Embolization of the false lumen using IMPEDE-FX embolization plugs as part of treatment of an infrarenal post-dissection aneurysm: a case report
BACKGROUND: This case report demonstrates the value of IMPEDE-FX plugs in an embolization procedure of a false lumen of an infrarenal post-dissection aneurysm. CASE PRESENTATION: A 69-year-old patient was treated with mitral valve replacement, complicated by a Stanford type-A dissection. After 9 yea...
Autores principales: | Jansen, Anne-Jet S., van Schaik, Paul M., Martens, Jasper M., Reijnen, Michel M. P. J. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7718367/ https://www.ncbi.nlm.nih.gov/pubmed/33275193 http://dx.doi.org/10.1186/s42155-020-00183-6 |
Ejemplares similares
-
False Lumen Embolization with the Candy Plug Technique for Consumptive Coagulopathy after Aortic Repair for Chronic Dissection
por: Hasegawa, Shota, et al.
Publicado: (2019) -
Initial experience with a modified “candy-plug” technique for false lumen embolization in chronic type B aortic dissection
por: Miles, Daniel, et al.
Publicado: (2022) -
Intercostal artery embolization to induce false lumen thrombosis in type B aortic dissection
por: Magee, Gregory A., et al.
Publicado: (2020) -
A modified candy-plug technique to occlude false lumen in aortic dissection
por: Palm, Erik, et al.
Publicado: (2022) -
False lumen embolization as a rescue technique in the setting of acute and chronic dissecting aneurysms as adjunct to thoracic endovascular aortic repair
por: Rakestraw, Stephanie, et al.
Publicado: (2020)