Cargando…
Evaluation of the Serological Point-of-Care Testing of Infectious Mononucleosis by Data of External Quality Control Samples
Timely and reliable laboratory diagnostics is a necessity for patient safety and good patient management. Success in external quality assessment (EQA) reflects on the everyday work in a clinical laboratory. This study evaluated the reliability of serological point-of-care (POC) testing for the Epste...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7720297/ https://www.ncbi.nlm.nih.gov/pubmed/33328737 http://dx.doi.org/10.1177/1178636120977481 |
_version_ | 1783619821926088704 |
---|---|
author | Kiiskinen, Salla J Luomala, Oskari Häkkinen, Teija Lukinmaa-Åberg, Susanna Siitonen, Anja |
author_facet | Kiiskinen, Salla J Luomala, Oskari Häkkinen, Teija Lukinmaa-Åberg, Susanna Siitonen, Anja |
author_sort | Kiiskinen, Salla J |
collection | PubMed |
description | Timely and reliable laboratory diagnostics is a necessity for patient safety and good patient management. Success in external quality assessment (EQA) reflects on the everyday work in a clinical laboratory. This study evaluated the reliability of serological point-of-care (POC) testing for the Epstein-Barr virus (EBV) that causes infectious mononucleosis (IM). Data from the results of 95 external quality control (EQC) samples, altogether 18 885 results during an eight-year period (2010-2017) were collected from 273 Finnish testing sites. Diagnosing acute infectious mononucleosis (EBV IM) is based on clinical, haematological and serological findings. Heterophile antibody tests are used for this purpose because they can be carried out at POC and are cheap and robust to perform. In this study, the data showed that the testing sites used 3 test methods and 17 different test kits; of the kits, 4 were used during the whole study period. The most commonly used test methods were immunochromatographic assays (12 test kits, 17 959 EQC results). Latex agglutination (4 test kits, 504 results) and immunofiltration test methods (one kit, 422 results) were also used. The overall success rate was 99.3% (for positive samples 99.6%, for negative samples 99.1%). The success rates of the different test methods varied from 94.3% for the immunofiltration method to 99.6% for the latex agglutination method. The lowest success rates were found for negative samples: 82.0% (QuickVue, Quidel [immunochromatographic method]), 91.3% (RDT EBV IgM Assay, Bio-Rad [immunofiltration method]). The results of the negative samples that represented old EBV immunity were the most difficult to interpret with a success rate of 98.9% compared to success rates of clearly positive (99.6%) and negative (99.5%) samples (P < .001). Especially the immunofiltration method (RDT EBV IgM Assay) produced 13.7% false positive results for samples of old immunity. The data showed that 42 of the studied 95 EBV IM EQA rounds were reported as expected (true positive or true negative) by all testing sites. |
format | Online Article Text |
id | pubmed-7720297 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-77202972020-12-15 Evaluation of the Serological Point-of-Care Testing of Infectious Mononucleosis by Data of External Quality Control Samples Kiiskinen, Salla J Luomala, Oskari Häkkinen, Teija Lukinmaa-Åberg, Susanna Siitonen, Anja Microbiol Insights Original Research Timely and reliable laboratory diagnostics is a necessity for patient safety and good patient management. Success in external quality assessment (EQA) reflects on the everyday work in a clinical laboratory. This study evaluated the reliability of serological point-of-care (POC) testing for the Epstein-Barr virus (EBV) that causes infectious mononucleosis (IM). Data from the results of 95 external quality control (EQC) samples, altogether 18 885 results during an eight-year period (2010-2017) were collected from 273 Finnish testing sites. Diagnosing acute infectious mononucleosis (EBV IM) is based on clinical, haematological and serological findings. Heterophile antibody tests are used for this purpose because they can be carried out at POC and are cheap and robust to perform. In this study, the data showed that the testing sites used 3 test methods and 17 different test kits; of the kits, 4 were used during the whole study period. The most commonly used test methods were immunochromatographic assays (12 test kits, 17 959 EQC results). Latex agglutination (4 test kits, 504 results) and immunofiltration test methods (one kit, 422 results) were also used. The overall success rate was 99.3% (for positive samples 99.6%, for negative samples 99.1%). The success rates of the different test methods varied from 94.3% for the immunofiltration method to 99.6% for the latex agglutination method. The lowest success rates were found for negative samples: 82.0% (QuickVue, Quidel [immunochromatographic method]), 91.3% (RDT EBV IgM Assay, Bio-Rad [immunofiltration method]). The results of the negative samples that represented old EBV immunity were the most difficult to interpret with a success rate of 98.9% compared to success rates of clearly positive (99.6%) and negative (99.5%) samples (P < .001). Especially the immunofiltration method (RDT EBV IgM Assay) produced 13.7% false positive results for samples of old immunity. The data showed that 42 of the studied 95 EBV IM EQA rounds were reported as expected (true positive or true negative) by all testing sites. SAGE Publications 2020-12-03 /pmc/articles/PMC7720297/ /pubmed/33328737 http://dx.doi.org/10.1177/1178636120977481 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Research Kiiskinen, Salla J Luomala, Oskari Häkkinen, Teija Lukinmaa-Åberg, Susanna Siitonen, Anja Evaluation of the Serological Point-of-Care Testing of Infectious Mononucleosis by Data of External Quality Control Samples |
title | Evaluation of the Serological Point-of-Care Testing of Infectious Mononucleosis by Data of External Quality Control Samples |
title_full | Evaluation of the Serological Point-of-Care Testing of Infectious Mononucleosis by Data of External Quality Control Samples |
title_fullStr | Evaluation of the Serological Point-of-Care Testing of Infectious Mononucleosis by Data of External Quality Control Samples |
title_full_unstemmed | Evaluation of the Serological Point-of-Care Testing of Infectious Mononucleosis by Data of External Quality Control Samples |
title_short | Evaluation of the Serological Point-of-Care Testing of Infectious Mononucleosis by Data of External Quality Control Samples |
title_sort | evaluation of the serological point-of-care testing of infectious mononucleosis by data of external quality control samples |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7720297/ https://www.ncbi.nlm.nih.gov/pubmed/33328737 http://dx.doi.org/10.1177/1178636120977481 |
work_keys_str_mv | AT kiiskinensallaj evaluationoftheserologicalpointofcaretestingofinfectiousmononucleosisbydataofexternalqualitycontrolsamples AT luomalaoskari evaluationoftheserologicalpointofcaretestingofinfectiousmononucleosisbydataofexternalqualitycontrolsamples AT hakkinenteija evaluationoftheserologicalpointofcaretestingofinfectiousmononucleosisbydataofexternalqualitycontrolsamples AT lukinmaaabergsusanna evaluationoftheserologicalpointofcaretestingofinfectiousmononucleosisbydataofexternalqualitycontrolsamples AT siitonenanja evaluationoftheserologicalpointofcaretestingofinfectiousmononucleosisbydataofexternalqualitycontrolsamples |