Cargando…
Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study
OBJECTIVE: To compare global retinal sensitivity thresholds obtained through the Easyfield perimeter (EF) and Humphrey visual field analyzer (HFA). DESIGN: Observational cross-sectional study. PARTICIPANTS: Glaucomatous patients and glaucoma suspects enrolled between October 2018 and April 2019. MAT...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7719433/ https://www.ncbi.nlm.nih.gov/pubmed/33299296 http://dx.doi.org/10.2147/OPTH.S280692 |
_version_ | 1783619678390714368 |
---|---|
author | Nazareth, Thaissa Rocha, Janaina Scoralick, Ana Luiza B Dias, Diego T Gracitelli, Carolina P B Kanadani, Fabio N Prata, Tiago S |
author_facet | Nazareth, Thaissa Rocha, Janaina Scoralick, Ana Luiza B Dias, Diego T Gracitelli, Carolina P B Kanadani, Fabio N Prata, Tiago S |
author_sort | Nazareth, Thaissa |
collection | PubMed |
description | OBJECTIVE: To compare global retinal sensitivity thresholds obtained through the Easyfield perimeter (EF) and Humphrey visual field analyzer (HFA). DESIGN: Observational cross-sectional study. PARTICIPANTS: Glaucomatous patients and glaucoma suspects enrolled between October 2018 and April 2019. MATERIALS AND METHODS: All participants underwent EF (SPARK Precision) and HFA perimetry (SITA-Standard). After inclusion, demographic and ocular data were collected, including measurements of retinal nerve fiber layer (RNFL) thickness obtained from spectral-domain optical coherence tomography (SD-OCT). Global indices (mean deviation, MD; pattern standard deviation, PSD) values were compared between perimeters, and their correlation and agreement were evaluated. We used regression analysis to investigate structure-functional correlations between SD-OCT measurements and MD index of each perimeter. RESULTS: We investigated 111 eyes from 69 patients. Mean MD (mean difference=1.49dB) and PSD values (mean difference=0.42dB) from the HFA were significantly larger than those from the EF perimeter (p<0.001). There were significant linear correlations between EF-MD and HFA-MD (r=0.56), and EF-PSD and HFA-PSD (r=0.38; p<0.001). We found significant non-linear associations between average RNFL thickness and MD values derived from both EF (R(2)=0.41) and HFA (R(2)=0.17) perimeters (p≤0.012). A difference <2dB between EF-MD and HFA-MD was found in 53% of the eyes, while 71% of them had a difference <1dB between EF-PSD and HFA-PSD. CONCLUSION: While we found a moderate correlation and a small mean sensitivity difference between test results, EF’s correlation with structural measurements was at least comparable to that of the HFA. Our findings suggest that although these tests should not be used interchangeably, EF SPARK Precision could be used as an alternative for functional assessment in eyes with mild glaucoma. |
format | Online Article Text |
id | pubmed-7719433 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-77194332020-12-08 Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study Nazareth, Thaissa Rocha, Janaina Scoralick, Ana Luiza B Dias, Diego T Gracitelli, Carolina P B Kanadani, Fabio N Prata, Tiago S Clin Ophthalmol Original Research OBJECTIVE: To compare global retinal sensitivity thresholds obtained through the Easyfield perimeter (EF) and Humphrey visual field analyzer (HFA). DESIGN: Observational cross-sectional study. PARTICIPANTS: Glaucomatous patients and glaucoma suspects enrolled between October 2018 and April 2019. MATERIALS AND METHODS: All participants underwent EF (SPARK Precision) and HFA perimetry (SITA-Standard). After inclusion, demographic and ocular data were collected, including measurements of retinal nerve fiber layer (RNFL) thickness obtained from spectral-domain optical coherence tomography (SD-OCT). Global indices (mean deviation, MD; pattern standard deviation, PSD) values were compared between perimeters, and their correlation and agreement were evaluated. We used regression analysis to investigate structure-functional correlations between SD-OCT measurements and MD index of each perimeter. RESULTS: We investigated 111 eyes from 69 patients. Mean MD (mean difference=1.49dB) and PSD values (mean difference=0.42dB) from the HFA were significantly larger than those from the EF perimeter (p<0.001). There were significant linear correlations between EF-MD and HFA-MD (r=0.56), and EF-PSD and HFA-PSD (r=0.38; p<0.001). We found significant non-linear associations between average RNFL thickness and MD values derived from both EF (R(2)=0.41) and HFA (R(2)=0.17) perimeters (p≤0.012). A difference <2dB between EF-MD and HFA-MD was found in 53% of the eyes, while 71% of them had a difference <1dB between EF-PSD and HFA-PSD. CONCLUSION: While we found a moderate correlation and a small mean sensitivity difference between test results, EF’s correlation with structural measurements was at least comparable to that of the HFA. Our findings suggest that although these tests should not be used interchangeably, EF SPARK Precision could be used as an alternative for functional assessment in eyes with mild glaucoma. Dove 2020-12-02 /pmc/articles/PMC7719433/ /pubmed/33299296 http://dx.doi.org/10.2147/OPTH.S280692 Text en © 2020 Nazareth et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Nazareth, Thaissa Rocha, Janaina Scoralick, Ana Luiza B Dias, Diego T Gracitelli, Carolina P B Kanadani, Fabio N Prata, Tiago S Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study |
title | Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study |
title_full | Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study |
title_fullStr | Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study |
title_full_unstemmed | Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study |
title_short | Retinal Sensitivity Thresholds Obtained Through Easyfield and Humphrey Perimeters in Eyes with Glaucoma: A Cross-Sectional Comparative Study |
title_sort | retinal sensitivity thresholds obtained through easyfield and humphrey perimeters in eyes with glaucoma: a cross-sectional comparative study |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7719433/ https://www.ncbi.nlm.nih.gov/pubmed/33299296 http://dx.doi.org/10.2147/OPTH.S280692 |
work_keys_str_mv | AT nazareththaissa retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy AT rochajanaina retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy AT scoralickanaluizab retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy AT diasdiegot retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy AT gracitellicarolinapb retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy AT kanadanifabion retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy AT pratatiagos retinalsensitivitythresholdsobtainedthrougheasyfieldandhumphreyperimetersineyeswithglaucomaacrosssectionalcomparativestudy |