.80 years) who received treatment between March 2018 and March 2019 in our hospital. All patients underwent a thin-layer computed tomography (CT) scan of the elbow before surgery. The original injury and repair models of the elbow were printed using 3D printing technology based on CT data. An individualized intra-articular stabilization device was designed with a 2.0 mm Kirschner wire based on the repair model. Nine patients agreed to receive surgical treatment for elbow disease and placement of the intra-articular stabilization device. The nine patients underwent open reduction through a posterior median approach, and the intra-articular stabilization device was placed in the elbow. Operation time, intraoperative blood loss, and postoperative complications were recorded and followed up. The device was removed at two postoperative months, and the Mayo score was used to evaluate elbow function. Four months after removing the intra-articular stabilization device, elbow joint function was evaluated again using the Mayo score. The mean operation time was 100.1 ± 8.2 min, and the mean intraoperative blood loss was 35.5 ± 7.1 ml. No complications occurred after operation. Two months after surgery, eight patients received an excellent Mayo score, and one patient received a good Mayo score. Four months after removal of the intra-articular stabilization device, eight patients received an excellent Mayo score, and one patient received a good Mayo score. The individualized intra-articular stabilization device can increase ulnohumeral stability and achieve rapid functional recovery of the elbow.
format Online
Article
Text
id pubmed-7714564
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-77145642020-12-07 An Individualized Intra-Articular Stabilization Device Designed Based on 3D Printing Technology for Traumatic Instability of the Ulnohumeral Joint She, Rong-Feng Zhang, Yi Zhang, Bin Wang, Yuan-Zheng Huang, Qi-Xiang Biomed Res Int Research Article We aimed to design an individualized intra-articular stabilization device based on 3D printing technology and investigate the clinical effects of this device for treating traumatic instability of the ulnohumeral joint. This study enrolled nine patients with traumatic instability of the ulnohumeral joint (age: 47.2 ± 1.80 years) who received treatment between March 2018 and March 2019 in our hospital. All patients underwent a thin-layer computed tomography (CT) scan of the elbow before surgery. The original injury and repair models of the elbow were printed using 3D printing technology based on CT data. An individualized intra-articular stabilization device was designed with a 2.0 mm Kirschner wire based on the repair model. Nine patients agreed to receive surgical treatment for elbow disease and placement of the intra-articular stabilization device. The nine patients underwent open reduction through a posterior median approach, and the intra-articular stabilization device was placed in the elbow. Operation time, intraoperative blood loss, and postoperative complications were recorded and followed up. The device was removed at two postoperative months, and the Mayo score was used to evaluate elbow function. Four months after removing the intra-articular stabilization device, elbow joint function was evaluated again using the Mayo score. The mean operation time was 100.1 ± 8.2 min, and the mean intraoperative blood loss was 35.5 ± 7.1 ml. No complications occurred after operation. Two months after surgery, eight patients received an excellent Mayo score, and one patient received a good Mayo score. Four months after removal of the intra-articular stabilization device, eight patients received an excellent Mayo score, and one patient received a good Mayo score. The individualized intra-articular stabilization device can increase ulnohumeral stability and achieve rapid functional recovery of the elbow. Hindawi 2020-11-25 /pmc/articles/PMC7714564/ /pubmed/33294437 http://dx.doi.org/10.1155/2020/3056395 Text en Copyright © 2020 Rong-Feng She et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
She, Rong-Feng
Zhang, Yi
Zhang, Bin
Wang, Yuan-Zheng
Huang, Qi-Xiang
An Individualized Intra-Articular Stabilization Device Designed Based on 3D Printing Technology for Traumatic Instability of the Ulnohumeral Joint
title An Individualized Intra-Articular Stabilization Device Designed Based on 3D Printing Technology for Traumatic Instability of the Ulnohumeral Joint
title_full An Individualized Intra-Articular Stabilization Device Designed Based on 3D Printing Technology for Traumatic Instability of the Ulnohumeral Joint
title_fullStr An Individualized Intra-Articular Stabilization Device Designed Based on 3D Printing Technology for Traumatic Instability of the Ulnohumeral Joint
title_full_unstemmed An Individualized Intra-Articular Stabilization Device Designed Based on 3D Printing Technology for Traumatic Instability of the Ulnohumeral Joint
title_short An Individualized Intra-Articular Stabilization Device Designed Based on 3D Printing Technology for Traumatic Instability of the Ulnohumeral Joint
title_sort individualized intra-articular stabilization device designed based on 3d printing technology for traumatic instability of the ulnohumeral joint
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7714564/
https://www.ncbi.nlm.nih.gov/pubmed/33294437
http://dx.doi.org/10.1155/2020/3056395
work_keys_str_mv AT sherongfeng anindividualizedintraarticularstabilizationdevicedesignedbasedon3dprintingtechnologyfortraumaticinstabilityoftheulnohumeraljoint
AT zhangyi anindividualizedintraarticularstabilizationdevicedesignedbasedon3dprintingtechnologyfortraumaticinstabilityoftheulnohumeraljoint
AT zhangbin anindividualizedintraarticularstabilizationdevicedesignedbasedon3dprintingtechnologyfortraumaticinstabilityoftheulnohumeraljoint
AT wangyuanzheng anindividualizedintraarticularstabilizationdevicedesignedbasedon3dprintingtechnologyfortraumaticinstabilityoftheulnohumeraljoint
AT huangqixiang anindividualizedintraarticularstabilizationdevicedesignedbasedon3dprintingtechnologyfortraumaticinstabilityoftheulnohumeraljoint
AT sherongfeng individualizedintraarticularstabilizationdevicedesignedbasedon3dprintingtechnologyfortraumaticinstabilityoftheulnohumeraljoint
AT zhangyi individualizedintraarticularstabilizationdevicedesignedbasedon3dprintingtechnologyfortraumaticinstabilityoftheulnohumeraljoint
AT zhangbin individualizedintraarticularstabilizationdevicedesignedbasedon3dprintingtechnologyfortraumaticinstabilityoftheulnohumeraljoint
AT wangyuanzheng individualizedintraarticularstabilizationdevicedesignedbasedon3dprintingtechnologyfortraumaticinstabilityoftheulnohumeraljoint
AT huangqixiang individualizedintraarticularstabilizationdevicedesignedbasedon3dprintingtechnologyfortraumaticinstabilityoftheulnohumeraljoint