Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study

OBJECTIVE: To compare global retinal sensitivity thresholds obtained through the Easyfield perimeter (EF) and Humphrey visual field analyzer (HFA). DESIGN: Observational cross-sectional study. PARTICIPANTS: Glaucomatous patients and glaucoma suspects enrolled between October 2018 and April 2019. MAT...

Descripción completa

Detalles Bibliográficos
Autores principales: Nazareth, Thaissa, Rocha, Janaina, Scoralick, Ana Luiza B, Dias, Diego T, Gracitelli, Carolina P B, Kanadani, Fabio N, Prata, Tiago S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7719433/
https://www.ncbi.nlm.nih.gov/pubmed/33299296
http://dx.doi.org/10.2147/OPTH.S280692
_version_ 1783619678390714368
author Nazareth, Thaissa
Rocha, Janaina
Scoralick, Ana Luiza B
Dias, Diego T
Gracitelli, Carolina P B
Kanadani, Fabio N
Prata, Tiago S
author_facet Nazareth, Thaissa
Rocha, Janaina
Scoralick, Ana Luiza B
Dias, Diego T
Gracitelli, Carolina P B
Kanadani, Fabio N
Prata, Tiago S
author_sort Nazareth, Thaissa
collection PubMed
description OBJECTIVE: To compare global retinal sensitivity thresholds obtained through the Easyfield perimeter (EF) and Humphrey visual field analyzer (HFA). DESIGN: Observational cross-sectional study. PARTICIPANTS: Glaucomatous patients and glaucoma suspects enrolled between October 2018 and April 2019. MATERIALS AND METHODS: All participants underwent EF (SPARK Precision) and HFA perimetry (SITA-Standard). After inclusion, demographic and ocular data were collected, including measurements of retinal nerve fiber layer (RNFL) thickness obtained from spectral-domain optical coherence tomography (SD-OCT). Global indices (mean deviation, MD; pattern standard deviation, PSD) values were compared between perimeters, and their correlation and agreement were evaluated. We used regression analysis to investigate structure-functional correlations between SD-OCT measurements and MD index of each perimeter. RESULTS: We investigated 111 eyes from 69 patients. Mean MD (mean difference=1.49dB) and PSD values (mean difference=0.42dB) from the HFA were significantly larger than those from the EF perimeter (p<0.001). There were significant linear correlations between EF-MD and HFA-MD (r=0.56), and EF-PSD and HFA-PSD (r=0.38; p<0.001). We found significant non-linear associations between average RNFL thickness and MD values derived from both EF (R(2)=0.41) and HFA (R(2)=0.17) perimeters (p≤0.012). A difference <2dB between EF-MD and HFA-MD was found in 53% of the eyes, while 71% of them had a difference <1dB between EF-PSD and HFA-PSD. CONCLUSION: While we found a moderate correlation and a small mean sensitivity difference between test results, EF’s correlation with structural measurements was at least comparable to that of the HFA. Our findings suggest that although these tests should not be used interchangeably, EF SPARK Precision could be used as an alternative for functional assessment in eyes with mild glaucoma.
format Online
Article
Text
id pubmed-7719433
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-77194332020-12-08 Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study Nazareth, Thaissa Rocha, Janaina Scoralick, Ana Luiza B Dias, Diego T Gracitelli, Carolina P B Kanadani, Fabio N Prata, Tiago S Clin Ophthalmol Original Research OBJECTIVE: To compare global retinal sensitivity thresholds obtained through the Easyfield perimeter (EF) and Humphrey visual field analyzer (HFA). DESIGN: Observational cross-sectional study. PARTICIPANTS: Glaucomatous patients and glaucoma suspects enrolled between October 2018 and April 2019. MATERIALS AND METHODS: All participants underwent EF (SPARK Precision) and HFA perimetry (SITA-Standard). After inclusion, demographic and ocular data were collected, including measurements of retinal nerve fiber layer (RNFL) thickness obtained from spectral-domain optical coherence tomography (SD-OCT). Global indices (mean deviation, MD; pattern standard deviation, PSD) values were compared between perimeters, and their correlation and agreement were evaluated. We used regression analysis to investigate structure-functional correlations between SD-OCT measurements and MD index of each perimeter. RESULTS: We investigated 111 eyes from 69 patients. Mean MD (mean difference=1.49dB) and PSD values (mean difference=0.42dB) from the HFA were significantly larger than those from the EF perimeter (p<0.001). There were significant linear correlations between EF-MD and HFA-MD (r=0.56), and EF-PSD and HFA-PSD (r=0.38; p<0.001). We found significant non-linear associations between average RNFL thickness and MD values derived from both EF (R(2)=0.41) and HFA (R(2)=0.17) perimeters (p≤0.012). A difference <2dB between EF-MD and HFA-MD was found in 53% of the eyes, while 71% of them had a difference <1dB between EF-PSD and HFA-PSD. CONCLUSION: While we found a moderate correlation and a small mean sensitivity difference between test results, EF’s correlation with structural measurements was at least comparable to that of the HFA. Our findings suggest that although these tests should not be used interchangeably, EF SPARK Precision could be used as an alternative for functional assessment in eyes with mild glaucoma. Dove 2020-12-02 /pmc/articles/PMC7719433/ /pubmed/33299296 http://dx.doi.org/10.2147/OPTH.S280692 Text en © 2020 Nazareth et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Nazareth, Thaissa
Rocha, Janaina
Scoralick, Ana Luiza B
Dias, Diego T
Gracitelli, Carolina P B
Kanadani, Fabio N
Prata, Tiago S
Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study
title Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study
title_full Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study
title_fullStr Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study
title_full_unstemmed Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study
title_short Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study
title_sort retinal sensitivity thresholds obtained through easyfield and humphrey perimeters in eyes with glaucoma: a cross-sectional comparative study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7719433/
https://www.ncbi.nlm.nih.gov/pubmed/33299296
http://dx.doi.org/10.2147/OPTH.S280692
work_keys_str_mv AT nazareththaissa retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy
AT rochajanaina retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy
AT scoralickanaluizab retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy
AT diasdiegot retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy
AT gracitellicarolinapb retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy
AT kanadanifabion retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy
AT pratatiagos retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy