Cargando…

Comparative Study of Auto Plan and Manual Plan for Nasopharyngeal Carcinoma Intensity-Modulated Radiation Therapy

PURPOSE AND OBJECTIVE: Auto planning might reduce the manual time required for the optimization and could also potentially improve the overall plan quality. The aim of this study is to demonstrate the statistical comparison of automatic (AU) and manually (MA) generated nasopharyngeal carcinoma (NPC)...

Descripción completa

Detalles Bibliográficos
Autores principales: Xin, Xin, Cheng, Chuandong, Li, Churong, Li, Jie, Wang, Pei, Yin, Gang, Lang, Jinyi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7719327/
https://www.ncbi.nlm.nih.gov/pubmed/33293869
http://dx.doi.org/10.2147/CMAR.S226495
_version_ 1783619656957820928
author Xin, Xin
Cheng, Chuandong
Li, Churong
Li, Jie
Wang, Pei
Yin, Gang
Lang, Jinyi
author_facet Xin, Xin
Cheng, Chuandong
Li, Churong
Li, Jie
Wang, Pei
Yin, Gang
Lang, Jinyi
author_sort Xin, Xin
collection PubMed
description PURPOSE AND OBJECTIVE: Auto planning might reduce the manual time required for the optimization and could also potentially improve the overall plan quality. The aim of this study is to demonstrate the statistical comparison of automatic (AU) and manually (MA) generated nasopharyngeal carcinoma (NPC) intensity-modulated radiation therapy (IMRT) plans. MATERIALS AND METHODS: The study included 105 nasopharyngeal carcinoma patients, admitted to our hospital. The patients underwent IMRT treatments. The clinically delivered plans were performed with Eclipse (Version 11.0) using manual optimization. The same plans were optimized successively in Pinnacle(TM3) (version 9.10) treatment planning system using the auto plan software package module. D95 (dose of 95% volume) and D98 (dose of 98% volume) were calculated for the targets and maximum dose (Dmax) and mean dose (Dmean) for the organ at risks (OARs); moreover, the average doses of each target and OARs for 105 patients were evaluated. RESULTS: There is no significant difference in the homogeneity of the target between AU and MA treatment plans, while a significant difference is observed for what is concerning the OARs or most of OARs in 105 patients, OAR doses were significantly reduced in AU plan. For OARs which have no significant difference between AU and MA plans are highlighted, the mean dose of OARs in AU plans was at least not higher than MA plans. CONCLUSION: Nasopharyngeal carcinoma IMRT plans made by an automatic planning tool met the clinical requirements for target prescription dose; moreover, the dose of normal tissues was lower than in MA plans. Clinical physicists' time can be saved and the influence of factors such as the lack of experience in treatment planning can be avoided.
format Online
Article
Text
id pubmed-7719327
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-77193272020-12-07 Comparative Study of Auto Plan and Manual Plan for Nasopharyngeal Carcinoma Intensity-Modulated Radiation Therapy Xin, Xin Cheng, Chuandong Li, Churong Li, Jie Wang, Pei Yin, Gang Lang, Jinyi Cancer Manag Res Original Research PURPOSE AND OBJECTIVE: Auto planning might reduce the manual time required for the optimization and could also potentially improve the overall plan quality. The aim of this study is to demonstrate the statistical comparison of automatic (AU) and manually (MA) generated nasopharyngeal carcinoma (NPC) intensity-modulated radiation therapy (IMRT) plans. MATERIALS AND METHODS: The study included 105 nasopharyngeal carcinoma patients, admitted to our hospital. The patients underwent IMRT treatments. The clinically delivered plans were performed with Eclipse (Version 11.0) using manual optimization. The same plans were optimized successively in Pinnacle(TM3) (version 9.10) treatment planning system using the auto plan software package module. D95 (dose of 95% volume) and D98 (dose of 98% volume) were calculated for the targets and maximum dose (Dmax) and mean dose (Dmean) for the organ at risks (OARs); moreover, the average doses of each target and OARs for 105 patients were evaluated. RESULTS: There is no significant difference in the homogeneity of the target between AU and MA treatment plans, while a significant difference is observed for what is concerning the OARs or most of OARs in 105 patients, OAR doses were significantly reduced in AU plan. For OARs which have no significant difference between AU and MA plans are highlighted, the mean dose of OARs in AU plans was at least not higher than MA plans. CONCLUSION: Nasopharyngeal carcinoma IMRT plans made by an automatic planning tool met the clinical requirements for target prescription dose; moreover, the dose of normal tissues was lower than in MA plans. Clinical physicists' time can be saved and the influence of factors such as the lack of experience in treatment planning can be avoided. Dove 2020-12-02 /pmc/articles/PMC7719327/ /pubmed/33293869 http://dx.doi.org/10.2147/CMAR.S226495 Text en © 2020 Xin et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Xin, Xin
Cheng, Chuandong
Li, Churong
Li, Jie
Wang, Pei
Yin, Gang
Lang, Jinyi
Comparative Study of Auto Plan and Manual Plan for Nasopharyngeal Carcinoma Intensity-Modulated Radiation Therapy
title Comparative Study of Auto Plan and Manual Plan for Nasopharyngeal Carcinoma Intensity-Modulated Radiation Therapy
title_full Comparative Study of Auto Plan and Manual Plan for Nasopharyngeal Carcinoma Intensity-Modulated Radiation Therapy
title_fullStr Comparative Study of Auto Plan and Manual Plan for Nasopharyngeal Carcinoma Intensity-Modulated Radiation Therapy
title_full_unstemmed Comparative Study of Auto Plan and Manual Plan for Nasopharyngeal Carcinoma Intensity-Modulated Radiation Therapy
title_short Comparative Study of Auto Plan and Manual Plan for Nasopharyngeal Carcinoma Intensity-Modulated Radiation Therapy
title_sort comparative study of auto plan and manual plan for nasopharyngeal carcinoma intensity-modulated radiation therapy
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7719327/
https://www.ncbi.nlm.nih.gov/pubmed/33293869
http://dx.doi.org/10.2147/CMAR.S226495
work_keys_str_mv AT xinxin comparativestudyofautoplanandmanualplanfornasopharyngealcarcinomaintensitymodulatedradiationtherapy
AT chengchuandong comparativestudyofautoplanandmanualplanfornasopharyngealcarcinomaintensitymodulatedradiationtherapy
AT lichurong comparativestudyofautoplanandmanualplanfornasopharyngealcarcinomaintensitymodulatedradiationtherapy
AT lijie comparativestudyofautoplanandmanualplanfornasopharyngealcarcinomaintensitymodulatedradiationtherapy
AT wangpei comparativestudyofautoplanandmanualplanfornasopharyngealcarcinomaintensitymodulatedradiationtherapy
AT yingang comparativestudyofautoplanandmanualplanfornasopharyngealcarcinomaintensitymodulatedradiationtherapy
AT langjinyi comparativestudyofautoplanandmanualplanfornasopharyngealcarcinomaintensitymodulatedradiationtherapy